power cable manufacturers Copper Core Heat-resistance 105oC PVC Insulation
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Product Description:
Specifications:
PVC/XLPE INSULATION POWER CABLE
State Grid
ISO 9001 standard
Internation compliance
2. Application:
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. The lead sheath brings an enhanced resistance to aromatic hydrocarbons.
3.Specification Size and Technical Data:
Model | Name |
BV | Copper Core PVC Insulation Wire |
BLV | Aluminum Core PVC Insulation Wire |
BVR | Copper Core PVC Insulation Flexible Wire |
BVV | Copper Core PVC Insulation PVC Sheath Round Wire |
BVVB | Copper Core PVC Insulation PVC Sheath Flat Wire |
BLVVB | Aluminum Core PVC Insulation PVC Sheath Flat Wire |
BV-105 | Copper Core Heat-resistance 105oC PVC Insulation |
Code Name | Nominal conductor area | Number of wires | Nominal diameter of wire | Nominal thickness of insulation | Approx. Overall diameter | Max. Conductor DC resistance at 20oC |
mm2 | No. | mm | mm | mm | Ω/km | |
H05V-U | 0.5 | 1 | 0.8 | 0.6 | 2 | 36 |
0.75 | 1 | 0.97 | 0.6 | 2.2 | 24.5 | |
1 | 1 | 1.13 | 0.6 | 2.3 | 18.1 | |
H07V-U | 1.5 | 1 | 1.38 | 0.7 | 2.8 | 12.1 |
2.5 | 1 | 1.78 | 0.8 | 3.4 | 7.41 | |
4 | 1 | 2.25 | 0.8 | 3.8 | 4.61 | |
6 | 1 | 2.76 | 0.8 | 4.4 | 3.08 | |
10 | 1 | 3.55 | 1 | 5.5 | 1.83 | |
H07V-R | 1.5 | 7 | 0.52 | 0.7 | 3 | 12.1 |
2.5 | 7 | 0.68 | 0.8 | 3.6 | 7.41 | |
4 | 7 | 0.85 | 0.8 | 4.2 | 4.61 | |
6 | 7 | 1.04 | 0.8 | 4.7 | 3.08 | |
10 | 7 | 1.35 | 1 | 6 | 1.83 | |
16 | 7 | 1.68 | 1 | 7 | 1.15 | |
25 | 7 | 2.1 | 1.2 | 8.7 | 0.727 | |
35 | 7 | 2.48 | 1.2 | 9.8 | 0.524 | |
50 | 19 | 1.76 | 1.4 | 11.6 | 0.387 | |
70 | 19 | 2.1 | 1.4 | 13.3 | 0.268 | |
95 | 19 | 2.48 | 1.6 | 15.6 | 0.193 | |
120 | 37 | 2 | 1.6 | 17.1 | 0.153 | |
150 | 37 | 2.22 | 1.8 | 19.1 | 0.124 |
- Q: Yjv22 what is the core of the cable? Copper core or aluminum core?
- YJ refers to the insulation material for the cross-linked polyethylene, V refers to the inner layer of PVC within the steel sheath armored copper power cable as aluminum core was YJLV22
- Q: I just recently bought an amp from my friend. It is a fender frontman 15 w amp. I think it is one of the ones that comes in the strat pack or something. anyway, she didnt have the power cable for the amp that plugs into the back, and i kind of need this. does anyone know where i can find one or buy it. I already looked at fenders websight. anything would helpthanks
- all i can suggest is try OKorder or your local music store, OKorder can be tricky because you could get one that gives distortion if it is not new, but if you are desperate, then OKorder or order one from your local music store.
- Q: What is the parallel use of the power cable
- Do not know what you want to ask? What about your situation? Normal or pregnant? Normal this radiation does not affect what, if it is pregnant, this is far away from the best. Pregnancy is most needed to stay away from the microwave!
- Q: so I bought a new power supply to go with my new case and motherboard, and when I recived the new power supply it didn't have a power cable That Plugs into the wall, can I use the one from my old power supply or will I have to get a new one? Cause I tried using it and my pc didn't turn on, or is my power supply that I got possibly dead?
- every power supply I've gotten for years uses completely standard, detachable power cords. I've never yet seen one that will not use the same cords as all the others. Use the one from the old supply
- Q: my amplifier s power cable is not long enough to reach battery . so is there any problem if i take another piece of power cable and then attach them ?
- If okorder /
- Q: Power cable inspection, how many meters should be sampled?
- installation quota: cable ZR-YJV-4 * 70 + 1 * 35 is a five-core cable, you can refer to sets of "copper power cable laying cable (section mm2 below) 120? Cable "quota, and the fixed sub-sub-multiplied by the coefficient 1
- Q: What is the difference between a YJLV cable and a VLV cable?
- The reason why the wire outside the casing, is to protect the wire insulation from external damage. And the wire laying in the cable tray. The bridge has been gas to the protection of the role, so no longer outside the casing
- Q: i just moved from canada to asia and the voltage in canada was 110 and here its 240 so i have a ps3 and i plugged it into a converter(converts voltage). After im done playing i noticed that the power cable is warm and you could move the two positive and negative prongs very easily as if they were about to come out of the cable. I have no idea what to do HELP!!!!!!!
- The ps3 supports both 120 and 220 Voltage.
- Q: I only see the power supply (with a cable to connect to the laptop), but I don't see the AC cable. In the specs it only says quot;Cables Included: 1x Power cable - 3 ft.quot;I want to know if it includes the whole charger, or just the power supply to connect to laptop.
- It includes the whole cable and adapter
- Q: I want to order a small 100 watt amp and needed to know if it can get powered by the head unit by connecting it with the rca cables.. thanks..
- The RCA cables do not supply power to the amplifier; they just carry the audio signal from the head unit to the amp. Your amplifier, regardless of its power rating, will need power and ground connections in addition to the RCA and remote outputs from the head unit.
Send your message to us
power cable manufacturers Copper Core Heat-resistance 105oC PVC Insulation
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords