PVC Insulated Power Cable
- Loading Port:
- China Main Port
- Payment Terms:
- TT or L/C
- Min Order Qty:
- 1000M m
- Supply Capability:
- 1000M Per Week m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Basic Info.
Model NO.: | VV,VLV,VV22.VLV22,VV32,VLV32 |
---|---|
Voltage: | Low and Medium Voltage Cable |
Insulation Material: | PVC |
Current: | AC Cable |
Application: | Industrial |
Export Markets: | Global |
Additional Info.
Trademark: | Taiyang |
---|---|
Packing: | Standard Export Drum |
Standard: | IEC, ASTM, BS, DIN, AS |
Origin: | Henan, China |
HS Code: | 8544492100 |
Production Capacity: | 100km/Month |
Product Description
Electrical cable
1. Used as power transmission & distribution
2. Std: IEC, BS, DIN, NFC, ASTM etc
3. Make up: CU, PVC insulate
The electrical cable(electric cable) is mainly have 2 kinds listing as followings:
1. The PVC insulated PVC sheath power electric Cable
The conductor can be copper or aluminium; Be strands, solid, flexible
The insualtion is PVC
The Jacket/Sheath is PVC
Armored or without armored
Armoured material: Can be steel tape(sta) or steel wire(swa) or others as your request!
The recommended nominal cross section is from 1.5 sq mm to 630 sqmm
The core number can be single or multi
The Voltage is 0.6/1kV
The long-time working temperature of cable should not be higher than 70 celsius
When core is in short-circuit(max 5s) the temperature should not be exceed 160 celsius
While installation the ambient temperature should not be lower than 0 celsius
Type |
Name |
Usage |
VV |
PVC insulated PVC sheathed power cable |
Can be laid at indoor, tunnel and tube .Cable cannot under take mechanism outside force |
VLV | ||
VY |
PVC insulated and PE sheathed power cable |
Can be laid at indoor, tunnel tube and serious polluted places. Cable cannot undertake mechanism outside force |
VLY | ||
|
PVC insulated steel belt armored and PVC sheathed power cable |
Can be laid at indoor, tunnel tube and mining well. Cable cannot undertake mechanism outside force |
VLV22 | ||
VV23 |
PVC insulated steel belt armored and PE sheathed power cable |
Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force |
VLV23 | ||
VV32 |
PVC insulated fine steel wire armored PVC sheathed power cable |
Can be laid at indoor, underground and mining well .Cable can undertake mechanism outside force |
VLV32 | ||
VV33 |
PVC insulated fine steel wire armored PE sheathed power cable |
Can be laid at indoor, underground .Cable can under take mechanism outside force |
VLV33 | ||
VV42 |
PVC insulated thick steel wire armored PE sheathed power cable |
Can be laid at indoor, underground,mining well .Cable can under take mechanism outside force |
VLV42 | ||
VV43 VLV43 |
PVC insulated fine steel wire armored PVC sheathed power cable |
Can be laid at indoor, underground ,mining well and the places of be terrible polluted. Cable can under take mechanism outside force |
- Q:The computer is a Hp compaq.So I took the connector out of the computer but left it in the power socket.When I tried to reinsert the connector I hit the metal back panel of the computer and it made contact so I was wondering what is the part(s) that is likely to be broken?I want to know it so I can replace the damaged parts.Thanks in advance of your help.
- The power cable should have enough rubber/plasitc to stop contact with power supply directly unless you seen a spark I would try the a different cable. Is the power supply turned on? If it did spark and is turned on try swapping the power supply. Actually I missread, it touched the case itself so now you have to start swapping all parts starting with the power supply, then motherboard if that doesnt work. I hope you have some spare parks around. you could also take out the power supply and you will see a long 24-pin connector you can short the 1 green wire with a black one to see if the power supply turns on. The connector is a cable comming from the PSU not on the motherboard. And lastly each time you try to start the computer after swapping somthing only have the essentials to have it start. No CD drive extra HDD etc.
- Q:Due to the large spans the signal must travel it must be amplified or reconstructed at one point, taking into consideration that everything happens underwater, where does the box that reconstructs the signal get it's power.
- Submarine Cable Repeater
- Q:the adapter is fine but the safety pin (the big one) on my power cable broke, do you know where I can buy the power cable for an HP pavilion dv9500 laptop? on the cable it says quot;LS-15 7A 125V LINETEK E70782quot;.also, is it safe to use it although the 3rd pin is gone? it still works but i wouldn't want to fry my notebook...thank you
- Contact HP, this laptop was designed for Vista so more than likely there are no drivers available for xp.
- Q:Recently I bought a EVGA Geforce 8800 GTS. When it came in, the card fits in my case but has 2 cables to plug in. I only have 1 cable to plug them in connected to my power supply. Should i only plug in 1, or is it nessesary? Is there an extra one I just dont know about? Please answer!
- After looking at several 8800GTS's online, I don't see any that require two PCIe six pin plugs. This means I think your talking about the 4 pin molex adapter to be used by those that lack a 6 pin PCIe plug. Because this is a powerful card and it can't get enough electrical power to run from the socket, it needs more juice, and it gets it from the 6 pin PCIe power plug found on newer PSUs. For people that don't have that, many places include an adapter that you can use. If you don't have enough open/free molex plugs however, I question whether or not your PSU has enough power to feed the 8800GTS. What PSU do you have? How many Amps are on the 12V rail? Open your case up and see if you can read the sticker that should be on all power supplies. If you don't have enough open plugs, I would NOT use a splitter. Splitters can be used to hook up several low power devices (like fans) not high power devices like video cards.
- Q:Where can I find a power cable for an HP Photosmart C3180 printer?
- try any big store they carry printer cables, all printer cables are standard if not then go to HP. website look for accessories you'll get one there
- Q:Power cable 5-color line, respectively, what color, what role?
- Copper core cross-linked polyethylene insulated double steel tape armored PVC sheathed power cable, rated voltage 8.7 / 15KV, three core, conductor cross-sectional area of 300mm2
- Q:Ok, my pc and monitor have the same socket for a power cable, and i mixed the two cables up, but one has a 5 amp fuse and one has a 10 amp fuse... What one goes where??
- Depend on the monitor and the pc. Is the pc a laptop? if so it gets the 5 amp. is the the pc a full tower gamer ? then it gets the 10 anp .Same with the monitor is to a old monitor or a new flat screen with powerstar ? See what I mean. It best to call your monitor manufacture or pc to get the right answer. it should not make a big difference but with the cost of a new PC do not take chances.
- Q:I got two hard drives. The cable connecting the hard drive has 2 connectors, does it matter which connector goes to the master drive and which goes to the slave drive? same question regarding the power supply. 2 connectors on the power cable, the order matters?
- it doesn't matter which power cable you use for your hard drive. however, the hdd cable is different story. I am assuming you have EIDE cable. If you just have one hard drive connecting, then it doesn't matter which connector you use. If you have 2 hard drive connecting with one cable, either you have to change the jumper setting so one HDD will be master other one will be slave. Another way is to change the jumper setting on both HDD to cable select; in this case, the hard drive connected at the end connector will be master and the hard drive connected to middle connector will be slave.
- Q:I have recently decided to scrap my capacitor and need and extra two feet of power cable in order for it to reach the amp....is it possible to splice and join two power cables together or is it a better idea to rewire with a longer cord?
- The only way to properly splice the cable is to solder the cable to another piece of cable the same size. The best insulator is brush on tape , just make sure whatever you choose to use, it is sufficiently wrapped. There should minimal power loss if care is taken to make the connection well. However, the best way would be to run a new cable. But considering the trouble this may pose, a quality spice may be the best choice.
- Q:Currently I have a 250GB drive and Writable CD/DVD. I wand to add a 3.51TB internal drive
- you have such a small case, i doublt that there will be room inside the case for another internal drive. if there is room, the PSU should have an extra Sata power connector and you will need to get a Sata cable if you buy an OEM drive, if it's a 'retail' version of the drive then you should get a Molex to Sata power cable and a Sata data cable. you probably wont have space inside the case for another drive, go with a USB 2.0 external desktop drive.
1. Manufacturer Overview |
|
---|---|
Location | Henan, China |
Year Established | 1995 |
Annual Output Value | USD121,752,660.10 |
Main Markets | Southeast Asia;Mid East;Domestic Market |
Company Certifications | ISO9001, ISO14001:2004, OHSMS GB/T28001-2001, CCC |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Tianjin; |
Export Percentage | 70% - 80% |
No.of Employees in Trade Department | 21-50 People |
Language Spoken: | English; Chinese |
b)Factory Information | |
Factory Size: | Above 100,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | High; Average |
Send your message to us
PVC Insulated Power Cable
- Loading Port:
- China Main Port
- Payment Terms:
- TT or L/C
- Min Order Qty:
- 1000M m
- Supply Capability:
- 1000M Per Week m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords