Spectacle wear plate for IHI concrete pump
1.Specifications:
Size | DN205, DN220 |
Material | tungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany |
Lifetime | 30,000-80,000cbm |
Carbide HRA | > 86 |
Electrode HRC | > 63 |
Type | hardfaced, tungsten carbide and 7 shape tungsten carbide |
Application | mud pump, shotcrete,trailer and truck mounted concrete pump |
Manufacturer with competitive price |
Leading manufacturer for all kinds of brand concrete pump wear plate, technical date as below
Technology | Technical Standard | Service Life | Hardness |
Atmosphere sintering process | SY5064-85 | 5 times more than similar traditional product | HRC>70 |
Tensile Strength | Fracture Toughness values | Yield Strength | |
>1000Mpa | 10 Mpa1/2 | >1000Mpa | |
Substrate/Matrix Material | Bending Strength | High Temprature Resistance | Surface Roughness |
45#,40Cr, 1Cr13 steel | 1100-1300 Mpa | 700-800 centigrade degree | Ra<0.1< td=""> |
Bond Strength | Corrosion Resistance | Compactness | |
>110Mpa | >95% | Gas Hole Ratio<0.01%< td=""> |
2.Packing:
1. Outside package: standard export wooden case
2. Inside package: bubble bag
3. Why choose us?
1. Manufacturers with 8 year's experiences.
2. High quality, best price, prompt delivery.
3. Standard quality control system
4. Small orders are accepted.
Experience: 1. over 8 years concrete pump wear part’s experiences.
2. 4 years gold supplier on alibaba.
3. 2 years OEM.
Quality: 1. ISO9001 certification.
2. Strictly quality control with every process.
3 . Material: electrode imported from Germany. Q235B steel body.
4. High performance.
5. Advanced manufacturing equipment and leading technical.
Type: Different types with different lifetime.
OEM, ODM is acceptable.
Service: Delivery: 7-10 days after receiving the money.
MOQ: 1 set.
Prompt attention must be paid to any requirement and inquiry.
Price: Different price with different types,
we are faithfully that our price can help you beat your competitor with the same type product.
We are leading manufacturer for concrete pump wear plate, S valve and other wear parts in the hopper for more than 8 years, with high quality and competitive price, all kinds of brand you can find from us, such as PM, Schwing, Sany, Zoomlion, Cifa, Sermac, IHI, Niigata, Mitsubishi, Kyokuto, KCP, Jacon, Elba...etc.
OEM service is available, products can be produced as buyer's drawing or samples.
At the same time, we also sell following parts with good quality and competitve price:
1. Concrete pump clamp in casted and forged
2. Concrete pump rubber hose
3. Delivery pipe and elbow
4. Piston
5. Sponge ball
6. Delivery cylinder
7. Plunger cylinder
Any questions, I am Hilary here. feel free to contact me.
- Q: The function of centrifugal pump
- 4, bearings are set on the pump shaft supporting the pump shaft components, there are two kinds of rolling bearings and sliding bearings. Rolling bearings use butter as a lubricant, refueling should be appropriate, generally 2/3 ~ 3/4 of the volume is too much, will heat, too little, there is noise and fever! The plain bearings are made of transparent oil as a lubricant and fill up to the oil level. Too much oil will leak out along the pump shaft and float *, too little, the bearings will overheat and burn out, causing accidents! In the pump running process, bearing temperature is highest in 85 degrees, generally run at about 60 degrees, if higher, will find the reason (whether there is impurities, whether the oil is black, whether water) and timely processing!
- Q: Is the diaphragm pump and the drain pump one?
- Generally composed of actuators and valves.Pneumatic diaphragm pump, which has four kinds of materials: plastic, aluminum alloy, cast iron, stainless steel. The electric diaphragm pump has four kinds of materials: plastic, aluminum alloy, cast iron and stainless steel. Diaphragm pump diaphragm according to different liquid media, respectively, NBR, chloroprene rubber, fluorine rubber, PTFE, poly 46 ethylene to meet the needs. Placed in a variety of special occasions, for pumping various media.
- Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
- The diaphragm pump and centrifugal pump refer to the structure of the pump, and the vacuum pump means the use of the pump. There is no comparability between them.Centrifugal is the sign of inertia of an object. As the umbrella turns, water droplets move out of the outer edge of the umbrella and are thrown out. This is what is called centrifugal. Centrifugal pump is designed according to this principle. The high speed rotating impeller blade drives the medium to rotate and is thrown out so as to achieve the purpose of conveying.
- Q: I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
- The pressure loss is borne by the valve. Constant pressure pumps generally do not export direct load, unless you need this load response is very fast, then the maximum displacement of the pump work, so as to ensure the rapid response of the load.
- Q: How to install, operate and maintain the pipeline booster pump?
- Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
- Q: What is the function of the heating pump system for the water pump design?
- Will cause some of the internal friction gap disappeared, the coupling center damage. In this case, starting the pump inevitably results in vibration, friction, etc.
- Q: How many pumps does the 80cm tank use?
- Mainly look at the flow of the pump, all pumps have flow signs, such as 15L/HThe above is I at random, meaning that 15 litres per hour. You should calculate the volume of your cylinder, that is, the length of the tank, the width and the height of the water surface, the unit is cm. The result is 1000, which is the volume of your fish tank
- Q: What is a feed pump?
- Feeding the role of the pump is to make the injection pump inlet pressure, increase the injection pump inlet pipe flow rate, in order to ensure high pressure water injection pump has sufficient supply.
- Q: Which nuclear submarines use the shaftless pump technology?
- Shaftless pumping technology and Simulation of shark skin technology are all the next generation of submarine propulsion technology. At present, there is no submarine in the world.
- Q: What is the difference between centrifugal pump and self suction pump? Which is better?
- If the centrifugal pump in full before the start of the shell of the gas, then start after the center of the impeller was thrown in the gas can not be large enough to form the vacuum, so that liquid in the bath can not be sucked, so the centrifugal pump to start before using foreign liquid in the pump housing space filling
Send your message to us
spectacle wear plate for IHI concrete pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 1000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords