• Spectacle wear plate  for Kyokuto concrete pump System 1
Spectacle wear plate  for Kyokuto concrete pump

Spectacle wear plate for Kyokuto concrete pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
1000sets per month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Spectacle wear plate for Kyokuto concrete pump

1.Specifications:

SizeDN205,DN225
Materialtungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany
Lifetime30,000-80,000cbm
Carbide HRA> 86
Electrode HRC> 63
Typehardfaced, tungsten carbide and 7 shape tungsten carbide
Applicationmud pump, shotcrete,trailer and truck mounted concrete pump
Manufacturer with competitive price


Leading manufacturer for all kinds of brand concrete pump wear plate, technical date as below


TechnologyTechnical StandardService LifeHardness
Atmosphere sintering processSY5064-855 times more than similar traditional productHRC>70
Tensile StrengthFracture Toughness valuesYield Strength
>1000Mpa10 Mpa1/2>1000Mpa
Substrate/Matrix MaterialBending StrengthHigh Temprature ResistanceSurface Roughness
45#,40Cr, 1Cr13 steel1100-1300 Mpa700-800 centigrade degreeRa<0.1
Bond StrengthCorrosion ResistanceCompactness
>110Mpa>95%Gas Hole Ratio<0.01%




2.Packing:

1. Outside package: standard export wooden case

2. Inside package: bubble bag


3. Why choose us?

1. Manufacturers with 8 year's experiences.


2. High quality, best price, prompt delivery.


3. Standard quality control system


4. Small orders are accepted.



Experience: 1. over 8 years concrete pump wear part’s experiences.

                     2. 4 years gold supplier on alibaba.

                     3. 2 years OEM.

Quality: 1. ISO9001 certification.

               2. Strictly quality control with every process.

               3 . Material: electrode imported from Germany. Q235B steel body.

               4. High performance.

               5. Advanced manufacturing equipment and leading technical.

Type: Different types with different lifetime.

          OEM, ODM is acceptable.

Service: Delivery: 7-10 days after receiving the money.

               MOQ: 1 set.

               Prompt attention must be paid to any requirement and inquiry.

Price: Different price with different types,

we are faithfully that our price can help you beat your competitor with the same type product.


We are leading manufacturer for concrete pump wear plate, S valve and other wear parts in the hopper for more than 8 years, with high quality and competitive price, all kinds of brand you can find from us, such as PM, Schwing, Sany, Zoomlion, Cifa, Sermac, IHI, Niigata, Mitsubishi, Kyokuto, KCP, Jacon, Elba...etc.  

OEM service is available, products can be produced as buyer's drawing or samples.

At the same time, we also sell following parts with good quality and competitve price:


1. Concrete pump clamp in casted and forged

2. Concrete pump rubber hose

3. Delivery pipe and elbow

4. Piston

5. Sponge ball

6. Delivery cylinder

7. Plunger cylinder


Any questions, I am Hilary here. feel free to contact me.


Q: What are the uses and precautions of magnetic pumps?
5, after the motor starts, slowly open the drain valve, until the pump into the normal working state, and then discharge valve to the desired opening;6, before the pump stops working, should first close the exhaust valve, and then turn off the suction valve.
Q: What is cavitation, centrifugal pump cavitation phenomenon how to solve?
Centrifugal pump cavitation phenomenon how to solve?:Measures to improve cavitation resistance of centrifugal pumps(1) improve the design of the suction port of the centrifugal pump to the impeller. Increase flow area; the radius of curvature increases the impeller cover inlet section, reduce the flow accelerated sharply with pressure; reduce the thickness of the blade, and the blade inlet rounded, close to the streamline, can also reduce the acceleration and pressure flow around the blade head portion of the impeller and the blade inlet part; improve surface finish in order to reduce the resistance loss; the blade inlet edge extends to the impeller inlet, the liquid flow in advance to accept work pressure, improve.
Q: What is double hydraulic pump?
The 2 pumps are all coaxial connected together, driven by a motor, the general gear pump, piston pump
Q: What is the pump delivery? What's the difference between years and years?
Secondly, the landlord asked the question, although I did not go to the insurance company to practice the operation, but to my four years of learning, as well as internship experience, or can help you analyze, and I hope to help you.Pay is a one-time payment of premium -- all wholesale D sea n
Q: How many square cables does the submersible pump for 7.5KW need?
7.5KW's submersible pump requires 2.5 square aluminum cables.Calculate the current value of submersible pump first:
Q: What is the difference between the ground pump and the pump in the commercial concrete?
Day pump: the pump and pipe will be placed in a position on the site, the pipe in the air like the crane arm
Q: Why can't the centrifugal pump pump the vacuum?
Characteristic equation of centrifugal pumpStudy the effect of fluid on centrifugal pump to obtain energy.The experimental condition of u is that the ideal fluid of unit weight bends the flow between blades at infinity.U investigated the mechanical energy balance of the fluid between the adjacent two inlet and outlet sections, that is, the relationship between theoretical pressure head and theoretical flow.
Q: What does "dual purpose" of water pump mean? Please expert advice
2, the pump must pay attention to maintenance after use, for example, when the pump is used up, the water pump should be put clean, it is best to remove the water pipe, and then rinse with water.5, the water pump on the tape should be removed, and then rinse with water after drying in the light place, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.6, to carefully check whether there are cracks in the impeller, the impeller fixed to the bearing on whether there is loose, cracks and loose if the phenomenon to be timely maintenance, if the water pump impeller should also be above the earth clean.
Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system:
Q: Attention should be paid to the use of pumps?
1, pump shaft packing completely worn, it is necessary to add in time, if you continue to use the water pump will leak. The direct effect of this is the increased energy consumption of the motor, which will damage the impeller. 2, the use of pumps in the course of a strong vibration, then must stop to check the reasons, or the same will cause damage to the water pump. 3 gear pump valve Water Leakage, some will use the soil into the water pump inlet tube, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started working, these dry soil will enter the pump, which will damage the pump impeller and bearings, which shorten the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that it is necessary to replace the new. 4 after the use of pumps must pay attention to maintenance, for example, when the pump is exhausted, we should put the water pump who put clean, it is best to remove the water pipe, and then rinse with water. 5 water pump on the tape should also be written down, and then always flush, and then light out to dry, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords