Single Stage Split Case Farm Irrigation Water Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Specifications of Single Stage Split Case Farm Irrigation Water Pump • Horizontal single-stage double-suction water pump
• High efficiency
• Easy maintenance
• OEM/ODM
• Good quality and service
2.Main features of Single Stage Split Case Farm Irrigation Water Pump
High quality centrifugal pump apply to transporting pure water or liquids with physical and chemical properties to water..
Apply to power plant circulation.
Apply to water treatment.
Apply to agricultural irrigation.
Apply to flood control, hydraulic projects.
3.Specification of Single Stage Split Case Farm Irrigation Water Pump
Item | high volume farm irrigation pump |
low pressure farm irrigation pump | SH series high volume farm irrigation pumps |
Model | SH |
Material | Cast iron and customized |
Color | Blue and adjustable |
Mode | Horizontal |
Impeller | Double suction impeller |
Drive | Belt or coupling |
Seal | Soft packing seal or mechanical seal |
Speed | 2950r/m, 1470r/min, 970r/min |
Theory | Centrifugal pump |
Structure | Single stage pup |
Usage | Pure water or raw water |
Power | Electric |
Standard or Nonstandard | Standard |
Application | Plant, mine, power station, urban water supply, irrigation |
Outlet diameter | 100-900mm |
Capacity | 111-12500m³/h |
Head | 8.6-140m |
Power | 22-1250kw |
Warranty | 1year |
Certificate | ISO9001 |
OEM | Acceptable |
Feature | High flow rate, high efficiency, easy maintenance |
4.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we will
recommend relevant product for reference.
- Q: Know flow and lift how to calculate the pump power?
- The pump power (kw) ={9.61* flow (cubic meters per second) * head (m)}/.Where ETA is device efficiency, including mechanical, electrical loss and other factors, generally between 55%~80%. The smaller the pump, the lower the efficiency.
- Q: What is the Rhodes pump?
- Work principle editorRoots-type pump is a vacuum pump without internal compression, usually compression ratio is very low, so high and medium vacuum pumps need pre pump.A vacuum pump for pumping air by pumping a gas by the simultaneous rotation of a pair of lobed rotors in a pump cavity and a reverse rotation.Roots vacuum pump is a mechanical vacuum pump with a pair of synchronous and high-speed rotating sole shaped rotors. The pump can not be drawn out separately. The front stage needs to be equipped with an oil seal and a water ring, etc. it can be discharged directly into the atmosphere.
- Q: What are the ways of hydraulic pumps?
- Check valves, such as single piston pumps, three piston pumps, etc.;The port of the valve arrangement, such as the radial piston pump.
- Q: What are the functions of a disposable infusion pump?
- When the transfusion is too slow, the dosage may not be enough, or the infusion time is prolonged unnecessarily, the treatment is affected, and unnecessary burden is added to the patient and the nursing work. In routine clinical infusion, the infusion of hanging bottle is generally used, and the speed of infusion is controlled by the use of a manual clamp. The speed of infusion is not easy to be controlled accurately, and the workload is great.Treatment of cancer patients with chemotherapy and critically ill patients need to make drug infusion rates constant, by adjusting the input speed and duration of chemotherapy drugs is continuously injected into the uniform, not only to achieve the best effect of chemotherapy, and to minimize the side effects of chemotherapy drugs.People suffering from diabetes need to inject a certain amount of insulin at a certain speed. The previous approach is basically a large dose of insulin injection, which not only caused a huge waste, and the effect of time is relatively short, so for a conveying device of flow and velocity control, to carry a small amount of drugs and precisely control the conveying speed and flow.Some special drug delivery to the elderly, children and physical weak, such as drugs, antihypertensive drugs, sodium nitroprusside (three TPN codehydrogenase) when the infusion rate and dosage should seriously control accurately, otherwise it will have serious consequences.
- Q: What are the reasons for sealing damage of centrifugal pumps?
- Three, water shortages caused by running dry grinding damage.This phenomenon is more common in mounted form inlet pressure, inlet air, air cavity pump, pump boot, high temperature operation of the mechanical seal friction at high speed, can not be cooled, check the mechanical seal, the spring tension is normal, the friction surface of charred black, rubber hard cracking.Treatment methods: exhaust the pipe and pump cavity air, replace the machine seal.Four, install too tight, observe the mechanical seal of dynamic and static ring plane, if there is serious burning phenomenon, flat black and deep traces, sealing rubber hardens, lose elasticity.This phenomenon is due to tight installation.Treatment methods: adjust the installation height, impeller installed, with a screwdriver to move the spring, the spring has a strong tension, release after the reset, there is 2-4mm moving distance can.
- Q: Water pump outlet valve sequence
- In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
- Q: How to install, operate and maintain the pipeline booster pump?
- When the pump leaks, check it immediately to prevent leakage. If it leaks with the motor connection, replace the mechanical seal. Check that the power is connected. Is the supply voltage consistent with the operating voltage of the pump?. If the above a and B are normal, please remove the pump, open the pump cover, remove the foreign body in the pump, and then pump the lid on, and then tighten it to normal.No water pump, pump installed in the tap water pipeline, such as tap water level in the pump impeller on the plane (horizontal installation) or center line (vertical) below, you should turn off the power supply, to tap water level rise more than the impeller plane or the center line, connected to the power supply, to avoid mechanical damage (automatic no need to turn off the electric type). When the pump used in pumping wells, please check whether the water inlet pipe leak; pump cavity storage is not enough, should be filled with water, whether the suction process is too high, proper adjustment. Check whether the inlet and outlet diameter is too small or blocked. Automatic type after a period of time, there may be automatic failure phenomenon, mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging, can be re used.
- Q: How many kinds of pumps are available and the operating principles of various pumps?
- There are many kinds of pumps. There are different classifications according to different standards. If classified according to the principle of work, can be broadly divided into the following four categories:1, vane pumps: centrifugal pumps, axial pumps, mixed flow pumps, vortex pumps, etc.;2, displacement pumps: piston pumps, piston pumps, diaphragm pumps and so on;3, power rotary pump: screw pump, gear pump, etc.;4 、 special function: jet pump, water hammer pump, magnetic drive pump, etc.;
- Q: Why should I pump the pump before starting the centrifugal pump?
- 1., if it is backward flow, it is not pumping;2., if the pump is installed underwater (such as submersible sewage pump), it is not pumping;3. pump is for installation in the form of suction. If no diversion irrigation pump, then the pump is full of air quality, air density is less than water, the pump will not be inside the gas out, the pump pressure will not be far less than the atmospheric pressure, the water will not be pressed into the pump to pump through irrigation formed inside the closed environment, the pump will start water out will cause local vacuum, entrance external water pressure into the pump is in inside and outside differential pressure, complete water movement. (vacuum water diversion is directly through the vacuum pump pumping the air in the pump, resulting in internal and external pressure difference, the external water pressure in the internal and external pressure is press into the inlet of the pump. The principle is the same as the pump. A standard atmosphere of =10m water column.)
- Q: Brief description of centrifugal pump on / off operation
- (3) check whether the turning rotor is easy and flexible, check the pump body is clang or friction sound.(4) the protective cover is installed, and the shield contact.(5) clean the pump frame and do a good job of sanitation.(6) open the inlet valve, make the liquid full of pump body, open the vent valve, clean the air and close it. If the hot oil pump, it is not allowed to open the air valve exhaust, to prevent hot oil channeling spontaneous combustion, if there is a dedicated vent pipes and tanks, you can vent the pipe line air and cold oil.(7) the hot oil pump should be preheated slowly before starting. Especially in winter, the pump body and the pipe should be preheated at the same time, so that the temperature difference between the pump body and the conveying medium is below 50 centigrade.(8) the oil must be sufficiently dehydrated before being introduced into the oil pump.
Send your message to us
Single Stage Split Case Farm Irrigation Water Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches