• Single Stage Split Case Farm Irrigation Water Pump System 1
  • Single Stage Split Case Farm Irrigation Water Pump System 2
  • Single Stage Split Case Farm Irrigation Water Pump System 3
Single Stage Split Case Farm Irrigation Water Pump

Single Stage Split Case Farm Irrigation Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Specifications of Single Stage Split Case Farm Irrigation Water Pump

Horizontal single-stage double-suction water pump

High efficiency

Easy maintenance

OEM/ODM

Good quality and service

2.Main features of Single Stage Split Case Farm Irrigation Water Pump

  • High quality centrifugal pump apply to transporting pure water or liquids with physical and chemical properties to water..

  • Apply to power plant circulation.

  • Apply to water treatment.

  • Apply to agricultural irrigation.

  • Apply to flood control, hydraulic projects. 

3.Specification of Single Stage Split Case Farm Irrigation Water Pump

 

 

Item

high volume farm irrigation pump

 low pressure farm irrigation pump

SH series high volume farm irrigation pumps

Model

SH

Material

Cast iron and customized

Color

Blue and adjustable

Mode

Horizontal

Impeller

Double suction impeller

Drive

Belt or coupling

Seal

Soft packing seal or mechanical seal

Speed

2950r/m, 1470r/min, 970r/min

Theory

Centrifugal pump

Structure

Single stage pup

Usage

Pure water or raw water

Power

Electric

Standard or Nonstandard

Standard

Application

Plant, mine, power station, urban water supply, irrigation

Outlet diameter

100-900mm

Capacity

111-12500m³/h

Head

8.6-140m

Power

22-1250kw

Warranty

1year

Certificate

ISO9001

OEM

Acceptable

Feature

High flow rate, high efficiency, easy maintenance

 

 4.FAQ

 What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

 Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

 What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we will

recommend relevant product for reference.

Q: Why should the pump be closed when the centrifugal pump is started?
On the other hand, the water on the pipe of the inlet pipe of the pump is stationary before the pump is opened, such as the sudden acceleration, and the water behind it can not keep up, which will cause the pressure of the inlet to drop suddenly and vaporize the water, and the centrifugal pump will be evacuated. (because of the centrifugal pump is rotating centrifugal force generated by the pump, leaf water and steam driven (gas) quality is very light, according to F= Ma, the centrifugal force is small, the pump can not be water sent).
Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve, or pumping up water will not leak?Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".....
Q: How many millimeters is the diameter of the water outlet of the four inch pump?
Here is a 4 inch inch, not rural, 1 inches =25.4 mm, 4 inches is approximately 100mm, with DN100 pipeline.
Q: The distance from the pump button to the ground
After confirming that the fire pump has started running, issue a command signal to the hydrant button to light the green answer light.
Q: Double floor sewage pump circuit diagram of a small problem
Question 3 when the water level is low, when the 1KA is connected, the pump will run depending on where your SS selector switch is located. Its left and right position, running pump and standby pump definition is different, left position is 1#, running 2# standby, right position is 2# running, 1# standby. Only inIn case the high level switch 2KA is connected, the standby pump may work at the same time.
Q: What does "efficiency" mean in a water pump catalog?
General pump efficiency is 60% ~ 85%. high efficiency of the pump, indicating the same work, the pump consumes the lowest energy, and vice versa
Q: If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
Centrifugal pumps are too big to measure.There is a reason why the centrifugal pump does not measure up:The pump inlet pipe blockage, leakage.The pump inlet pressure is too low.
Q: The working principle of magnetic pump
Structure characteristics1. permanent magnetPermanent magnet operating temperature range is made of rare earth permanent magnet wide (-45 - 400 DEG C), high coercivity, magnetic anisotropy direction is very good, also won't happen in the same demagnetization phenomenon when is close, is a good source of the magnetic field.2. isolation sleeveIn the metal isolation, isolation sets in a sinusoidal alternating magnetic field, in a cross section perpendicular to the direction of magnetic field lines induced eddy current and converted into heat. Eddy current expression is:. The Pe - K constant; eddy current; rated speed of N - T - pump; magnetic drive torque; F - the pressure inside the sleeve; D sleeve diameter; a material resistivity; and the tensile strength. When the pump design is completed, N, T is the given conditions, to reduce eddy current only from F, D, and so on. Non metallic materials with high resistivity and high strength production isolation, in reducing the eddy current effect is very obvious.
Q: Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
Calculate or refer to the water pump nameplate that the normal operating current, according to this data exchange switch.2) with 500V shaking table, measuring the cable, motor insulation is in line with the requirements
Q: How to maintain and repair the booster pump of pipeline pump?
Installation and use1. use rubber washer and bolt to connect the pump flange at both ends and the pipe flange. In order to use and maintenance convenience, in the pump inlet and outlet pipelines should be installed with a regulating valve.2. open the inlet control valve, so that water into the pump, in order to keep the cavity filled with liquid (otherwise it will damage the seal), close the outlet valve.3. turn on the power and make sure the correct turn.4. make sure the pump starts and runs after turning.5. adjust the opening of the outlet valve so that the pump runs near the design point, depending on the rated flow and lift of the pump. [for this reason, it is better to place a pressure gauge near the outlet flange). Note: this pump is strictly prohibited to run without water, so as not to damage the seal.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches