ESP End Suction Single Stage centrifugal Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 500 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Introduction of ESP End Suction Single Stage centrifugal Pump
Without any crane equipment, no matter whether the motor power big or small, one person can replace the motor bearings and mechanical seals within 20 minutes.
General description of ESP End Suction Single Stage centrifugal Pump
ESP,Series New Hi-Tech Centrifugal Pumps are designed to resolve the present single stage centrifugal pumps high failure rate in the market, such as leakage of Mechanical seals, noisy of motor bearings, Bearings over temperature when running …etc, if the mechanical seals or bearings need to be replaced on site, usually it is limited by space and crane equipments, especial for the big motor unit, it is no way to remove the motor and have to lift by hands depending on many manpower , or have to build tripod, it is very inconvenient and easy to damage the workers and equipment if failure.
Technical data of ESP End Suction Single Stage centrifugal Pump Model meaning of ESP End Suction Single Stage centrifugal Pump
Capacity:Q:80 - 1600m3/h
Head:H:8 - 125m
Max Working Pressure: 1.6MPa
Max Operating Temperature: 120℃
Rotation Direction : from the driven end, the pump rotating direction is CW
ESP、 250 – 400 A
ESP ----- ShenBao New Hi-Tech Horizontal Centrifugal Pump
250 ---- Discharge Diameter (mm)
400 ---- Impeller Nominal Diameter (mm)
A -----Impeller Trimmed Code
Application of ESP End Suction Single Stage centrifugal Pump
Chemical, foods and drink , metallurgy, petrochemical, pharmacy, firefighting, , high-building, air-condition cooling system, paint, HVAC, pulp and paper, electric power, irrigation, water treatment and all kinds of applications.
FAQ of ESP End Suction Single Stage centrifugal Pump
1. Are CNBM pumps available in DIY stores?
Yes, currently, we’re available for DIY stores all over the world.
2. Where do I have to send pumps for service?
You must send them to the CNBM PUMP Service Point or, after contacting Customer Care, to the CNBM PUMP service center in China.
3. Are your pumps acid-proofed?
To choose the right pumps for chemical applications, we do need further details on hydraulic operations as well as on the type, concentration and temperature of the liquid.
4. Can your pumps mount Eff.1 motors
Currently, only on request though this will shortly be a CNBM standard.
- Q: I have a 1986 Camaro and it is overheating. Thermostat was changed and fan is working. When it over heats it doesnt loose any coolant. Hoses are hot. I dont see any white smoke. No milky oil. Car runs good except sluggished going up hills. Dont see any leaks. I have notice that a water pump I replaced 2 years ago is all rusted on the outside. Could that be a bad pump? Why would a water pump rust on the outside?
- Water pumps have no protection so over time they rust, as do other underhood parts. NEVER replace any part 'till you KNOW the problem. You need to visit a RADIATOR SHOP and have your radiator looked at. Water pumps don't cause overheating, radiators do.
- Q: I need a water pump for a 1930 Chrysler Roadster and have no idea where to get one. Any suggestions?
- Thanks for the plug Howard! Although the Imperial club does not sell or distribute any parts, there are some good resources and tips there. What I do recommend is that you buy a copy of Hemmings and look up some of the services out there that are water pump specialists. Your water pump is a very unique one in that it probably has not been available since WWII. So careful rebuilding of the original one in your car is key.
- Q: coolant leaking from weep hole on water pump need to know what i need to remove to replace or should i call mechanic
- Take an autoshop class.
- Q: water pump
- Flow? Head? suction pressure? Type of pump if that matters to you? You'll get better suggestions if you provide as much information as is relevant.
- Q: I need to fit a booster pump to increase pressure from a gravity fed vented solar water heater (uses vacuum tubes).The problem is that the temperature of the water from the solar panel can be very high - in fact it could boil under some circumstances. It's safe because the system is vented.As the quot;solarwater feeds existing water heaters in the house, diluting the hot with some cold prior to the pump with an automatic mixer valve is not really an attractive option as we want to gather as much hot water as possible.Can anyone tell me where to get a booster pump that can operate at up to 100 Deg C, delivering 2 bar pressure and about 25 liters per minute. Thanks.
- Yes you can as per the other answer . Make sure when you do you dont exceed the Gallons per minute of the cellar pump or you will burn up the pump on your house . Also make sure that the pump in your moms house can only pump up to 50 psi . Most well pumps can pump higher but that is the setting on the presure switch You might be able to change the tank and switch in moms cellar to a bigger presure tank and up the presure on the presure switch and cure the problem that way and not work the well pump so hard by turning off and on so often .
- Q: I drive a 2003 Mitsubishi Outlander and I am required to change my timing belt as part of preventive maintenance. When I had been to Firestone, they quoted $998 for Timing Belt Water Pump (both parts labor). When I called Midas, they quoted $550 for the same. Does anyone know why there is such a big difference? I have been a regular at Firestone, so Midas is new to me. Are they reliable? Midas is quoting low now, but would there be a surprise charge after I get it done? BTW, how is a water pump related to a timing belt??
- For the best answers, search on this site https://shorturl.im/ayg4o Replacing a water pump may or may not be correct, if it's not leaking or noisy then it is still serviceable. The issue is more of a preventative maintenance issue. It will likely fail, and when it does, you must remove all the parts involved with the timing belt job to access it, so you incur the labor cost twice. I recommend a water pump be done at the second Timing belt or around 120K miles, if not done sooner. also the tensioner pulley/s at that time as a safety practice, some engines use hydraulic tensioners that are prone to failure (early mitsu's). There is no way of saying how long the water pump will last, and when it does fail, it's usually an inconvenience.
- Q: After I replaced the water pump impeller in my outboard I fired up the motor and now its not pumping any water through the pee-hole at all and also the prop is spinning in the neutral position (motor seems as if it is in gear and trying to move). Would this be because of the shift rod or the drive shaft not being in the proper position and possibly the impeller is being span the wrong in the impeller housing cup?
- i am no expert on outboards. i did put an impeller on one with the same problem. no water output. seems there was a tube, that ran from the pump to the cylinder head. it was cracked, and the water couldnt reach the cylinder head. seems that the impeller shaft should always turn in the right direction, or it wouldnt cool in reverse, if you got this far , i am sure you will figure it out. you must be a pretty good mechanic to get that far,,
- Q: Can I use Ultra Blue gasket maker on a water pump? The packaging is not labeled high heat.
- Yes, but you have to let the gasket maker cure for at least 24 hours. After you have driven it for a couple days, be sure to re-tighten the flange bolts, as the gasket maker will shrink with heat, causing possible leakage. Good Luck !
- Q: We had a thunderstorm followed by power outage last night, this morning I went to use the water and it slowly went dead.I began by inspecting the pressure tank and pressure control switch, then found the outside water pump breaker was tripped, upon resetting the water was back on!But wait, after about 1-2 minutes of use there was a small quot;POPand smoke from the control switch and the breaker tripped again. It seems now that every time the water pump kicks in I've got a 50/50 shot of the circuit breaker blowing. I'm not sure what to do now, I don't want to keep resetting my pump breaker, we really didn't get that much rain so I don't know what would be causing this issue?Any help would be greatly appreciated.Thanks!
- Water Pump Trips Circuit Breaker
- Q: Domestic pump does not use water, or turn, I do not know why?
- The motor should be kept working, may be the motor switch problem, idling motor pump long time will certainly be bad, ha ha, the solution is to find a water pump maintenance master to work safety first!
Send your message to us
ESP End Suction Single Stage centrifugal Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 500 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords