• DN100 Wafer Type Butterfly Valve BS Standard System 1
  • DN100 Wafer Type Butterfly Valve BS Standard System 2
  • DN100 Wafer Type Butterfly Valve BS Standard System 3
  • DN100 Wafer Type Butterfly Valve BS Standard System 4
DN100 Wafer Type Butterfly Valve BS Standard

DN100 Wafer Type Butterfly Valve BS Standard

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
5000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 



General valve using the market long-term, widespread Water Leakage, rust phenomenon, soft sealing gate valve produced by the introduction of foreign advanced technology of the enterprise. To overcome the poor sealing gate valve, general elastic fatigue, rust and other defects. Soft sealing gate valve is a traditional valve replacement products, the compensation effect of using flexible gate produce small deformation, achieve good sealing effect, the valve has a light switch, reliable sealing, good elastic memory and long service life and other significant advantages, can be widely used in water, sewage, construction, food, medicine, metallurgy, electric power, textile, energy systems, fluid pipeline regulation and closure devices as.

The characteristics of:

- flat style seat

The traditional control valve often pass after washing due to foreign objects such as stone, wood, cement, paper, and other debris deposited on the valve at the end of the groove. Close but not close easily lead to the formation of Water Leakage phenomenon, the lower part of the soft sealing gate valve with water using the same flat design, easy to siltation caused by debris, the fluid unimpeded.

And the overall package glue

The valve plate is made of high-quality rubber overall, the outsourcing of plastic, making the domestic first-class rubber vulcanization vulcanization after the valve plate to ensure accurate geometry, and the rubber and ductile iron gate is connected firmly, not easy to fall off and good elastic memory.

And corrosion resistance

The valve body adopts epoxy coating powder, can prevent the corrosion and rust, and can be used for sewage systems.

And not easy to break

Traditional cast iron garden gate often hit foreign objects, collision or overlap caused by the fracture phenomenon. Because the valve to switch to ductile iron, this is the case already significantly reduced.

Three "O" ring seal

As the valve stem with three "0" ring ring seal design, can reduce friction when the switch is greatly reduced, Water Leakage phenomenon and can cut off the water supply construction not replace sealing ring.

And help to drink

Due to the internal body to non-toxic epoxy resin coating, gate of the inner and outer surfaces are completely coated with rubber and can not rust or corrosion of water available to drink.

- Casting valve

Valve body casting, precise geometry makes the body without any internal finishing to ensure that the valve seal.

And light weight

The valve is made of ductile cast, lighter in weight than conventional gate weight about 20%-30%. Convenient installation and repair.

Overview:

General valve using the market long-term, widespread Water Leakage, rust phenomenon, soft sealing gate valve produced by the introduction of foreign advanced technology of the enterprise. To overcome the poor sealing gate valve, general elastic fatigue, rust and other defects. Soft sealing gate valve is a traditional valve replacement products, the compensation effect of using flexible gate produce small deformation, achieve good sealing effect, the valve has a light switch, reliable sealing, good elastic memory and long service life and other significant advantages, can be widely used in water, sewage, construction, food, medicine, metallurgy, electric power, textile, energy systems, fluid pipeline regulation and closure devices as.

The characteristics of:

- flat style seat

The traditional control valve often pass after washing due to foreign objects such as stone, wood, cement, paper, and other debris deposited on the valve at the end of the groove. Close but not close easily lead to the formation of Water Leakage phenomenon, the lower part of the soft sealing gate valve with water using the same flat design, easy to siltation caused by debris, the fluid unimpeded.

And the overall package glue

The valve plate is made of high-quality rubber overall, the outsourcing of plastic, making the domestic first-class rubber vulcanization vulcanization after the valve plate to ensure accurate geometry, and the rubber and ductile iron gate is connected firmly, not easy to fall off and good elastic memory.

And corrosion resistance

The valve body adopts epoxy coating powder, can prevent the corrosion and rust, and can be used for sewage systems.

And not easy to break

Traditional cast iron garden gate often hit foreign objects, collision or overlap caused by the fracture phenomenon. Because the valve to switch to ductile iron, this is the case already significantly reduced.

Three "O" ring seal

As the valve stem with three "0" ring ring seal design, can reduce friction when the switch is greatly reduced, Water Leakage phenomenon and can cut off the water supply construction not replace sealing ring.

And help to drink

Due to the internal body to non-toxic epoxy resin coating, gate of the inner and outer surfaces are completely coated with rubber and can not rust or corrosion of water available to drink.

- Casting valve

Valve body casting, precise geometry makes the body without any internal finishing to ensure that the valve seal.

And light weight

The valve is made of ductile cast, lighter in weight than conventional gate weight about 20%-30%. Convenient installation and repair.


 


 

Q:I have a Chevy Silverado 2500 5.7L V8. I have been having problems with passing smog. First one failed because it needed a new cat. Replaced it and tested again. NOx emissions are off the chart (1450/1006 max of 992/59615/25mph). I replaced the EGR valve based on a suggestion. Quick test today said the NOx emissions are still way off. Suggested that I change the EGR solenoid valve and also pull the EGR valve and use a coat hanger to clean some of the carbon build up. I purchased a new solenoid today but looking at it I noticed something. Since there are what are appear to be two ports on one side of the solenoid, I must have replaced the vacuum hose onto the wrong one after replacing the EGR valve. How much would this make a difference on the test readings taken? Would it be beneficial to just replace the solenoid anyway or try to test again with the current one but connected properly?
Egr Solenoid
Q:Okay I know lots of people wonder what is better presta or schrader...well I realy don't. My bike was made for presta and thats what I have a question about. So I just got my bike back after is being stored away for a few years, so yeah it was neglected. Question is now that I am doing a tuneup on it I found out the valve came out of the tube. I don't know if that is normal and if I am able to put it back in. It looks like there made for the valve not to come out but I just want to make sure before I go out and buy a new tube. Hope you can help. Thanks. -Sarge
First off, there is no question that presta valves are better! The larger a hole drilled through a rim, the lower its strength. Thus, all other things being equal, a rim drilled for a presta valve will be stronger than a rim drilled for a schrader valve. Tubes with presta valves are slightly easier to pump with a mini-pump than a schrader valve. Finally, they are a bit lighter than a Schrader valve. Secondly, you need to buy a new tube. There is utterly no hope for a repair if the valve comes out. Hope this helps.
Q:I somehow lost the valve cap to one of my tires. Do stores sell replacement caps? If so, would a place like Sears or VIP be a good place to look? If not, would a bike tire valve cap work?In the mean time, i took a cap off the fullest tire to put on this one(the lowest) was that good or bad idea?
The valve cap doesn't prevent air from leaking out; it just protects the valve from dirt and corrosion. Yes, a bicycle cap will work fine, and yes they do sell them in stores. I'd try AutoZone. Even though you won't loose air, replace it. If your valve corrodes, it can get stuck open next time you top off your tires.
Q:ok, after lots of exploring around online and from some great answers from this site I have found the problem to my explorer. The torque converter solenoid mounting clip broke. thats it!! new question, do i have to take off the valve body to remove the solenoid. If so any tips? its way new territory for me. I hate automatics!!
What are you? 9 years?
Q:My pressure reducing valve has gone bad. This looks like a pretty simple change. My question is do i loosen the union nut first (after draining water line), then loosen the whole valve??? Then reverse to install??? Any info would be great....
Yup. That's pretty much it. Loosen the union a little, unscrew the valve from the non union side, then take the union completely loose and remove the valve. Last thing is to remove the other half of the union from the pipe. Always use the complete new union that comes with the new pressure regulator.
Q:1998 Ford Crown Victoria LX 4.6L Use 89 Octane BP, Shell, Chevron gas. When the engine is under stress(acceleration or going up incline) the engine sounds like the valves are chattering. I can increase the rpm's and the chattering goes away. Had the same problem with 95 Thunderbird 4.6 and have heard other ford cars going down the road with this problem. Air leak? Don't really want to use higher octane due to gas prices and possible engine damage. Also, in the thunderbird, i used a bottle of octane boost and the next day a valve spring broke. Was the octane boost a possible cause?
it is not valve chatter, it is called Pinging, it is a fairly common problem, what it is caused by is hot spots in the engine, or by overly advanced spark timing, i would check your base timing, perhaps even back it off a degree or two, i would also run a bottle of marvel mystery oil, or gm top engine cleaner through a vacuum line to burn out the crud that has built up, the sum total of these repairs: about 15 bucks, the savings: your engine! as for your t-bird, it was the pinging that broke the valve spring, not the tank of hi octane. hope this helps
Q:i have a 05 kx250f, new valves recently,will pop start, idle runs high, has compresion, new kckstarter gear but it wont kickstart. someone said the valves need to be shimmed.anybody have any ideals? thanks.
Who okorder /
Q:My Rodeo 96 has a P0440 code (Evaporative Emissions Control System problem). I have visually inspected the hoses on the engine; double-checked the gas cap is tight; but have not looked at the fuel tank sensors and connections. I've noticed that the EVAP canister purge valve solenoid is switching non-stop (click-click-click noise without stopping). Is it the expected behavior?
P0440 Isuzu Rodeo
Q:Is there any treatment available for a leaky heart valve?
This Patient Guide is written for the loved ones of heart patients who are dealing with the short-term stress that comes with a test, procedure or recent diagnosis of heart disease. It explains why support is so important to a loved one with heart disease. It also offers practical strategies on how to support a loved one while also taking care of yourself.
Q:Hi. I looked at instructional videos for installing shutoff valves and instead of simply unscrewing old valve, the plumber simply cut the copper pipe. Is this necessary? Why can't I simply unscrew old shutoff valves from copper pipe?
Most are soldered on and need to be cut off.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords