Spectacle wear plate for Jacon concrete pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 1000sets per month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Spectacle wear plate for Jacon concrete pump
1.Specifications:
Size | 6'', 8'' |
Material | tungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany |
Lifetime | 30,000-80,000cbm |
Carbide HRA | > 86 |
Electrode HRC | > 63 |
Type | hardfaced, tungsten carbide and 7 shape tungsten carbide |
Application | mud pump, shotcrete,trailer and truck mounted concrete pump |
Manufacturer with competitive price |
Leading manufacturer for all kinds of brand concrete pump wear plate, technical date as below
Technology | Technical Standard | Service Life | Hardness |
Atmosphere sintering process | SY5064-85 | 5 times more than similar traditional product | HRC>70 |
Tensile Strength | Fracture Toughness values | Yield Strength | |
>1000Mpa | 10 Mpa1/2 | >1000Mpa | |
Substrate/Matrix Material | Bending Strength | High Temprature Resistance | Surface Roughness |
45#,40Cr, 1Cr13 steel | 1100-1300 Mpa | 700-800 centigrade degree | Ra<0.1 |
Bond Strength | Corrosion Resistance | Compactness | |
>110Mpa | >95% | Gas Hole Ratio<0.01% |
2.Packing:
1. Outside package: standard export wooden case
2. Inside package: bubble bag
3. Why choose us?
1. Manufacturers with 8 year's experiences.
2. High quality, best price, prompt delivery.
3. Standard quality control system
4. Small orders are accepted.
Experience: 1. over 8 years concrete pump wear part’s experiences.
2. 4 years gold supplier on alibaba.
3. 2 years OEM.
Quality: 1. ISO9001 certification.
2. Strictly quality control with every process.
3 . Material: electrode imported from Germany. Q235B steel body.
4. High performance.
5. Advanced manufacturing equipment and leading technical.
Type: Different types with different lifetime.
OEM, ODM is acceptable.
Service: Delivery: 7-10 days after receiving the money.
MOQ: 1 set.
Prompt attention must be paid to any requirement and inquiry.
Price: Different price with different types,
we are faithfully that our price can help you beat your competitor with the same type product.
We are leading manufacturer for concrete pump wear plate, S valve and other wear parts in the hopper for more than 8 years, with high quality and competitive price, all kinds of brand you can find from us, such as PM, Schwing, Sany, Zoomlion, Cifa, Sermac, IHI, Niigata, Mitsubishi, Kyokuto, KCP, Jacon, Elba...etc.
OEM service is available, products can be produced as buyer's drawing or samples.
At the same time, we also sell following parts with good quality and competitve price:
1. Concrete pump clamp in casted and forged
2. Concrete pump rubber hose
3. Delivery pipe and elbow
4. Piston
5. Sponge ball
6. Delivery cylinder
7. Plunger cylinder
Any questions, I am Hilary here. feel free to contact me.
- Q: The water tank of the fish tank does not air out and only has the water outlet
- The air inlet pipe is connected with the oxygen burst, the entrance also pulled out, we can see that it is the design of a miter, the oblique incision back to the direction of the water flow speed, this outflow, negative pressure is formed in the oblique incision, the air can be sucked in. As shown.
- Q: How many millimeters is the diameter of the water outlet of the four inch pump?
- If it is a centrifugal pump, the nominal diameter of the outlet is less than 4 inches, there is a conical short tube to enlarge the standard 4 inch outlet flange, from here, is the standard 4 inch flange connection.
- Q: What is double hydraulic pump?
- [double hydraulic pump] the same drive shaft drives the rotation of two pumps, which are connected together and driven by an electric motor. The suction port of the pump is common, and the oil pressure port is separated from each other. Pump output of two shares of flow can be used alone, can also be used in parallel. This pump, a pump can play the function of two pumps. For example, there are two pumps on the loader, a pump acting as the work, a pump acting as the steering, and the double linked pump can replace the functions of the two pumps. It works by coupling the two pumps at the same time.
- Q: How to install, operate and maintain the pipeline booster pump?
- Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
- Q: What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
- The working principle of submersible pumpBefore the pump is opened, the suction pipe and pump must be filled with liquid. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet, the outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuously from the outflow discharge tube.
- Q: Rules for operation of centrifugal pumps
- Operating rules:1, before starting to check whether the water pump foot loose, coupling shield, and motor fan blade cover is intact, in order to ensure the safety of equipment and personal safety.2. Check whether the inlet valve is open and open as fully as possible. Is the outlet valve closed, open the bleeder valve, exhaust until there is no air, and close the bleeder valve. At the end of the valve to the pipeline in the pump cavity filled with water.
- Q: What is the liquid pump? What are their categories? What are their strengths and weaknesses?
- The pump is constructed by connecting large diameter gas piston with small diameter hydraulic piston. The two piston area ratio produces a pressure ratio, and the maximum output pressure can be calculated by the pressure ratio. High pressure ratio produces high outlet pressure. You can set the outlet pressure through a simple gas pressure reducing valve. Pressure ratio * gas drive pressure = output pressure.
- Q: How can I buy a pump?
- Selection principle of pump:1, so that the selected pump type and performance parameters meet the unit flow, lift, pressure, temperature and other requirements, the most important thing is to determine the voltage, the maximum lift, and when the head high reached much traffic.
- Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
- What is straight pump and non direct pump? Direct coupled pump shaft and the motor shaft is directly coupled with the coupling and non direct coupled pump: pump shaft and motor shaft through the belt pulley, V-belt connection or other forms of transmission. What is the difference in the structure: the direct coupled pump has the advantages of compact structure, simple installation, but the relatively small power; non direct coupled pump: pump and motor is independent, the two transfer torque through the belt, the structure is relatively large, complex installation, general power is relatively large.
- Q: Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
- Centrifugal pump, and is a very common method of centrifugal pump, flow with the head (or pressure) increases, off a small valve resistance increases, the pump head should be increased, then the flow decreased, whereas open valve flow increase
Send your message to us
Spectacle wear plate for Jacon concrete pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 1000sets per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords