PVC Insulated Power Cable
PVC has been in use as an insulating and outers heating material for a long time. Since PVC has some degree of flame retardance, and resistance to oils and chemicals, it has found many suitable applications including low power and control uses. Generally, they are two types of PVC, general purpose and heat resistance PVC with maximum conductor temperatures of 70℃ and 90℃respectively.
PVC Insulated cables are used in power distribution, building wire, appliance wiring, flexible cord and machine tool wiring. Insulation and jackets made from PVC have a number of desirable properties that make them the insulation and jacketing material of choice for many common applications. These properties include flexibility, resistance to temperature, resistance to adverse environmental situations and low cost.
PVC insulated cables can be manufactured both armored and unarmored, including one with reduces neutral conductor and a phase-to-phase voltage of 1000 volts. The conductor used in mainly plain annealed copper, other conductors such as tinned copper and aluminum are also available and may be supplied upon request.
Introduction of our company
Our company is a professional China Wire and Cable Manufacturers, mainly supply Aerial bundled cable,House Electric Wire, Insulated Overhead Cable,Aluminium Conductor Steel Reinforced, PVC Control Cables,XLPE Power Cables,BV Electric Wires,Nylon Sheathed Cable,Buried Cable,High Voltage Cable,House Electric Wire,Single Core Flexible Copper Cable,Civil Wire And Cable etc. series of wire and cable products, sincerely welcome everyone to visit.
- Q: I have bought a 1.5 ton window AC from Blue Star recently and used 2.5 sq mm cable to power it through a 16A DP MCB.Can the load be supported in this scenario?
- 1790 watts at 230 volts is about 8 amps. I would use a power cable rated for at least 10 amps or more. You would need a wire of about 8.3 sq mm, 1.63 mm diameter, or 14 awg to run this load. 2.5 sq mm is the equivalent of 24 awg wire, 0.5 mm diameter, or rated for at 3.5 amps. The unit couldn't draw enough current to run properly with this wire.
- Q: Just wondering if the eVGA GT 440 graphics/video card needs a power cable connect from the psu to it.I bought a PC pre-made from JB HI-FI and going to upgrade my graphics card. The one I have currently is the Radeon HD 4650 and it appears to have no cable connecting to it. There are however, some cables connecting to the motherboard near it.
- No, it doesn't need one, but it's also a crappy purchase. The Radeon 6670 costs about the same, doesn't require external power, and slaps the GT 440 silly.
- Q: I was replacing the hard drive of my desktop computer but now I don't know where the cable [see picture] fits. it obviously goes somewhere since the computer does not turn on now. The Hard Drive is SATA if relevant. Thank you!
- That's the main power connector for the motherboard. It probably plugs into that white socket behind it on the board, but check the motherboard manual to make sure you put it in the right place. It's pretty hard to plug things into the wrong place most of the time, but check to be sure.
- Q: I want to buy a 2nd power cable for a 22Hanns-G PC monitor (hg221a) but do not know what or where to buy one - any pointers
- This is a standard item. Go to an electrical/electronic/computer shop with the old one.
- Q: trying to install new amplifier; running cable from battery through firewall to the trunk; done on several cars before; looking for advice or best practices...
- if you look under the hood, facing the cars windshield, the far right corner against the firewall, there's a dip in the sheet metal. if you drill there at the lowest point, the hole will come out behind and a little above your brake pedal. run it through there , under the side trim. not only will this seperate power from rca wires (eliminating ground noise) but it will be easy to run. if you want a professional job, take out your seats (all of em) and run it under the carpet, but i'm sure you have to remove the center console. my buddy ran the wire under the car and drilled through the floor and ran it under the rug but that is such a bad idea because if the wire corrodes from weather you will have a fire.
- Q: best buy geeks advised me to buy wd320sata h/d to replace seagate barracuda 7200 h/d....... cannot connect .... no sata connector on motherboard that i can find....... instructions says need power cord. any suggestions????????? please and thank you.........
- The SATA specification demands 7 pins to flow archives. Conveying potential to gadgets demands heavily greater desirable potential throughput than conveying archives. potential adapters have been redesigned for SATA gadgets from usual Molex to make it as common to plug and unplug because of the fact the recent SATA archives cables. The redecorate made the pins smaller. With electrical energy bypass with the aid of potential conduits, travelling electrons inevitably hit the molecules of the conduit itself, which excites the molecules and the molecules launch this further potential as warmth. once you're attempting to maintain an identical bypass of electrons over the years yet shrink the actual length of the conduit (as develop into finished with the SATA potential spec), an identical variety of electrons could desire to bypass interior the path of the conduit over the years yet with the aid of a smaller pipe. This focused 'site visitors' leads to greater collisions, ensuing in greater desirable warmth output from the steel conduit. with the intention to have the smaller pipe and an identical quantity of site visitors without overheating the steel conduit to the factor the place it burns the plastic housing, you may desire to have greater of the smaller pipes turning in that site visitors. think of of it like highway site visitors. in case you may desire to make a highway smaller, the site visitors that already traverses that highway will now could desire to deal with one yet another for that narrower thoroughfare. with the intention to maintain site visitors shifting and forestall site visitors jams, you may desire to construct further roads to accommodate that exact same site visitors quantity. only area of this analogy that would not correlate is that electrons do no longer decelerate once you're piping them with the aid of a smaller conduit.
- Q: Whether high voltage cables can be built in belt corridors
- Electric workers in the wood when the wood bar, buried in the soil that part of the first use of fire char, and then brush into the ground after the bitumen
- Q: What kind of material does the power cable accessory contain?
- First of all, it should be noted that the short circuit is caused by the current is too large, short circuit occurs when the short-circuit current will be very large, can not be used to describe how many times, and electrical design to consider the wire cross-sectional area will not be great, Heat, so the conductor will be hot
- Q: What is the difference between the power cable yjv and the vv cable? In the use of what to pay attention to? What is the difference between selection? Online ~~~ more
- According to the project to see how much current, according to the current selection cable thickness, and then choose to embed more rough casing, embedded casing is to cable alignment
- Q: printer is powered on. cables are securely connected. printer has ink and paper. printer installed as network printer on all client computers. other users are able to print to the printer. but printer not working on the other computer
- go to computer that can print to the printer, click start, click printer and faxes and note share name and ports. then go to printer that does not print, click start, click printer and faxes... if printer is shown, compare with the other computer if printer is not shown, click add printer (wizard pops up) using info from other computer that can print. btw, go to printer manufacturer website, download and install latest software/driver to computer that does not print. good luck!!!
Send your message to us
High quality PVC Insulated Power Cable with a good price
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10000 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches