Specifications

open type dioesel generator with yuchai enginee 
1) Factory direct sale 
(2) CE, ISO9001 quality 

Power range

18-650KW

Engine

All series powered by Yuchai engine

Alternator

All series owning alternator options of Stamford/Marathon/ENGGA

Controller system

Hanging control box, automatic control module Smartgen HGM6310

Base frame

International channel steel welded base, inbuilt composite damping system; sandblast, acid-washing, antiseptic treatment

Radiator

Standard genset-joining radiator of 40 °C ambient temperature

 

 

Diesel generator Powered by Yuchai Engine,which yuchai is a large state-owned enterprise and a Nasdaq listed company in USA (NYSE:CYD). Its main business covers diesel engine, contruction machinery, vehicle parts. The engines produced by Yuchai include series YC6G, YC4G, YC4E to which American technology applied, series YC6A, YC6B, YC6J, YC4B, YC4D, YC4F, YC4W to which German technology applied, and YC6M series in which world top technology integrated, totally 12 series.

YUCHAI SeriesPower(KW)Power(KVA)Jichai Engine ModelCylinder NO.Fuel consumption
g/kw.h
DimensionL*W*HWeight  
 KG
FKS-Y700700200YC6G245L-D206≤1952500*970*15002300


Q: and diesel generator and ATS that switches between two electrical sources ??
There may be no difference. It will depend on the application. For example, if I specified an ATS that had the proper voltage and current capacities, the only other item of concern would be to determine if the transfer would be a make before break or a break before make type of transfer. In a make before break, it would mean the sources would be placed into parallel operating condition before one of the sources was interrupted. This would require the ability to synchronize the sources. Which means the frequency, voltage and phase relationship of the sources must match before they are placed into parallel service. On a break before make switch, usually only phase rotation and approximate voltage levels are of concern. Hope this helps, Newton1Law
Q: i would like to get the machine that is at least 2000 0r 3000 kw
I'll assume you have a typo in there and you really need only 2 kW! Are you looking for something with 120/240VAC or 120VAC only? Do you plan to install a transfer panel or connect with extension cords as needed?
Q: I need the information to do a science project - how is this electrical energy stored?
It's funny you should ask because I was just researching the wind energy subject while looking at getting a job with a company that makes generators. Generally I've found that it isn't! Wind power is usually expected to be supplimental to the power grid because you can't depend on it 24/7. The only exceptions to this are remote areas where they have no power grid access and even then they usually have diesel generators too. I have seen small ones on sailing boats where I'm sure it just tops up their batteries. Waste byproducts are zero or even negative. I say negative because in a lot of places the excess power is fed back into the power grid reducing the need for the other power stations to pollute as much. In fact the only bad things I've heard are from those that think they are an eye sore, those that think they are noisy (which generally are not) and those that think birds will crash into them. it's funny that they don't complain about the glowing ones that nest at my local nuke generating plant tho ;o)
Q: Have a 15kw generator. Diesel. I want to upgrade without buying a whole new generator. Can I keep the motor and swap a generator hook up
My best suggestion would be upgrade to Solar Photo Voltaic where you get output and also save diesel+ environment. or buy a second hand D.G .
Q: An electrical power system consists of identical diesel generators, each generator. Has a constant failure rate of 0.5 per year. Calculate the reliability of the following arrangement-three months after the initial commissioning date. 1. Only one generator operating. 2. Only generator operating, one generator standby. 3. One generator operating, two generators standby.
Mark T, ia on the component of the mark. every time you alter reason tension, like from reciprocating engine to equipment field, you lose a number of that tension.and the comparable holds real with electric loss. in case you have battery's and are utilising them to go a automobile or boat, the great capability available is used quickly. subsequently an engine will recharge or a minimum of save the drain decrease, giving longer variety in a automobile. the project with boats is that's like hiking up hill all of the time, there are no longer any downhill runs that shrink the capability intake, subsequently electric capability for boats is extremely constrained, like WWII submarines of direction in case you have Nuclear capability you may circulate as long as you like, interior the layout shrink of the propulsion unit. Edit. WWII submarines had an exceptionally constrained in velocity and variety jointly as under battery capability. some thing like 4 knots an variety of 50-60 miles. in the event that they tried 8 knots they could no longer circulate very far. actually they ran on the exterior the two throughout the time of the day and at nighttime.diving purely whilst ships approached. they could make 17 knots on the exterior, so they might attempt to get previous to a convoy, then dive and anticipate the convoy to return to them. The Batteries returned then the place no longer almost effective as on the instant's batteries.
Q: Did some searching, and found little other than single, model specific, manuals (either paper or on CD). The paper manuals are $50-60 each. Single model PDF manuals on CD are about $20.Does anyone know if a comprehensive set of shop service manuals is even available for Yamaha Portable Generators? (gas and diesel) I don't mind paying, but I don't want just ONE manual, I want 'em all. That way I don't have to go through this again when a different model Yamaha comes into my shop. TIA for any help!:-) ?
floor directly to the physique, and run your cord to a robust earth floor. those areas are obtainable at your community electric supply that sells living house-wiring factors, you will want a floor rod, clamp, and a few sturdy copper cord.
Q: Electrical Engeenearing
A diesel power plant is a stationary installation incorporating one or more diesel generator sets with controls and switchgear. Diesel plants are usually used as emergency backup systems for military installations, hospitals, and other vital installations that depend on reliable electric power. There are also diesel power plants that are the only power supply for remotely located installations and communities; for example, remote radar stations and island resort towns. In a diesel plant, there are one or more diesel generator sets, consisting of a diesel engine and a suitable generator. A typical arrangement would involve three generators of which any two can handle the peak load while the third can be held as a standby unit or dismantled for major maintenance at intervals. There will be a switchyard that contains the electrical contactors and safety devices for connecting the generators to the grid as needed, and there will be control panels for the individual generators, as well as synchronizing gear to keep the generators in phase. In many installations these controls are computerized and can be operated and monitored at a distance over the internet or other communications arrangement. Also, there will be arrangements for handling the fuel required by the engines. Often there is a large tank and separate day tanks for each engine. This type of arrangement helps ensure that the entire supply is not lost in case the fuel plumbing or day tank for one generator set springs a leak.
Q: I have a Kubota GL7000 portable diesel generator. now I've followed the recommended maint. schedule on it, new fuel filters, oil filters, oil changes, etc. I have just under 1,000 hours on it right now, it smokes a little when it's cold but when it warms up it runs nice and smooth and with no smoke, it seems to me that it's running really solid and I have no complaints or problems, but I'm curious how long a generator like this (2 years old) should last me?
Just give it a lot of love and it'll last a real long time. haha And when it dies, get another. Don't worry about it.
Q: can you also tell me the functioning of those parts. thank you.
I think you mean diesel-electric generator. Properly, a diesel generator is a factory that makes diesel fuel. And the parts (at a high level, as there are thousands of parts total) are a diesel engine, plus fuel tank. an electric generator or alternator and electronic and mechanical controls to adjust the engine and generator so that it outputs the required voltage and frequency as the load changes.
Q: Im currently working on a DC generator design . I have my output set to 3000 kw . Any idea what's the usually assumed voltage for this rating ?
I believe that DC generators in this size range have been used in diesel-electric locomotives. Today, locomotives are designed with AC drive systems, so there isn't much information about design for DC systems. I found a little bit of Information that indicates that generators of this size may have been designed to operate at about 1200 volts. Edit-1 The 1200 volt design may have been an AC generator with a rectifier connected to two 600 volt DC motors connected in series. The largest DC generators may have been 600 volt machines. Large DC generators were also used in Ward-Leonard drives in steel mill applications and other large industrial applications. It appears that these may have been 600 volt machines. In any case, applications for DC generators began to be converted to AC generators with silicone rectifiers as soon as high-power silicone rectifiers became available in the late 1950's and early 1960's. Today, working on a large DC generator design would seem to be pointless except as an academic exercise. Even the value of such an academic exercise seems questionable.