Nominal Cross- sectional Area of Cable | Nomin- allnsul- ation Th- lckness | She- ath Th- lckness | Approx Quter Dl- ameter Ofc- able | Approx Weight of Cable | D.C Realstance of Cable at 20°C | A.C Reals- tance at Operating Temperature | ||||
Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||
mm² | mm | mm | mm | mm | kg/km | kg/km | Ω/Km | Ω/Km | Ω/Km | Ω/Km |
25 | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- |
35 | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- |
50 | 10.5 | 2.2 | 38.0 | 38.0 | 1803 | 1487 | 0.387 | 0.641 | 0.4936 | 0.8220 |
70 | 10.5 | 2.2 | 40.0 | 40.0 | 2070 | 1628 | 0.268 | 0.443 | 0.3420 | 0.5681 |
95 | 10.5 | 2.3 | 42.0 | 42.0 | 2393 | 1793 | 0.193 | 0.320 | 0.2465 | 0.4105 |
120 | 10.5 | 2.3 | 43.0 | 43.0 | 2699 | 1942 | 0.153 | 0.253 | 0.1956 | 0.3247 |
150 | 10.5 | 2.4 | 45.0 | 45.0 | 3052 | 2104 | 0.124 | 0.206 | 0.1588 | 0.2645 |
185 | 10.5 | 2.4 | 47.0 | 47.0 | 3465 | 2294 | 0.0991 | 0.164 | 0.1271 | 0.2107 |
240 | 10.5 | 2.5 | 49.0 | 49.0 | 4092 | 2577 | 0.0754 | 0.125 | 0.0971 | 0.1609 |
300 | 10.5 | 2.6 | 51.0 | 51.0 | 4876 | 2982 | 0.0601 | 0.100 | 0.0788 | 0.1289 |
400 | 10.5 | 2.7 | 55.0 | 55.0 | 5949 | 3424 | 0.0407 | 0.0778 | 0.0615 | 0.1010 |
500 | 10.5 | 2.8 | 57.0 | 57.0 | 7000 | 3866 | 0.0366 | 0.0605 | 0.0487 | 0.0788 |
Oparat- ing Cap- acity | Cable induction | Reactive impeda- nce of Cable | Positive Negative Sequence impedance | Zero Sequence impedance | Short-circuit Current | |||||||
Cu | AL | Cu | AL | Conductor | Screen | |||||||
Cu tape | Cu Wire | Cu tape | Cu Wire | Cu | AL | Cu tape | Cu Wire | |||||
uF/Km | MH/Km | Ω/Km | Ω/Km | Ω/Km | Ω/Km | Ω/Km | Ω/Km | Ω/Km | KA | KA | KA | KA |
-- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- |
-- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- |
0.1150 | 0.6751 | 0.2120 | 0.5372 | 0.8489 | 5.3576 | 1.7680 | 5.6859 | 2.0958 | 7.31 | 4.79 | 1.288 | 3.572 |
0.1263 | 0.6467 | 0.2031 | 0.3978 | 0.6033 | 5.2199 | 1.6171 | 5.4379 | 1.8428 | 10.2 | 6.68 | 1.286 | 3.569 |
0.1368 | 0.6279 | 0.1972 | 0.3157 | 0.4554 | 5.1333 | 1.0577 | 5.2972 | 1.2211 | 13.8 | 9.02 | 1.283 | 5.561 |
0.1460 | 0.6188 | 0.1921 | 0.2742 | 0.3773 | 5.0853 | 1.0075 | 5.2144 | 1.1362 | 17.4 | 11.4 | 1.282 | 5.558 |
0.1563 | 0.5959 | 0.1871 | 0.2453 | 0.3240 | 5.0523 | 0.9704 | 5.1581 | 1.0758 | 21.7 | 14.2 | 1.282 | 5.555 |
0.1665 | 0.5839 | 0.1833 | 0.2231 | 0.2793 | 5.0326 | 0.7156 | 5.1162 | 0.7987 | 26.7 | 17.5 | 1.279 | 7.762 |
0.1805 | 0.5677 | 0.1783 | 0.2030 | 0.2401 | 5.0076 | 0.6863 | 5.0713 | 0.7496 | 34.6 | 22.6 | 1.278 | 7.756 |
0.1945 | 0.5540 | 0.1740 | 0.1906 | 0.2165 | 4.9922 | 0.6667 | 5.0433 | 0.7145 | 43.1 | 26.2 | 1.277 | 7.751 |
0.2146 | 0.5395 | 0.1694 | 0.1802 | 0.1972 | 4.9928 | 0.6519 | 5.0324 | 0.6912 | 57.4 | 37.6 | 1.274 | 7.730 |
0.2321 | 0.5272 | 0.1655 | 0.1726 | 0.1833 | 4.9830 | 0.6398 | 5.0131 | 0.6698 | 71.7 | 47.0 | 1.273 | 7.726 |
- Q: My laptop battery ran out because my power cable broke. I need to take out my files before I get it repaired. Is there a way I can charge my laptop? (HP Pavilion Entertainment)
- Sounds like you just have to buy a new cable.
- Q: What are the causes of the power cable fire accident? How to prevent
- Notebook does not have the opportunity to DIY. The reasons are as follows: Notebook motherboard non-versatile motherboard, the shape of the motherboard, positioning holes, screw holes are not uniform standards, each manufacturer's motherboards are their own engineers and then open factory production model. Notebook shell corresponding to the interface location, type and screw hole location is with a specific motherboard supporting.
- Q: Hi all, I'm moving into a new apartment August 1, and I'm wondering how far in advance I need to call the power company, cable company, etc to set up service. I know this is probably a dumb question, but throughout college I moved into apartments where at least one of the other roommates was staying (I took over someone's lease who was moving out, but the other girls stayed so I was the only new resident). But I'm moving into a one bedroom, and I've never had to set these things up before so I just thought I'd ask what the standard time frame is. Is a month enough advance notice--should I start setting this stuff up in early July? Or sooner? Again, I know this is probably dumb but I have no experience so I wanted to ask some people who've been there and done that what the procedure is. Thanks in advance!
- You okorder to compare electricity and cable or satellite rates. The cheaper the rate the less you pay :) I have personally never had to pay a deposit even when I was in college. They check your credit for outstanding balances on utility bills and base your deposit if any on that.
- Q: I want to buy a 2nd power cable for a 22Hanns-G PC monitor (hg221a) but do not know what or where to buy one - any pointers
- This is a standard item. Go to an electrical/electronic/computer shop with the old one.
- Q: So i left my xbox on over night (i know i know) and during the night there was either a power outage or surge, cuz all the electronic clocks had been reset. So i went to my xbox, and the light on the power cable box was red and my xbox wouldnt turn on. I havent tried unplugging it yet cuz the wires are behind my tv and a pain in the *** to get to, but i have a feeling this wont help.do i need to get it repaired?
- The power brick is shot. Same problem happened to me. Best solution is to call xbox support and ask for a replacement. They'll ship one to you,the only problem is that sometimes they will charge you and sometimes they won't.
- Q: what kind of power supply cable plugs into the hard drive?
- Which okorder /
- Q: i wanna know how much distance should be in between the power cable and the cat5 cable
- standard used to be 185 feet somewher 100 meter ,I am not sure what you mean by to power ......
- Q: if found the reistance then what are the acceptable limits such that replace the cable or repair the cable
- See the document by Megger on how to determine if a cable is good and much more. This is a very good document that covers both static (insulation hipot testing) and TDR fault location methods.
- Q: I am planning on buying new power and ground cables for my car system. How much would it cost for 4gauge wire? and how much would a fuse for that cost? -my system is about 1000w
- when okorder
- Q: Hey guys I have a compaq sr5550f desktop the power light under the cable is flicking green but the computer will not turn on or off yesterday it was fine but unable to connect to the monitor I have saying no signal? whats up with it it was fine two days ago I unplugged all cables and let it rest and still the same result even if i unplug all the cables it still flickers green the dies off then if i plug it back it does it again help?
- hi: All solutions above talking approximately battery backup are almost comparable, yet with differing terminology. the object you choose is definitely referred to as an Uninterruptible potential furnish. APC is a sturdy sort. I even have 2. to boot to protecting the laptop from potential outage, they help shelter against potential line spikes. besides the shown fact that, they do no longer often final for hours, in ordinary terms a jiffy (10 to 30, counting on load). A united statesthat keeps your laptop on for a pair of hours could value you over a $one thousand money (US). an excellent one which will artwork for a jiffy, offering you with lots of time to shutdown if the potential is off for a whilst, will run decrease than $one hundred. i've got seen them for extra or less $40. There ought to be some much extra decrease priced. a extra effective plug strip isn't the respond. you are going to be making use of a united stateswith a pc besides... Too undesirable they are no longer purely offered with them! LOL Cheers!
Send your message to us
26/35kv single-core XLPE insulated PVC sheathed power cable(YJV,YJLV)
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords