Water Cooled Perkins Genset Diesel Generator 40kva With Heavy Duty Engine
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Water Cooled Perkins Genset Diesel Generator 40kva With Heavy Duty Engine
Quick Detail:
1.Perkins Industrial Heavy Duty Engine
2.24V DC Electric motor starting system
3.AVR self-regulated, voltage regulation rate: ≤±1%
4.Deepsea 7320 Control Panel
5.220v/380v,230v/400v,240v/415v
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRP10 | 7 | 9 | 8 | 10 | 403D-11 | ≤252 | 3 | 1.131 | 77*81 |
GNRP15 | 10 | 13 | 12 | 15 | 403D-15 | ≤264 | 3 | 1.496 | 84*94 |
GNRP23 | 16 | 20 | 18 | 23 | 404D-22 | ≤243 | 4 | 2.216 | 84*100 |
GNRP33 | 24 | 30 | 26 | 33 | 1103A-33G | ≤210 | 3 | 3.3 | 105*127 |
GNRP50 | 36 | 45 | 40 | 50 | 1103A-33TG1 | ≤212 | 3 | 3.3 | 105*127 |
GNRP65 | 48 | 60 | 52 | 65 | 1103A-33TG2 | ≤211 | 3 | 3.3 | 105*127 |
GNRP73 | 52 | 65 | 58 | 73 | 1104A-44TG1 | ≤207 | 4 | 4.4 | 105*127 |
GNRP88 | 64 | 80 | 70 | 88 | 1104A-44TG2 | ≤213 | 4 | 4.4 | 105*127 |
GNRP103 | 75 | 94 | 82 | 103 | 1006TG1A | ≤210 | 6 | 5.99 | 100*127 |
GNRP150 | 110 | 138 | 120 | 150 | 1006TAG | ≤205 | 6 | 5.99 | 100*127 |
GNRP165 | 120 | 150 | 132 | 165 | 1006TAG2 | ≤205 | 6 | 5.99 | 100*127 |
GNRP225E | 165 | 206 | 180 | 225 | 1306C-E87TAG3 | ≤220 | 6 | 8.7 | 117*136 |
GNRP250E | 180 | 225 | 200 | 250 | 1306C-E87TAG4 | ≤219 | 6 | 8.7 | 117*136 |
GNRP259E | 188 | 235 | 207 | 259 | 1306C-E87TAG5 | ≤221 | 6 | 8.7 | 117*136 |
GNRP275E | 200 | 250 | 220 | 275 | 1306C-E87TAG6 | ≤223 | 6 | 8.7 | 117*136 |
GNRP344E | 250 | 313 | 275 | 344 | 2206C-E13TAG2 | ≤201 | 6 | 14.6 | 137*165 |
GNRP388E | 280 | 350 | 310 | 388 | 2206C-E13TAG2 | ≤198 | 6 | 14.6 | 137*165 |
GNRP450E | 320 | 400 | 360 | 450 | 2206C-E13TAG3 | ≤201 | 6 | 14.6 | 137*165 |
GNRP500E | 360 | 450 | 400 | 500 | 2506C-E15TAG1 | ≤216 | 6 | 15 | 137*171 |
GNRP550E | 400 | 500 | 440 | 550 | 2506C-E15TAG2 | ≤211 | 6 | 15 | 137*171 |
GNRP625E | 450 | 563 | 500 | 625 | 2806A-E18TAG1A | ≤196 | 6 | 18.13 | 145*183 |
GNRP700E | 508 | 635 | 560 | 700 | 2806A-E18TAG2 | ≤203 | 6 | 18.13 | 145*183 |
GNRP800 | 580 | 725 | 640 | 800 | 4006-23TAG2A | ≤199 | 6 | 22.921 | 160*190 |
GNRP900 | 640 | 800 | 720 | 900 | 4006-23TAG3A | ≤200 | 6 | 22.921 | 160*190 |
GNRP1000 | 720 | 900 | 800 | 1000 | 4008-TAG1A | ≤206 | 8 | 30.561 | 160*190 |
GNRP1125 | 818 | 1022 | 900 | 1125 | 4008-TAG2A | ≤208 | 8 | 30.561 | 160*190 |
GNRP1375 | 1000 | 1250 | 1100 | 1375 | 4012-46TWG2A | ≤212 | 12 | 45.482 | 160*190 |
Genset Features:
1. Genuine UK industrial diesel engine
2. Radiator 40°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9.Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards
15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Engine Features:
1. Genuine UK Perkins industrial diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
Alternator Features:
1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts
7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528
9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel
Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.
Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown
Soundproof/Silent Box:
1. Excellent ventilation
2. Oil tank mounted on base frame for 12 Hours working
3. Highly Corrosion Resistant construction
4. Excellent Access for Maintenance
5. Security and Safety
6. 1m<80DBA / 7m<70DBA
Optional:
1. Trailer type
2. Soundproof / water proof
3. ATS (automatic transfer switch)
4. Parallel system
5. Remote system
PMC System:
1. Standard 23 pitch windings avoid excessive neutral current
2. Permanent magnet generator system provides constant excitation under all condition
3. Optional accessories available for easy paralleling with mains or other generators
4. AVR auto voltage regulation, auto exciter, auto adjustment
- Q: What is the difference between a step motor and an ordinary motor
- The step motor is in the position control general motors are usually the speed control and the control of the two is different. Position control means that you can set the number of times you want your motor to rotate (a circle of 360 degrees), and speed control means how much your motor is going to turn/minute. This can be seen in the low speed of the step motor, which is the high speed of the motor.
- Q: What is a hydraulic motor
- The high speed motor gear motor has the advantages of small size, light weight, simple structure, good technology, not sensitive to the pollution of the oil, the shock resistance and small inertia. The disadvantages include higher torque ripple, low efficiency, low starting torque (60% to rated torque) and low speed stability.
- Q: What is the difference between a three-phase asynchronous motor and a regular motor?
- Torque motor: a special motor with soft mechanical properties and wide speed range. This motor is not powered by constant power output but by constant torque output. Torque motor includes: dc torque motor, ac torque motor, and brushless dc torque motor. Difference: torque motor is to in the case of lower speed without changing the output torque, motor speed when lowering power supply voltage drops, but the output torque constant, current is the same. Ordinary motors cannot be slowed down by reducing pressure, which will cause the output torque to decrease and the current increase, which will burn the motor. Change frequency converter control: to confirm the torque motor that is controlled is ac asynchronous motor or synchronous motor because the frequency converter is used on ac. It is also important to confirm that the maximum current of the frequency converter is greater than or equal to the current of the torque motor, since the torque motor is able to work in a blocked state.
- Q: What is the difference between a general motor and a high-speed motor?
- The rotational inertia of high speed motor is generally small, so the long type of motor is more.
- Q: A 2.2 KW motor will require a lot of electricity a day
- First you have to determine whether the motor is working under the rated load at 2.2 KW, which is 24 hours a day Electricity is 2.2 * 24 = 52.8 degrees. Don't need to be multiplied by three.
- Q: The motor does not turn except sound
- Is the connection ok? The sound of the urn is the coils of the coils. What's the electric motor.:If it's a single phase of the motor that might be a fault of the current or the initiating device, the third phase is the power supply,.
- Q: Does the motor swing around?
- First can tear down load belt try, if still swinging, that is the motor is out of the problem to see not fixed, or the inside of the bearing looseness, if there is something wrong with the bearing should be supposed to send sound or with fixed load. If you put a belt on it, it's probably a belt that's not tuned and you can figure out how to do it.
- Q: Why does the direct start-up of high power motors affect the voltage of the grid
- The ac motor starts with a current of 5 to 7 times the rated current. The effect of the high power motor directly on the voltage of the grid; The main consideration is that a large start current will reduce the voltage of the grid and cause a ripple effect. Normally, the power grid transformer capacity is over 180kVA, and the power of the motor is below 7kW. At present 4-100kw motor multi-purpose delta voltage drop starting..
- Q: The difference between servo motor and general motor?
- The insulation level, which is usually F or higher, strengthens the insulation strength of the ground and turns, especially considering the ability of insulation to withstand shock voltage. 2) to the problem of vibration and noise of the motor, the motor should be fully considered component and overall rigidity, trying to improve its natural frequency, in order to avoid and every force wave resonance phenomenon. 3) cooling mode: the general adoption of forced ventilation cooling, the main motor cooling fan is driven by an independent motor. To prevent shaft current measures, the bearing insulation measures should be applied to the capacity exceeding 160KW motors. Mainly produces magnetic circuit asymmetry, also can produce shaft current, while the rest of the high frequency component generated by the current role in combination, shaft current will increase greatly, which can lead to bearing damage, so often insulation measures. For constant power frequency converter motor, the special lubricating grease should be used to compensate the temperature of the bearings when the speed is over 3000 / min.
- Q: What is the difference between servo motor and general motors?
- Servo motors belong to precision motors, and the smaller power, have their own Angle feedback signal, each round will produce more than 10000 Angle signal, extremely accurate, generally used in precision machining, special equipment, use to have a high precision requirement, general motors just a equipment of electrical energy into kinetic energy, there is no other auxiliary functions
Send your message to us
Water Cooled Perkins Genset Diesel Generator 40kva With Heavy Duty Engine
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords