• Factory price china yuchai diesel generator sets 430kw System 1
Factory price china yuchai diesel generator sets 430kw

Factory price china yuchai diesel generator sets 430kw

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
300 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

open type dioesel generator with yuchai enginee 
1) Factory direct sale 
(2) CE, ISO9001 quality 

Power range

18-650KW

Engine

All series powered by Yuchai engine

Alternator

All series owning alternator options of Stamford/Marathon/ENGGA

Controller system

Hanging control box, automatic control module Smartgen HGM6310

Base frame

International channel steel welded base, inbuilt composite damping system; sandblast, acid-washing, antiseptic treatment

Radiator

Standard genset-joining radiator of 40 °C ambient temperature

 

 

Diesel generator Powered by Yuchai Engine,which yuchai is a large state-owned enterprise and a Nasdaq listed company in USA (NYSE:CYD). Its main business covers diesel engine, contruction machinery, vehicle parts. The engines produced by Yuchai include series YC6G, YC4G, YC4E to which American technology applied, series YC6A, YC6B, YC6J, YC4B, YC4D, YC4F, YC4W to which German technology applied, and YC6M series in which world top technology integrated, totally 12 series.

YUCHAI SeriesPower(KW)Power(KVA)Jichai Engine ModelCylinder NO.Fuel consumption
g/kw.h
DimensionL*W*HWeight  
 KG
FKS-Y430430200YC6G245L-D206≤1952500*970*15002300


Q: Frequency meter
A frequency meter may have different meanings to people in different fields, though they are related. In electrical situations there are the vibrating reed types seen of generator power boards. These are simply connected across the mains like a voltmeter. These indicate when the mains is close to the desired frequency. They help with setting the RPM of a diesel generator. In radio and electronics applications it is more likely to be called a frequency counter. It has a digital counter, a frequency reference and a time base counter. It measures frequency by counting the input signal for a specific time. They are often able to measure time intervals too. These can be very precise, especially using precision external references. Connections. Connect to the signal to be measured as appropriate, so for lower frequencies the connection is something like an audio cable with clip leads. This can load the circuit under test. A divide by 10 oscilloscope probe is useful to reduce this loading. Frequency meters for higher frequencies like VHF, UHF and microwave often have a 50 ohm input, and are designed to be connected via a coaxial cable, terminated at the input of the instrument. There has to be an arrangement to tap power off the device being measured. Safety Precautions. The most important safety precaution is to keep the voltage or power at the input to a level that will not cause damage. The lower frequency types may have a voltage rating, and the 50 ohm types have a power rating. A suitable kind of attenuator is needed if the voltage/power is too high.
Q: I have a small one bed one bath home probably not over 1000ft what size portable honda generator should I buy?
add up the wattage of the appliances you want to run and get a generator a little bit bigger. the size of the house is not the issue. the issue is what do you want to run power to.
Q: I want to buy 5000kva diesel generators from the manufactuerer?
google them and then find out there requirements - very simple .
Q: I want to place a quiete genarator which is about 7kva. Will it disturb people in my apartment? We usually make a lot noise in the building. But doesn't sound a lot also?
a 7kva generator isnt even that quiet. i know they say quiet but theres only so much you can do. why do you need a generator anyways? and yeah it probably would disturb the people in your apartment.
Q: Fuel tank is for generator and its a day tank the size of the tank filling line is 2
The reason is to minimize the static Electricity
Q: Could anyone tell me what would be the price of 1 megawatt generator head (alternator). Also which are the major companies producing it in India?
Generators don't have heads. A 1 MW unit might cost around USD75,000.- equivalent in a 2 pole configuration although, not being responsible, I certainly don't guarantee that number. Try Tata, Aakar Group, Prakash Diesel, Genex Electronics Industries.
Q: Fanks for answering!
Advantages: We can set up breeder reactors that generate electricity as well as plutonium. This plutonium can then be used to make nuclear weapons to drop on hostile terrorist nations. Disadvantages: The whiny environmentalists that riot and protest even though they owe their existence to nuclear power as the Atomic Bomb put an end to WW2. ------------------wikipedia----------- Advantages of nuclear power plants against other mainstream energy resources are: * No greenhouse gas emissions (during normal operation) - greenhouse gases are emitted only when the Emergency Diesel Generators are tested (the processes of uranium mining and of building and decommissioning power stations produce relatively small amounts) * Does not pollute the air - zero production of dangerous and polluting gases such as carbon monoxide, sulfur dioxide, aerosols, mercury, nitrogen oxides, particulates or photochemical smog * Small solid waste generation (during normal operation) * Low fuel costs - because so little fuel is needed * Large fuel reserves - (e.g., in Canada and Australia) again, because so little fuel is needed * Nuclear Batteries - (see SSTAR) Disadvantages include: * Risk of major accidents - an example of the worst possible situation is what happened to Chernobyl Nuclear Power Plant (which did not have a conventional containment building) * Nuclear waste - high level radioactive waste produced can remain dangerous for thousands of years if not reprocessed. * Can help produce bombs - all designs of reactor can produce plutonium, aiding nuclear proliferation (see Magnox) * High initial costs * High energy inputs during construction (equivalent to ~7 years power output) * High maintenance costs * Security concerns * High cost of decommissioning plants * Thermal pollution (although all power plants emit thermal pollution)
Q: I understand that it powers your stuff. But how does it get power? How long can it run before losing it's power? Please no physics, just a simple answer. Thanks!
simple words But how does it get power? it makes its own, to share with you, it turns a fossil fuel into electricity How long can it run before losing it's power? until its fuel is gone (depending on the size of the fuel tank, rough measure is 8 hours on half load on its tank of fuel)
Q: I have a generator in the building I am working on. It appears quite dated, but its stats are as follows: it’s a 415 Volt 3 Phase Diesel Generator.On the plate of the generator:415V3 Phase640KVA520KWPower Factor 0.8902 AmpsSo my question is:We are testing the generator to its full load, now my load is at power factor 1. Would I be correct in assuming that because my load is power factor 1 that the full load of my generator is 640kW not 520kW.Or is it that my actual power loading is rated at 520kW, but that load is allowed to be inductive or capacitive to 0.8.Because it says 900 amps on the plate I am therefore under the assumption that regardless of my load characteristics, as long as I do not exceed 900 amps there should be no problem. Or is it a case that my load can only be 520kW and the highest I can allow the phase to go out is up to 640kVA.Hope that makes sense, ill edit if not. Thanks for reading.
Treat all of the figures as maximum rated outputs. The maximum power it can delivery is 520kW, that is why it says 520kW. 640kVA and power factor 0.8 should not be be exceeded either but if your load is pf1 then the 520kW will take precedence. No offence but anyone who can't interpret these numbers shouldn't really be testing equipment of this power.
Q: Hi. I need to buy a diesel generator to run my house on. We have to run at least 3 ACs at a time. The ACs consume roughly 1500W with a surge power of 4500W.Here's my question. If I get a 12KW rated generator, does that mean that each phase can only handle 4000 KW, therefore not even enough to start an AC? i was given this formula by a sales man KVASQRT3 X V X iCan you shed some light on this problem?Greetings from Iran
Is the house wired 3 phase or split phase or single phase? Very few houses are wired for 3 phase power. Iran uses 230/240 VAC 50Hz So from that, you need a single phase 240 VAC 50 Hz generator. A 12 kW generator at 240 volts would supply 50 amps. I'd run that to a breaker panel (if you don't already have one) and then run 10 amp lines with a 10 amp breaker to each AC. That leaves you with quite a few amps to run other appliances. You got off on a 3 phase tangent for some reason you aren't telling, but I don't think that is the way you want to go. hope that helps. .

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches