• Product list of China Lovol Engine type (lovol)106 System 1
Product list of China Lovol Engine type (lovol)106

Product list of China Lovol Engine type (lovol)106

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
5000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
Exhaust System
Exhaust Gas Flow:2054L/s
Exhaust Temperature:584
Max Back Pressure:10kPa 
Air Intake System
Max Intake Restriction:6.23kPa 
Burning Capacity:750L/s
Fuel System
100%(Prime Power) Load Consumption:206 g/Kw.h
75%(Prime Power) Load Consumption:205 g/Kw.h
50%(Prime Power) Load Consumption:206 g/Kw.h
Oil System
Total Oil Capacity:50L 
Oil Pressure at Rated RPM:345-483kPa
Cooling System
Total Coolant Capacity:116.5L 
Thermostat:82-93
Max Water Temperature:104℃
ALTERNATOR DATA
Manufacturer:Original STAMFORD ,Marathon,MECC,Kaijieli
Frequency and Speed:50Hz/1500rpm
Altitude:1000m
Connecting Type:3 Phase and 4 Wires, “Y” Type Connecting
Power Factor:0.8
Protection Grade:IP23
Exciter Type:Brushless, Self-Exciting, with AVR
Insulation Class, Temperature Rise:H/H
GENERATING SET DATA
Voltage Regulation, Stead State:±1%
Volts Warp(Sudden Reduce):+25%
Volts Warp(Sudden Increase):-20%
Frequency Regulation, Stead State:5% 
Frequency Warp(Sudden Reduce):+12%
Frequency Warp(Sudden Increase):-10%
Frequency Recovery Time:5S
Open Type Size:3700(mm)X1570(mm)X2080(mm)
Open Type Weight:4820kg
Control System:Original Uk deep sea auto controller 
Standards: ISO9001, ISO14001, European CE


Q: What will be the effect of ambient temperature on diesel generators
Fully automatic diesel generator sets are more expensive than conventional diesel engines with the same brand, configuration and power as the unit is equipped with a fully automated system.
Q: ANDwhat kind is it? How many times have you had to use it? How many things could you run on it? How much did you spend? Would you buy one with more power next time, or is the one you have sufficient? What types of problems have you had with running it. Do your neighbors always ask to hook up to it?
I have a Generac 5500XL generator. It's been used on several occasions, the longest being 3 days after Hurricane Juan blew through Nova Scotia in September 2003.
Q: From what I understand, when the earthquake struck, the nuclear reactors had shut down (control rods were inserted). As a result, the power coming from the steam turbine generators were shut off.At the same time, the earthquake had knocked out Japan's power grid, so power coming from outside the power plant was out.Then the emergency diesel generators went into effect, but was knocked out an hour later as well, and people suspect it was from the tsunami.Would the disaster still have happened if they kept the steam turbine generators running (which means never shutting down the reactor via control rods), and water pumping, instead of shutting it down and letting the backup power direct the emergency cooling?
As you point out it was the double-punch of the earthquake and tsunami that caused the problems at Fukushima. The diesel generators were enough to handle the pumps to cool the reactor but then the tsunami came and swamped them. Shutting down the reactor after an earthquake is standard safety procedure. The diesel generators were designed to be a backup in the event of an earthquake. They functioned fine even after the huge quake. If the quake didn't occur, but instead the planet was just hit by the tsunami, the other planets in unaffected areas of Japan would still be operating so this means the engineers onsite could have jerryrigged something so that the pumps would be powered by the national power grid even if the diesel pumps were knocked out. Not shutting the reactors down would have resulted in even more radiation being released due to the damaged buildings and containment units.
Q: Hi, i have a peugeot diesel conected to an 8kw alternator via a lay shaft engine 2275rpm alt 1500rpm at 2250rpm engine produces max torque 70lb ft, alt should only need 33lb ft. under heavy load engine allmost stalls. I think i need avr control? Can you help with advice and componants? Many thanks Andre
You have to set up a speed control of some sort. There are electronic versions out there that run off the frequency of the alternator. They are not cheap. It is surprising just how much power is required to produce your desired electrical output. I have a large diesel direct coupled to a four pole alt.with mechanical speed control also for 1500 rpm for 50Hz 240V and have also found a little issue when welding with it. If the governor is set for the load it can over rev a bit - if set to be perfect without load it struggles to get back up to 230V if welding at 120A plus. It's been easier to live with it in the end. If you are stalling out you will have to do something about a reliable speed control - check out the quality alternative energy companies that actually install RAP systems and ask about the control setups they can provide for exactly your situation. Keep looking because there are systems that will fix your problem, and give you a very useful machine! Good luck.
Q: because generating electricity is not very efficient, coal being imported from bolivia etcDoes it matter how far the stations are apart?btw dieselectric means the locomotive isn't directly diesel-driven, but runs on electricity generated by a diesel-generator inside the locomotive
The advantages of dieselelectric outweigh steam, mostly due to the high maintenance required on coal-fired steam engines. Another large factor is the ability of electrical generator to drive the traction motors required to overcome the inertia of the enormous mass of the freight when the train is starting up. Efficiency is not simply the mechanical efficiency of the system, but the ability to maintain the system and adapt it to various tasks.
Q: Hi. I'm thinking about getting a 15KVA Cummins generator.I want to know how many hours can I run a Diesel Generator before I have to give it a rest? How many hours do I need to rest it before I can get it started again. I live in a hot and dusty area.I have heard that Diesel engines are happier if they are just kept running and they hate being turned off and on, is that true?Any help or insight would be appreciated.Greetings from Iran
you need to read the documentation. No such thing as a diesel that runs forever All engines need fluids checked. In generators, there is prime power and standby power. Your warranty will be different for each type. The prime units can run for very long times, but are more expensive and have oil adding systems, etc to automoatically maintain levels and things like that. The diesel engine can be shhutdown and restartted like a gas engine. The turbo and starter motor are the real reasons for not doing short starts and stops. Also, how much load/environment you put on the generator makes a difference in how long it can run too. They can run for a long time as long as they are checked and maintained.
Q: I inherited a never used generator from a family estate with no motor. After a tornado here last fall I've decided to build a gen-set with it and I have a few questions. 1) Does the 1800 rpm generator mechanical specification mean that the required engine rpm must be a minimum, maximum 1800 rpm or both? Could it be more or is the chance to ruin it a possibility? I want to stay safe.2) Obviously I'm assuming the 25 hp engine requirement is a minimum but how much bigger can it be without wet stacking problems?3) With these generator output specifications can I power my household without damaging anything?I was planning diesel (still researching brands) and connecting direct. Thoughts?
The generator probably has to turn at 1800 rpm to maintain the 60 Hz frequency spec. Thisis important in a TV set but I can't think of any where else it would be important. Slocks will be edpendent on line frequency but in an emergency you don' really care if you have a watch. Reet the clocks after the power returns. You will probably use minimum power during a blackout. You need light heat and a book which doesn't use much power. No Alfred Hitchcock or Ray Bradberry.
Q: As the generator is for emergency, so it stopped for long time and only run for preventive maintenance, so its not accomulate running time, what is the standard to evaluate the need for maintenance ?
First make sure the fuel is fresh periodically. Old fuel deteriorates makes it hard it start and run. Second check the oil see if it is clean, check the oil filter too. Third check the fuel filter, change once a year if not used because of bad / old fuel. Forth Check the out put of the engine / voltage / oil pressure / amperage / operating temperature / current fuses / transfer switches are working properly. Listen and make sure the engine is running smooth, no misses. Should be good to go then.
Q: I am designing the system to produce electricity for a computer room with 40 PC and 40 LCD screens. The needed power is about 15 KW (20 hp). My system consists of a compressor, a compressed air tank, a turbocharger and a mini gas turbine. I will talk a little bit about the operation: the air is released from the tank and driven by ducting system to turbocharger, at which the air flow is through turbocharger and run turbine to produce electricity. I have searched in internet many times about the turbine but still have no fit one. Can anybody suggest me one? And the turbocharger too if you don't mind. I really need all the details about both of them for calculations.
15kW gas turbine not as efficient, much noisier, more expensive, gearbox problems GO DIESEL

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products