1.Structure of  Single Stage Double Suction Centrifugal Water Pump Description

 

Split Casing Double Suction Centrifugal Water Pump is a single-stage centrifugal pump, horizontal in the open, for the transport of water and physical and chemical properties similar to water in liquid, the liquid temperature should not exceed 80 °C, suitable for factories, mines, power plants, city drainage, drainage irrigation and water conservancy

 

2.Main Features of the Single Stage Double Suction Centrifugal Water Pump

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3. Single Stage Double Suction Centrifugal Water Pump images

Single Stage Double Suction Centrifugal Water Pump

4. Single Stage Double Suction Centrifugal Water PumpSpecification

 

Item

Agricultural irrigation water pump

Electric irrigation water pump

SH series agricultural irrigation water pump

Model

SH

Material

Cast iron and customized

Color

Blue and adjustable

Mode

Horizontal

Impeller

Double suction impeller

Drive

Belt or coupling

Seal

Soft packing seal or mechanical seal

Speed

2950r/m, 1470r/min, 970r/min

Theory

Centrifugal pump

Structure

Single stage pup

Usage

Pure water or raw water

Power

Electric

Standard or Nonstandard

Standard

Application

Plant, mine, power station, urban water supply, irrigation

Outlet diameter

100-900mm

Capacity

111-12500m³/h

Head

8.6-140m

Power

22-1250kw

Warranty

1year

Certificate

ISO9001

OEM

Acceptable

Feature

High flow rate, high efficiency, easy maintenance

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q: How can the submersible pump level meter be connected?
Install liquid level controller, two position liquid level sensor, controller to buy manual, wiring according to wiring diagram.
Q: Why should the pump be closed when the centrifugal pump is started?
On the other hand, the water on the pipe of the inlet pipe of the pump is stationary before the pump is opened, such as the sudden acceleration, and the water behind it can not keep up, which will cause the pressure of the inlet to drop suddenly and vaporize the water, and the centrifugal pump will be evacuated. (because of the centrifugal pump is rotating centrifugal force generated by the pump, leaf water and steam driven (gas) quality is very light, according to F= Ma, the centrifugal force is small, the pump can not be water sent).
Q: There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
Indoor fire hydrant pump in addition to remote direct Kai, there are modules to start function, that is, on the cabinet to add control module, bus linkage pump, but also fire hydrant button, direct pumping function, a total of three functions.Outdoor fire hydrant pump in addition to remote direct Kai, but also an electric contact pressure meter detection system, water pressure from the pump and high pressure pump stop function.
Q: Why can't the inlet of centrifugal pump be negative pressure?
Therefore, the centrifugal pump inlet pressure can be negative, and negative number, should be used to pump cavitation margin and liquid saturated steam pressure parameters to specific calculation. Sometimes, the liquid saturated steam conveying pressure is very high, such as the 9 m water column, then the minimum pressure of the pump inlet should be equal to 4+9=13 meters, the atmospheric pressure is higher than 3 meters, not only for negative pressure, even higher than the atmospheric pressure to work properly.
Q: How is the pump level of submersible sewage pump determined?
Generally as:The bottom elevation of sump sump plus 300 is the water level of pump stopThe top 300 of the sump top elevation is the pump water level
Q: How can I buy a pump?
3 、 mechanical requirements of high reliability, low noise, vibration.4, the correct calculation of pump procurement costs, the pump manufacturer to inspect, requiring good quality equipment, good after-sales service, spare parts can be timely supply.The micro pump and the motive of the mechanical energy or other external energy transmitted to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids.The technical parameters of pump performance include flow, suction, lift, shaft power, water power, efficiency and so on.
Q: What is the nominal pressure of the hydraulic pump and hydraulic motor?
Related concepts of hydraulic motorsFlow theoretical volume refers to the volume of oil inhaled in unit time without leakage.
Q: Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines? Why?
Unreasonable, easy to produce throttling loss, pressure loss, pressure reduction, easy to cause cavitation
Q: What is the series of pumps? What is the difference between a unipolar and a multilevel? What is the meaning of each "first class"?
A single-stage pump is a pump with only one impeller. 2, a multistage pump is a pump with two or more impellers. The multistage pump can increase the pressure and lift the head higher. Level 1 means a booster impeller.
Q: How long does the fine stone pump need maintenance? What should I pay attention to?
Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe