• 0.6/1KV,low voltage,XLPE insulated,aluminum conductor,power cable System 1
  • 0.6/1KV,low voltage,XLPE insulated,aluminum conductor,power cable System 2
  • 0.6/1KV,low voltage,XLPE insulated,aluminum conductor,power cable System 3
0.6/1KV,low voltage,XLPE insulated,aluminum conductor,power cable

0.6/1KV,low voltage,XLPE insulated,aluminum conductor,power cable

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
200 m
Supply Capability:
20000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

0.6/1kV XLPE Insulated Power Cable
The cable meets the standard requirements of GB/T12706-2002 or IEC60502-1997.

0.6/1kV XLPE Insulated Power Cable

1.Standards
The cable meets the standard requirements of GB/T12706-2002 or IEC60502-1997. It is suitable to be installed in the power line with rated voltage of 0.6/1kV U0/U (Um).


2.Type, Designation and Applications

TypeDesignationApplicationsYJVYJLVCu or Al conductor XLPE insulated PVC sheathed power cableFor laying indoors, in tunnel and in ducts. Able to bear certain traction during laying but not external mechanical forces. Impermissible to lay single core cable in magnetic ducts.YJV22YJLV22Cu or Al conductor XLPE insulated PVC sheathed internal steel tape armored power cable.For laying indoors, in tunnels, in ducts and underground. Able to bear external mechanical force but not large pulling forces. Impermissible to use single cable in A.C. circuit.

 

3.Specifications

TypeNumber of coresNominal Cross-sectional Area(mm2)YJV YJLV11.0~630YJV YJV22YJLV YJLV2221.0~400YJV YJV22YJLV YJLV2231.0~400YJV YJV22YJLV YJLV223+14.0~400YJV YJV22YJLV YJLV2241.0~400YJV YJV22YJLV YJLV2251.0~400

4.Using properties
1.The maximum rated temperature
The maximum operating temperature of cores shall not exceed 90°C when the cable is used for long period. The temperature of cores shall not exceed 250°C at short circuit for 5 seconds.

2,The installation of cables is not limited by the difference of level along the route. The ambient temperature should not be below 0°C during installation. The permissible bending radius for cable shall not be less than 10 times of the cable diameter. The single cable shall be without amour or with steel wire amour when it is electrified with alternating current and shall not be laid in magnetic ducts.

5.Technical specifications


Rated voltage of cable

0.6/1kV

D.C. resistance of core

According to GB/T3856-1997 or IEC228A-82

Power frequency withstand voltage test for 5 minutes(KV)

No breakdown at 3.5kV

Hot set test for insulation, 200°C 15min with pressure 20N/cm2

Maximum elongation values at load

175%

Maximum permanent elongation values after being cooled

15%

Power frequency withstand voltage test for 4 hours, not break down

2.4


6.Technical parameters
YJV, YJLV 0.6/1kV

Q:i have pentium iii cpu.unexpectedly i disconnected my power cable from power button.the power cable consists four color(red,black,white,blue) and in my power button it has four(p1,p2,1,2) pins.i don't know which colour is opt with this pins uld you plz help me...
Find out the make/model of your motherboard. Go to the motherboard manufacturer's website and download the user manual for your motherboard. In this manual there should be a page (or pages) illustrating where the various headers and connectors are on your motherboard.
Q:ok so i'm building a high gaming computer. my question is i'm a getting a Full moduler power supply my question is do i have to buy the cables for power does the componets i buy come with them??? oh and by the way just curious what happens if you touch thermal paste with your finger???
Your power supply will come with a standard assortment of cables to supply power to various components ASSUMED to be in your system. But you will want to read reviews of your chosen power supply before you buy it to find out what (specific) cables are included. Most modular power supplies will have the right cables for motherboard and hard drives and optical drive. The connections you need to pay attention to are the PCI-Express cables. High-end video cards will need at least one power connection. Some video cards need TWO power cables for EACH card. If you plan to run multiple cards, you could need 4, 6 or even 8 PCI-Express power cables! So you need to think ahead to decide how many (maximum number) of video cards you will want to install in the system. Then figure out what specific model. Then add up the number of PCI-Express power cables needed by type. Such as: (2) six-pin plus (2) eight-pin. Now you are ready to read reviews of your chosen power supply to see if it has the right cables included. Thermal paste often contains heavy metals. So it's not good to touch it with your finger. But momentary contact is not a problem, as long as you wipe it off and/or wash your hands shortly afterward. The main problem with touching thermal paste (with finger or otherwise) is that you don't want to remove too much of it from the heatsink/CPU area...or it won't cool properly. In general, don't touch it with your finger. But if you do, it's not a big deal. Just don't leave it on your skin for very long.
Q:I removed the seats to my 2002 Dodge Intrepid SE and noticed that there was a small cable sticking out from the carpet underneath the seats. Since I have the SE model my car didn't come with the power seats. My question is are those cables there to attach the power seats?
Yes, all wire harnesses are made to serve the power needs of all possible options rather than building different harnesses for each individual car.
Q:I was looking at buying the MSI HD6850 cyclone OC/power edition but on the msi website it says it includes an external power cable. Am I missing something? Do I need more than the standard pci-e 6 pin connector from the PSU?
Some graphics cards require you to connect a power cable to the board. As it requires more power than it can get through the pci connection.
Q:Hi I have a 94 Cadillac Deville 4.9L and im trying to figure out with cable on my alternator is the power cable and which one is the ground. I have included a pic to help.
The power cable is the fat one.
Q:How do power-station-cable thieves manage to get away without being electrocuted?
Police are hunting for a badly scorched would-be copper thief after finding a hacksaw embedded in an 11,000 volt power cable. The thief also left a lit blow torch at the scene. He is presumed to be badly charred, and not the brightest bulb in the socket. .
Q:Where can i find the power cable for this specific TV brand ? GO-VIDEO-2050..?
Most TVs use two different types of power cable with either a normal female end or a two-prong narrow female end. Go to Best Buy and most likely you can find what you need.
Q:When I plug and unplug a power cable to the net in my home for let's say, 50.000 times a day, why doesn't my electricity-meter not count that power for the monthly electricity fee?When I unplug the cable the cable should still have some electricity flowing through it at the moment of unplugging. That electricity disappears very shortly after . But after unplugging it, it doesn't have any electricity anymore. So some electricity is lost right? How does this work?
Basically, the appliance works on the current flowing into it. When you unplug the cable (or hit the OFF switch, same thing) the current stops flowing, then the appliance then stops working. Very simple. .
Q:ive recently opned my external harddrive case so that i could put dat harddrive in my pc ... i was able to take out the ide cable but i cnt take out the power cable... plz help me.. how can i take out the power cable?
try using a pair of plyers and moving the connector side to side while pulling
Q:I need to know if the power light on the amp will turn on if I don't have the RCA cables hooked up or if you have to have them hooked up just to get power to the amp? I was just wondering because I just hooked up an amp and I can't get the power to come on, and I'm pretty sure the power, ground, and remote wire is hooked up good, it's the RCA cables i'm thinking is messed up, but would the power light come on even if those wasn't hooked up?
If you have the amp hooked up without rca cables thats where the problems coming from

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords