1.Specifications:
Size | DN150, DN180,DN200,DN230 |
Material | tungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany |
Lifetime | 30,000-80,000cbm |
Carbide HRA | > 86 |
Electrode HRC | > 63 |
Type | hardfaced, tungsten carbide and 7 shape tungsten carbide |
Application | mud pump, shotcrete,trailer and truck mounted concrete pump |
Manufacturer with competitive price |
Leading manufacturer for all kinds of brand concrete pump wear plate, technical date as below
Technology | Technical Standard | Service Life | Hardness |
Atmosphere sintering process | SY5064-85 | 5 times more than similar traditional product | HRC>70 |
Tensile Strength | Fracture Toughness values | Yield Strength | |
>1000Mpa | 10 Mpa1/2 | >1000Mpa | |
Substrate/Matrix Material | Bending Strength | High Temprature Resistance | Surface Roughness |
45#,40Cr, 1Cr13 steel | 1100-1300 Mpa | 700-800 centigrade degree | Ra<0.1< td=""> |
Bond Strength | Corrosion Resistance | Compactness | |
>110Mpa | >95% | Gas Hole Ratio<0.01%< td=""> |
2.Packing:
1. Outside package: standard export wooden case
2. Inside package: bubble bag
3. Why choose us?
1. Manufacturers with 8 year's experiences.
2. High quality, best price, prompt delivery.
3. Standard quality control system
4. Small orders are accepted.
Experience: 1. over 8 years concrete pump wear part’s experiences.
2. 4 years gold supplier on alibaba.
3. 2 years OEM.
Quality: 1. ISO9001 certification.
2. Strictly quality control with every process.
3 . Material: electrode imported from Germany. Q235B steel body.
4. High performance.
5. Advanced manufacturing equipment and leading technical.
Type: Different types with different lifetime.
OEM, ODM is acceptable.
Service: Delivery: 7-10 days after receiving the money.
MOQ: 1 set.
Prompt attention must be paid to any requirement and inquiry.
Price: Different price with different types,
we are faithfully that our price can help you beat your competitor with the same type product.
We are leading manufacturer for concrete pump wear plate, S valve and other wear parts in the hopper for more than 8 years, with high quality and competitive price, all kinds of brand you can find from us, such as PM, Schwing, Sany, Zoomlion, Cifa, Sermac, IHI, Niigata, Mitsubishi, Kyokuto, KCP, Jacon, Elba...etc.
OEM service is available, products can be produced as buyer's drawing or samples.
At the same time, we also sell following parts with good quality and competitve price:
1. Concrete pump clamp in casted and forged
2. Concrete pump rubber hose
3. Delivery pipe and elbow
4. Piston
5. Sponge ball
6. Delivery cylinder
7. Plunger cylinder
Any questions, I am Hilary here. feel free to contact me.
- Q:There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
- You said the three line refers to the control room, the control cabinet, the main pump directly start the straight line of water pump. Each pump should be equipped with single straight line Kai, reported that the cabinet Jinglian dynamic multi line linkage control board has three buttons corresponding to a remote spray pump, fire hydrant pump, pump start outdoor fire hydrant. This requires three straight lines, from the cabinet to the three pump control cabinet, which is the 9 line you call. The water pump control cabinet is provided with a terminal for supplying a remote pump. By looking at the wiring diagram of the water pump control box, you can find the technical personnel of the control cabinet manufacturer if you can't find them.
- Q:What is the series of pumps? What is the difference between a unipolar and a multilevel? What is the meaning of each "first class"?
- You're talking about a centrifugal pump. His series says the number of slices of the impeller (excluding the wheel, that is, the wheel)
- Q:Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
- The direct connected pump impeller is directly mounted on the motor shaft, and the non direct connected pump and motor are two shafts, and the two shafts transmit torque through the coupling
- Q:What is the difference between the ground pump and the pump in the commercial concrete?
- Move back and forth; pour concrete into a certain area. After the filling is finished, the whole pump truck can be moved to another position quickly
- Q:What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
- SK vacuum pump is a single-stage water ring vacuum pump, vacuum pump and motor separation, coupled with couplings, vacuum relatively low.
- Q:How is the pump level of submersible sewage pump determined?
- Pump water level must be higher than the water pump top, so that the motor running in the lower water temperature cooling environment, otherwise long-term operation will burn the machine
- Q:What is the minimum continuous flow of a pump?
- Quality solutionsMinimum flow of pump, minimum continuous flow of pumpIn order to ensure the proper use of the pump and the normal operation of the pump manufacturer will indicate the minimum pump in the sample of the continuous operation flow, the correct selection or use to warn or instruct users. According to the provisions of the API standard, the minimum continuous flow into the minimum continuous stable flow and continuous flow. Most small thermal limit(1) the minimum continuous stable flow.API standard specifies the minimum continuous stable flow refers to the vibration limit does not exceed the standard set by the pump can work normally. The minimum flow pump at small flow rate, there will be noise and vibration increase, API of this provision is to ensure that the service life of the pump, avoid due to improper operation of the pump caused by the adverse effects.
- Q:What are the starting and stopping procedures for centrifugal pumps?
- Operation method and operation procedure of self-priming centrifugal pumpClick number: 440 release time: 2011-7-24Centrifugal pump method, centrifugal pump operation steps, centrifugal pump use steps
- Q:Hydraulic pump displacement refers to the pump shaft what?
- You can see the sign of your hydraulic pump. There will be a displacement **ml/r in the sign of the hydraulic pump (r stands for every turn, ML is milliliter)
- Q:What are the general water pump failure, how to repair?
- Troubleshooting of water pumpFirst, the water pump does not cause water analysisThere is air in the inlet pipe and pump body(1) before the water pump is started, the water is not filled enough. Sometimes it seems that the water has been discharged from the vent hole, but the pump shaft is not rotated. The air is completely discharged, resulting in a small amount of air remaining in the inlet pipe or pump body.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Spectacle wear plate for Schwing concrete pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 1000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords