Product list of China Engine type Generator FX50
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 1000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
1.Jichai diesel generator
2.Optional alternator
3.long-term spare parts
4.low fuel consumption
5.economic price
1100kw/1375kva Jichai Reliable Diesel Generating set
Engine features :
1.China most famous brand diesel engine: Jichai engine
2.Multi-cylinder in-line or veer engine,4 stork,direct injection
3.Naturally aspirated,turbocharged,water cooled or turbochaged with air intercooler.
4.Machinery or electronic governing
5.Fuel injection pump
6.Electric motor starting system
7.Forged steel crankshaft,cast iron cylinder and replaceable wet type cylinder liner
8.Low discharge,and low fuel consumption
9.Installed conveniently and maintain easily
Alternator Features:
1.World famous brand AC alternator:Leroy Somer,Stamford,Marathon.Engga ect.
2.Brushless,4 poles,rotation magnet
3.IP21-23 enclose is standard for all industrial alternators.
4.H class insulation system
5.AVR self-regulated,voltage regulation rate:±1%
6.Simple installation and maintenance with easy easy access to terminals ,rotating diodes and coupling bolts.
7.Moisture proof,sand-proof,dustproof ,salt-proof and vibration-proof.
Control system:
1.a) Automatic alarm system:the unit has the acousto-optics alarm system and arrestor for any situation as the start defeat,the water is over temperature,
the oil pulls down ,over speed,over load and over current.
b) Operation display:
i)Unit voltage,tri-phase load current and frequency display
ii)Water temperature .oil pressure display
iii)Fuel level, fuel temperature display
iv)Audible and visual alarm lamps and buzzers
2.Starting system:DC alternator is used to start engine.
3.Short circuit protection :MCCB air switch
4.Cooling system:combined cooling water tank fitted to meet the requirement of radiation at ambient
temperature 40°C
5.Filter system:oil ,fuel and air filter
6.Accessories:exhaust elbow,below,muffle
Model | Output POWER(KW) | Engine Model | Engine Power | |
PRIME | STANDBY | |||
FX50 | 45 | 50 | SC4H95D2 | 62/68 |
- Q:I want to shut it inside a small room, but will it not suffocate ? Which part of the gen set should be moved out of the room ?
- The size is relevant. Is this a small portable set for homes, or a large stationary unit for a building. I'll assume the latter. Enclose it in a sound barrier, but bring the exhaust out the top and make an air inlet at the bottom that goes to the air intake of the engine. You may need additional openings for ventilation to keep the engine from overheating. You may be able to bring the radiator outside the enclosure to solve that problem. Make sure you have a very good muffler. Look into finding a better one. You may be able to buy an enclosure for the generator, check with the manufacturer. PS, you seem to have this located indoors. That is a very bad idea.
- Q:about diesel generator
- Water cooled is hydrolic obviously and it don't really go faster depends what horse power the engine or motor is. Air cooled is just your basic diesal that need a spark to start and needs air to cool down.
- Q:i go to UTI get the diesel technican program were could i get a joband what would be the starting wageshow much would i make a yearthanksp.s i would eithier work in texas or california
- If U learned a skill see which industry is needed for what u want to do.UTI should have jobs lined up.
- Q:From what I understand, when the earthquake struck, the nuclear reactors had shut down (control rods were inserted). As a result, the power coming from the steam turbine generators were shut off.At the same time, the earthquake had knocked out Japan's power grid, so power coming from outside the power plant was out.Then the emergency diesel generators went into effect, but was knocked out an hour later as well, and people suspect it was from the tsunami.Would the disaster still have happened if they kept the steam turbine generators running (which means never shutting down the reactor via control rods), and water pumping, instead of shutting it down and letting the backup power direct the emergency cooling?
- if hte control rods had not be inserted it would of catastrophic. the reactors would be working at 100% and no one can shut it down becasue there is no power. left for too long and unable to stop the reaction, it could lead to an actual meltdown like at the Chernobyl. there's a good reason why during any emergency the control rods are inserted. its standard protocol since the very first nuclear reactor experiments back in the late 1930s under some gym in the eastern USA. you want to shut down the most dangerous thing first, the one that has the most potential for catastrophe before doing anything else.
- Q:can somebody explain to me electrical power distribution for jackup rigstarting from the engine to generator then bus,MCC1,MCC2,SCR
- Nice to have your Q, i am also a Jack up Rig Design Engineer. Ok. see 1st of Jackup rigs have diesel generators which provide power supply for the various electrical power requirements on rig. usually the voltage level is 6.6kV, 4.16kV, 690V or 600 V which is then further reduced upto 415V, 220V/127V as per load and client requirements since it affects the design and overall space required and size of rig as well. the generated power is 1st transferred to the main PMCC or MCC known as generator switchboards. from here the power is dirtributed to various other switchboards such as jacking MCC, drilling MCC, Ventilation MCCs, VFD panels (for top drive mud pump panels through VFD/SCR system) and other MCCs for other electrical loads. voltage is further reduced upto 415V/220V/127V for lighting and other lv loads using dry type transformers. oil filled trafos are not preferred since they r bulky and not feasible to have them on rigs since its in sea and also problem in maintenance. cables used are usually of XLPE or XLPO insulation. the configuration is as follows CU/XLPE or XLPO/Inner sheath (SHF)/Armour/Outer sheath (SHF), the inner and outer sheath has to be low smoke halogen free material, armour is usually bronze wire armour, usually cables used are all flame proof as per iec 60332, cat 3-22A and cables for emergency purposes are fire resistant as per iec 60331. hope this is fine.
- Q:I want to calculate the Genset load of following 3 phase, 50 C/s, 400/ 440 volts electric motors coupled with Water pumps.60 HP x 4 Nos. + 100 HP x 3 Nos. + 225 HP x 3 Nos.What is the method for calculating the safest load for all these motors to run simultaneously.
- You are after capacity of the generator not load. You add up all the power required: 240 HP + 300 HP + 675 HP 1215 HP 1 HP 746 W Power required 906.39 kW You take this figure in consideration to choose your set allowing for efficiency and power factor.
- Q:How to shut off the diesel generator
- If you press the red emergency stop button, you must return to the original position, otherwise the generator will not be able to start.
- Q:How to convert kVA (kilo-volt Ampere) to kg/h (kilogram per hour) for diesel generator set (genset)? I want to know the relation about the energy produced (kVA) to the fuel that used (kg/h) in the genset, either it used more diesel fuel or not. i.e the kVA amount produced is 106kVA and the rpm is 1500rpm
- You cannot convert between different types of units. KVA is a unit of power. kilogram per hour is a flow rate. What you are asking is for formula for the efficiency of a diesel generator in terms of energy delivered per liter or kg of fuel, and that is a function of the diesel design, and maintenance. In other words, it can be measured, not calculated.
- Q:I need a silent diesel generator of power capacity of 25 kW, i am going for the following brands(suggest something)1. Jackson Cummins2. Mahindra powerol3. Kirloskar
- i have seen Kirloskar unit in an office complex. Seems to be good. No idea about the other two brands.
- Q:Elec. bill is too high, so I wanna run 2HP swimming pool pump via generator. It's 240V. How big a generator do I need? Is diesel less to purchase than gas? Is diesel cheaper to run? Can I run the pool say 6 hrs a day on generator designed for emergency back-up?
- A generater of a 3600 watt capasity ought to work. the choice of engine to drive it is your choice
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Product list of China Engine type Generator FX50
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 1000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords