DN150 Wafer Type Butterfly Valve BS Standard
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 5000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
General valve using the market long-term, widespread Water Leakage, rust phenomenon, soft sealing gate valve produced by the introduction of foreign advanced technology of the enterprise. To overcome the poor sealing gate valve, general elastic fatigue, rust and other defects. Soft sealing gate valve is a traditional valve replacement products, the compensation effect of using flexible gate produce small deformation, achieve good sealing effect, the valve has a light switch, reliable sealing, good elastic memory and long service life and other significant advantages, can be widely used in water, sewage, construction, food, medicine, metallurgy, electric power, textile, energy systems, fluid pipeline regulation and closure devices as.
The characteristics of:
- flat style seat
The traditional control valve often pass after washing due to foreign objects such as stone, wood, cement, paper, and other debris deposited on the valve at the end of the groove. Close but not close easily lead to the formation of Water Leakage phenomenon, the lower part of the soft sealing gate valve with water using the same flat design, easy to siltation caused by debris, the fluid unimpeded.
And the overall package glue
The valve plate is made of high-quality rubber overall, the outsourcing of plastic, making the domestic first-class rubber vulcanization vulcanization after the valve plate to ensure accurate geometry, and the rubber and ductile iron gate is connected firmly, not easy to fall off and good elastic memory.
And corrosion resistance
The valve body adopts epoxy coating powder, can prevent the corrosion and rust, and can be used for sewage systems.
And not easy to break
Traditional cast iron garden gate often hit foreign objects, collision or overlap caused by the fracture phenomenon. Because the valve to switch to ductile iron, this is the case already significantly reduced.
Three "O" ring seal
As the valve stem with three "0" ring ring seal design, can reduce friction when the switch is greatly reduced, Water Leakage phenomenon and can cut off the water supply construction not replace sealing ring.
And help to drink
Due to the internal body to non-toxic epoxy resin coating, gate of the inner and outer surfaces are completely coated with rubber and can not rust or corrosion of water available to drink.
- Casting valve
Valve body casting, precise geometry makes the body without any internal finishing to ensure that the valve seal.
And light weight
The valve is made of ductile cast, lighter in weight than conventional gate weight about 20%-30%. Convenient installation and repair.
Overview:
General valve using the market long-term, widespread Water Leakage, rust phenomenon, soft sealing gate valve produced by the introduction of foreign advanced technology of the enterprise. To overcome the poor sealing gate valve, general elastic fatigue, rust and other defects. Soft sealing gate valve is a traditional valve replacement products, the compensation effect of using flexible gate produce small deformation, achieve good sealing effect, the valve has a light switch, reliable sealing, good elastic memory and long service life and other significant advantages, can be widely used in water, sewage, construction, food, medicine, metallurgy, electric power, textile, energy systems, fluid pipeline regulation and closure devices as.
The characteristics of:
- flat style seat
The traditional control valve often pass after washing due to foreign objects such as stone, wood, cement, paper, and other debris deposited on the valve at the end of the groove. Close but not close easily lead to the formation of Water Leakage phenomenon, the lower part of the soft sealing gate valve with water using the same flat design, easy to siltation caused by debris, the fluid unimpeded.
And the overall package glue
The valve plate is made of high-quality rubber overall, the outsourcing of plastic, making the domestic first-class rubber vulcanization vulcanization after the valve plate to ensure accurate geometry, and the rubber and ductile iron gate is connected firmly, not easy to fall off and good elastic memory.
And corrosion resistance
The valve body adopts epoxy coating powder, can prevent the corrosion and rust, and can be used for sewage systems.
And not easy to break
Traditional cast iron garden gate often hit foreign objects, collision or overlap caused by the fracture phenomenon. Because the valve to switch to ductile iron, this is the case already significantly reduced.
Three "O" ring seal
As the valve stem with three "0" ring ring seal design, can reduce friction when the switch is greatly reduced, Water Leakage phenomenon and can cut off the water supply construction not replace sealing ring.
And help to drink
Due to the internal body to non-toxic epoxy resin coating, gate of the inner and outer surfaces are completely coated with rubber and can not rust or corrosion of water available to drink.
- Casting valve
Valve body casting, precise geometry makes the body without any internal finishing to ensure that the valve seal.
And light weight
The valve is made of ductile cast, lighter in weight than conventional gate weight about 20%-30%. Convenient installation and repair.
- Q: i want to know where we must use swing check valve and where we must use lift check valve in petrochemical companies. what are the differences ? are they different from the appearance? how can we distinguish between them visually?
- Horizontal Lift Check Valve
- Q: Okay, I got this lawnmower its a craftsman with a briggss and stratton engine, and I use this mower to cut grass in the summer. My question is, I have to get this mower serviced like every 2 weeks. See, the problem is always the valves comes out of adjustment. It only has 2 valves, and a long time ago, I broke one of the studs for the valves. And some guy put another valve on it. Ever since then it hasnt ran good. Iv'e took it many times to get it worked on, and it will run great for about 2 weeks. Then the valves go out it's very hard for it to turn over, and it wont run. Whats the deal here? I hear that you should only have to adjust your valves once a year. What could be wrong?
- i can explain it a bit more personally just email me if you want me to i will be happy to help with this sort of problem!
- Q: What is a valve mismatch in cars. code 300, 302, 420. All togather. Mechanic is telling the truth to do tune up and all. Is iT valve itsef? What is a (bad) coild? MITSUBISHI MIRAGE 2000
- Wherever you are get out. You are about to be ripped off. This will probably be too late. I gather the code you gave is the trouble code, as they are called, from the cars obd. The code 300 is random / multiple cylinder misfire. The code 302 is cylinder # 2 misfire The code 420 is catalytic system below threshold bank # 1 Deciphered this means you have a spark plug misfiring in cylinder #2, bank # 1. The misfire is causing a rich gas mixture in the exhaust system that is detected by the sensor and therefore it says you have a catalytic converter problem. I would suggest you replace your spark plugs, if they have a lot of miles on them. Are they the original plugs ? I f so they are probably due. Get out of there and go find an honest shop that will not rip you off. Now that you know the problem they can;t cheat. I don't know what all that other valve business was about but all you have is a misfiring spark plug.
- Q: 1992 Ford Crown Vic, 102K, burns oil, no blue smoke, no leaks. My first thought was a valve job. Any other possibilities? Suggestions? What about an approxitmate cost for the valve job? Thanks.
- there's a reserve of lubrication placed up the cylinder head; you basically desire somebody to realize up and artwork with their palms till it releases; you need to be slick and arranged very straight away. ought to that fail, they are in a place to continually swap to a crankshift piston rod; at times you basically won't be able to attain back some distance adequate with palms on my own, and you have have been given to get in there with a gadget. you will understand the roles been completed good once you experience the rigidity advance and shrink in alternating waves, and you do not have to any extent further friction subjects.
- Q: Hey guys. I need help. Sorry this might not go here... but i couldnt find a 'good' category to put it in. This is for an engineering project for college.Im looking for shielded core solenoid valves that can with stand 95-98% sulfuric acid. With this in mind not very many materials are usable, right now we are looking for HDPE (High-density polyethylene).The size of the valves and cost is unimportant. Main thing is finding someone who sells HDPE solenoid valves.For more clarification on what we are looking for, below shows a shielded core solenoid valve from ASCO. The more acidic resistant material they offer however is a FKM. Which can only withstand ~60% sulfuric acid solutions.
- In practice, engineers do not use solenoid valves directly on chemical or process lines. They are bound to leak and cause danger particularly in your case of 98% sulphuric acid. Use a mechanical valve actuated by a motor (since cost is no issue to you) If an air supply is available, then you can use pneumatic diaphragm valve operated by a solenoid valve. Motorised valve has slower fixed open close time VS faster adjustable open close time for air operated valves.
- Q: Where is the illusive heater control valve?
- The only valve i could think you are referring too would be the vacuum control on the back of the dash mounted heater controls. They do not have a valve in the coolant lines. The heat turned on or off by a vacuum operated door inside the heater box that merely closes and blocks the heat from escaping into the car. If you are having heater problems first make sure both lines running to the firewall feel hot/warm when engine is at temperature. Secondly you will have to find the actuators under dash on the heater box and make sure they are moving if not ck for vacuum.......
- Q: Do blow off valves serve any purpose besides making the hiss when you shift? how much does one cost?
- Blow-off valves only work on turbocharged or supercharged engines. It is an intake manifold pressure regulator. I've seen people put them on regular engines thinking they would hear that hiss, but there is no where near enough pressure for them to do anything.
- Q: When i was 14 I was diagnosed with a moderate aortic bicusspid valve. I am now 19 at my first cardiologist appointment I was still at moderate. Three months later when i went back in I was rediagnosed with a severe aortic valve. I have every symptom, and I'm getting ready to have it repalced. My question is what am I to expect after surgery. Will i be able to work if not is there anything I can do to have some sort of an income comming in?
- confident you could have continually had this, that's some thing you have been born with. a classic aortic valve is tricuspid, it is it has 3 last flaps, yet a bicuspid valve purely has 2 flaps. sometimes those bicuspid valves provide no issues, yet in some human beings they could bring about coronary heart murmur later in existence ( oftentimes on your 30s or 40s ) simply by fact they permit a sprint blood to leak returned the incorrect way while they are closed. If this gets intense sufficient, you would be able to choose surgical treatment to greater healthful a synthetic valve. that's enormously ordinary those days and not some thing to rigidity approximately.
- Q: I have a D16Z6 SOHC VTEC engine in my 93 Honda Del Sol.Ive been told that the D16Z6 came with 2 different valve covers. One style cover says Honda on the top and another also says VTEC.I have the one that just says honda but I want the other put on.What would I need to swap them, and where would I get them?and a roundabout price
- maybe you can get the cover at your local junk yard. Check and ask around. Since Hondas are so abundant, someone is bound to have it. If not, you can always go to the Honda Dealer. They'll order it in for you the next day. It might be more expensive but it'll be new and they'll be sure to have it. You might also want to check the fit to make sure they're compatable. :)
- Q: I am trying to bench bleed my master cylinder on a 94 altima...the directions state to attach the bleeding hoses to the outlet valves?? I haver four valves that merely state front or rear??
- All hot water heaters have what they call Anode Rods For more than 60 years, it has been used as a key part of the rust protection of a tank. The rods are made of magnesium or aluminum that's formed around a steel core wire and is screwed into the top of the tank. A lot of the times they are on the hot water outlet. You should have a dielectric union separating the galvanized pipe on the top of the water heater from the copper pipe for your house supply. You should be able to remove the anode rod from the tank and get a replacement from your local plumbing supply store. Most likely the sediment/ hard water deposits have deteriorated the rod and have caused corrosive deposits to clog your lines.
Send your message to us
DN150 Wafer Type Butterfly Valve BS Standard
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 5000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords