• WQ Series Sewage Vertical Centrifugal Pump System 1
  • WQ Series Sewage Vertical Centrifugal Pump System 2
  • WQ Series Sewage Vertical Centrifugal Pump System 3
WQ Series Sewage Vertical Centrifugal Pump

WQ Series Sewage Vertical Centrifugal Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Product Introduction 

WQ series submersible sewage pump is mainly used for municipal work, industrial building, hotels, hospitals, civil air defense, mines, etc. It can be widely used in transfer waste water, rainwater and living water etc. which contains solid grains and various long fibers CNBM WQ series sewage submersible pump have many advantages, such as, hi-efficiency, circumvolution proof, blockage free, auto-coupling, hi-reliability and auto-control, etc.

 

2. Technical Performance 

1). Discharge diameter: 50~600 mm

2)  Capacity: 10~8000m³/h

3)  Head: 5~60m

4)  Power: 1.5~315kw

5)  Diameter of pass solids: 20~145mm

 

3. Operation Condition 

1). Rated Voltage: 380V(660V), Frequency: 50Hz, 3-phase AC.

2). Temperature of medium under 40ºC.

3). PH value: 4~10.

4). Volume ratio of solid in medium below 2%.

5). Density of medium should be lower than 12000kg/m³.


4. Impeller Design Characteristics 

For the feculence pass freely, it must be widen the flowing passage of impeller, for the big pump, can used for double-vane, or three-vane, for the small pump, it used for single(double) flowing passage, like a bent pipe has same section, it has a good passing characteristic, avoid stop, convolve caused by slowing current possibly. The especially flowing passage of impeller, cooperate with logical volute, made the paper, soft goods, garbage bag and other material in sewage can passing freely and the pump have no vibration in the course of running-in and load through the impeller balance between dynamic and static state.

 

5. FAQ

1) How can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2) Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3) Do you have self-priming pumps?

Yes, our product portfolio also includes two ranges of self-priming pumps: self-priming electric pumps and self-priming side channel pumps.


 

WQ Series Sewage Vertical Centrifugal Pump

WQ Series Sewage Vertical Centrifugal Pump



Q: I would like to ask the river for about 70 degrees on the steep slope pumping 170 meters, flat 40 meters into the pool, what should I choose water pump? How many heads? How to choose the water pump model? Thank you
70 degrees or so on the steep slope pumping 170 meters, vertical height of about 100m, you can choose the lift 120-150m of multi-stage pumps, nominal diameter 1 inches, 2 or 1 inches and a half can be.The power consumption of about 1520kW.
Q: If a submersible pump to shake the insulation, water pump distance more than 20 meters away from the cable distribution box is fixed, at this time to shake the insulation in the distance distribution box can only shake, disconnect the power cable is connected with the shake table, the ground end is connected with the distribution box in such a shake, I want to ask is, what is this shake is not the pump shell must be reliable grounding to shake ah? Now the pump casing is not grounded, just immersed in water, immersed in the water, is not equal to good grounding ah?
A submersible pump to shake the insulation, water pump distance more than 20 meters away from the cable distribution box is fixed, at this time to shake the insulation in the distance distribution box can only shake, disconnect the power cable is connected with the shake table, the ground end is connected with the electric box so that the pump shell shake shake, also must be reliable grounding to shake to now, the pump shell grounding not only in the water, it must be a wire connected with a shell or a wire will be immersed in water, this is right insulating shake,
Q: What are some good brands of aquarium water pumps? I have had bad experiances with Hydor Seltz (cheapest ones I could find, ugg, I know, you get what you pay for) pumps, failing very quickly, and sounding like plastic gears grinding around inside. What is the best kind to get?I need one that's around 150gph
PowerHead? or Sump Pump? I have used hagen aquaclear powerheads on my saltwater tanks for years 24/7 without a problem. I just purchased 3 MaxiJet 1200 powerheads and a wave timer to see haw they do, 6 months now 24/7 and so far so good. The longest lasting Sump Pump that I have ever owned is made by Ehime, I've had it for 14 years now and it's still going in one of my tanks. I better cross my fingers on that one.LOL
Q: A Pump is direct driven by a 25 HP 900 rpm electric motor at rated load. In order to to double the quanitity of water delivered, it would be necessary to substitute a motor rated at____HP at____rpm. ans. 200 and 1800. not sure how they came up with this answer...whats the equation???
N = (95 H.C)/D Where N = rev/min D = diameter of impeller over blade tips in metres H = total head in metres C = constant. C depends on the shape of the pump and normally lies between 1.05 and 1.2 Later edit. I'm not sure if you are aware of it but each impeller has it's own characteristic performance curve.
Q: Our water pump was really warm/hot to the touch, our hot water was more warm than hot, and wouldnt heat up enough to get hot, and it wouldn't turn off. (like when it starts up when you turn on the water,it just kept going,and wouldn't stop) so, because it was hot, and going constantly, we didn't want it to explode, or burn out, so we turned it off, and now I'm hoping that when we turn it back on after it cools, that it'll go back to turning on/off intermittently, instead of constantly. So, after it cools down, will it go back to normal, instead of just constantly going??!?
I assume you have a water well pump. The experience I have had, is it will come back on once the thermal safety switch cools down. However, I think you still have work here to do because each time this happens, you are shortening the life of your pump. First you need to determine why it ran hot to begin with. Could be lots of reasons, but just to name a few. -Is your water tank in good shape, with the correct air pressure? -Is the tank waterlogged, too old or leaking? -Any leaks in the service in or to the house? -Is your contact switch working properly, clean contacts, good wire, good connections, breaker etc.? -Is there water running somewhere your not aware of? -Last but not least, the check valve and foot valve leading to the well could also be defective. Just my opinion, I hope this helps to get you thinking. Good luck; flip;
Q: Does anyone know or can show me a picture of the location of the water pump in the '97 Totota avalon please? I'm trying to replace mine.Please and Thank you :)
The water pump is commonly driven either by the pump drive belt or the timing chain/belt. It is easy to replace the belt-driven water pump, as it can be remove from outside of the engine. For the timing chain/belt driven water pump, you need to remove the front cover and belts before you can reach the pump. Drive your car to the nearest dealer workshop and ask the mechanic.
Q: I just had my water pump/timing belt replaced and oil change. When the pump failed, white smoke was coming out, which I figured out to be coolant from the smell. Now there is smoke coming out from under the engine, which I believe to smell like oil. Also, the temperature gauge goes up to the halfway point when I am at a stoplight or idling. The highest I have ever seen it is at 1/3.I had my car serviced by the dealership and I asked them. The man said its burning oil residue from the oil change and that it will burn away in a few days. Is this true? I have had my car worked on and oil changed for the past year at this dealership and have never had any smoke or other problems. What else could be going on? Worse case scenarios. Thanks everyone.
Looks like you should have went ahead and bought the Volkswagen now don't it?
Q: It stops and every few minutes and when it stops, it sounds like water is running.
A car will not shut off and not start again if the water pump has leaked and the engine over heats to the point of seizing. But if the pump has just started leaking then know the engine stall. As for the park issue again not related.
Q: 37KW how many contactors does the pump need to start directly?
Direct start requires 250A contactor.Contactor is divided into AC contactor (voltage AC) and DC contactor (voltage DC). It is applied to power, power distribution and power consumption. Contactor broadly refers to the use of coils in industrial electricity that flow through the current to produce a magnetic field, so that the contacts are closed so as to control the load of the appliance.
Q: Okay, i have a 1997 dodge stratus with a 2.4l motor, recently i was out early in the morning when i heard what sounded like a loud whining noise, i quickly pulled over and killed the motor. Turns out the teeth were stripped off the timing belt and the water pump busted. How much would this cost to get it fixed, and what is the possibility the engine may be damaged? Also would it be worth fixing it, or just selling it for parts? Oh yeah, the car has 176k miles
Non- interference engine.Meaning no damage. repair it. 100% guess here Parts: Pump / T-belt / Tensioner,Coolant - $140 your cost -200 shop Labor : 3 hours/Or free rate of difficulty 1--10 -5-

Send your message to us