• XLPE Insulated Power Cable/ Low Voltage XLPE Power Cable 0.6/1KV System 1
XLPE Insulated Power Cable/ Low Voltage XLPE Power Cable 0.6/1KV

XLPE Insulated Power Cable/ Low Voltage XLPE Power Cable 0.6/1KV

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
100 Meters m
Supply Capability:
1000 Meters per Week m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Performance

 

The continuous maximum conductor temperature for operation of the cable is 90°C.

 

The maximum short circuit (not more than 5s) temperature of the conductor is 250°C .

 

The permissive bending radius: if the cable is single core, it is 20 times bigger than outer diameter of the cable. If the cable is multiple core, it is 15 times bigger than the outer diameter of the cable.

 

It should be heated if the laying temperature is under 0°C.

 

Type and Application

 

Type

Name

Application

YJV

YJLV

copper core or Al. core XLPE insulated PVC sheathed power cable

Can be layed indoor and outer door. Can stand a certain tractive force for laying, but can not stand mechanical external force. It is forbidden for laying the cable in magnetic pipe.

YJV22

YJLV22

copper core or Al. core XLPE insulated steel tape armoured PVC sheathed power cable

Suitable for laying underground, can stand mechanical external force, but can not stand strong tensile force

YJV32

YJLV32

copper core or Al. core XLPE insulated steel wire armoured PVC sheathed power cable

Suitable for laying in water or palces with high disperation.Can stand mechanical external force, and a certain tensile force

 

Q: I'm installing a new hard drive and I need an extra power cable. Thing is, I've only got one in my computer (15 pin SATA) I have a spare SATA port for the data, so that's not a problem. Anyone know of any multipliers or some way i can add an extra power cable?Thanks in advance
you are able to split the capacity cable with a a million--to--2 capacity connection. yet you are able to't split an information cable (the flat pink one). you choose yet another cable and a 2d connection on the MB. If no 2d connection, you may get a SATA card to flow in a PCI slot. Have performed the two between the above.
Q: I don't know what kin d of power cord i would need in order to make it work. I thought all monitors needed the same power cable, but im not sure.
You will need a normal Computer Power cable. files.sandberg.it/products/images... look at the back of your computer, and see the cable that plugs into the mains. You will need the very same cable.
Q: or do I need to buy one?
No, the PS3 is a 3 prong outlet cable, and the PS2 is 2 prong. Also the end that plugs into the console is different for both. You can use a PC power cord for the PS3 if needed, the ends are the same.
Q: What are the phone, power, and cable companies in Pomona, Ca?
Verizon for phone SCE (So cal edison) for power Charter? for cable I think. Get Direct TV it's better Gas is So cal gas.
Q: How can we make out the physical size of a power cable if the cable is said to be 4 core, 150 sq.mm ??? How will we measure the diameter of this cable ???? please suggest......
A 4core (electrical) cable of that strength is usually built up from quarter circle shaped sectional wires. (Think of a pizza cut into four even pieces.) So, calculate the outside diameter from this point and add 4 times the insulator thickness. Example: 400V 4core cable has very likely 1mm insulator thickness. 150mm? * 4 cores is 600mm? total. By A=PI*d'*d'/4, d' being the diameter without insulator, would be d'=2*sqrt(A/PI)=600mm?/3.1415...=2*sqrt(...? Now, as said above, add the 4 insulator layers, and then you would be at approx. 31.7mm outside diameter.
Q: I've been looking online for some but can't seem to find some sync cables to strap these amps together. Anyone know where I can find them?
You can use a PS2 male to male cable....kind of like you could use telephone cords from radio shack for the bd remote gain control. $2...plus you'll need a little bit of 8GA wire to tie the amps' outputs together. One gets set to 0 degrees, one gets set to 180 degrees, your gains MUST MATCH, don't do this with power applied anywhere as you'd likely smoke a voice coil. Please know what you are doing, bridging amps is not forgiving and remember each amp is now seeing 1/2 the load, so you could have stability problems if your wired at 2ohms now.
Q: JUST the cable modem and router, not the whole PC. This is for the internet/ phone service.
There's no way of saying without further information. You need to know the amount of power provided by the UPS battery as well as the power drain by the cable modem and router to calculate this accurately. Generally speaking, a standard household model of cable modem and router do not pull a lot of power. Just ballparking it, since the power drain from both is fairly low...A UPS 750 will probably support the two devices together for about 45 minutes to nearly an hour...assuming NOTHING else is plugged into the UPS and using power from it. Be aware, however, that your local ISP will also be on backup or generator power...during an extended outage from a hurricane or serious snowstorm...sooner or later, they will go down too. .
Q: i need to know what kind of cable i need to supply power to my internal dvd player. I ALREADY HAVE AN IDE CABLE
You need a molex cable. Here is a page you can check out to get some 1 to 2 adapters for molex cables. I have ordered things from them before and was very pleased:
Q: What is the difference between a power cable and a cross-linked cable?
If there is a number of casing is the number of lines marked, if the line before the iron circle is a small nose, line nose in addition to a small circle and fork, and fork almost look.
Q: I just finished building my shed, I put a 1 1/2 inch conduit under the shed coming up into the corner. I am now about to dig the 65 foot trench back to the house. I need to run power, not a problem. I want to run a phone line, a network cable, and a cable wire for my satellite. I say shed but it is 12 by 20 feet with an attic. Can I run these additional lines in with the power. I was thinking about using a run of Shielded cables for the network and one for the phone. For the cable some heavy duty quot;I don't know what thoughquot;. Will the power lines mess the data up on them? What will work for the three if any. If I need to I could run them in a new conduit, but that is not cheap!
First, contact the diggers hotline and let them know when you will be digging. They will come out and mark any buried lines with flags. Run the electrical in the proper, approved conduit (to code). Run the phone line in its own conduit. The network and satellite run together in their proper conduit. A few bucks extra is worth it when you realize that the interference on the television is caused by running them all together. Right?
We persist in taking "Technical innovation, service society" as development goal, and "quality-oriented, good faith world" as enterprise idea, trying our best to produce heat-supply products. "Creating the maximum value for clients and providing all-round and round-the-clock service" are our lofty missions.

1. Manufacturer Overview

Location Hunan,China
Year Established 2004
Annual Output Value Above US$100 Million
Main Markets Africa 1.26%
Mid East 0.14%
Domestic Market 98.60%
Company Certifications ISO 9001:2008;ISO 14001:2004;GB/T 28001-2001

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port
Export Percentage
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese
b) Factory Information
Factory Size: 50,000-100,000 square meters
No. of Production Lines Above 10
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords