Single Core PVC Insulated Cable 450 /750 V BV
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 30000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Single Core PVC Insulated Cable 450 /750 V H05V-U
Production Introduction for Single Core PVC Insulated Cable 450 /750 V:
Voltage Rate: 300/500V, 450/750V
Range of Nominal cross section: 0.75 mm2 ~ 630 mm2
Conductor: Class 1/2 Plain annealed copper wires, solid or stranded
Constructions Insulation: PVC
Core color: Brown, Grey, Black, Blue, Green/Yellow or others on request
Max. Operating Temperature: 70℃, can be 90℃,105℃ as per requirement
Packing: 100 meter/roll or as per requirement
Application for Single Core PVC Insulated Cable 450 /750 V:
These cables are used for general purpose, as building wire for power, lighting and control wire to electrical appliances, suitable for use in conduit and for fixed, protected installation.
Production Standard for Single Core PVC Insulated Cable 450 /750 V:
IEC 60227, BS 6004, VDE0281, GB/T 5023, JB/T8734
The Feature for Single Core PVC Insulated Cable 450 /750 V:
The cable can be of flame retardance, fire resistance and other property
Packing photo for Single Core PVC Insulated Cable 450 /750 V:
FAQ For Single Core PVC Insulated Cable 450 /750 V:
Q1:What is the Production Capacity for your factory?
About 100 kilometer every day>
Q2: What is the Minimum Order Quantity For Single Core PVC Insulated Cable 450 /750 V?
MOQ: 10000 meters for small size, 5000 meters for middle size, 1000 meters for big size
Q3:What is the delivery time for these cables?
10~15 working days
Q4: What standards is the product complying with?
We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.
- Q: i soldered in one of those ribbon cables on to my hp's laptop power button cause the old ribbon was failing. anyways i am having some issues with this new cable1 the laptop will power on by itself if i insert the ribbon into the motherboard connector2 the only way to power off the laptop is to remove the cable from the mother board connector and that means opening up the whole laptop3 like i said it will power on by itself so that means that i cant turn it on/off with the power buttonevery thing is soldered correctly i dont understand also i am not sure but does the cable have to be like the old one cause the new one i soldered in looks the same? could it be that it needs that one particular cable replaced again? please help me i am sad
- Time to hang up our computer repair skills and take it to a shop...
- Q: I'm looking to add another Light fixture on the other side of the garage, and wire it using the existing cable from the first light, I know running a normal power cable outside drywall is against code, but I've heard some people say you can use something like BX cable, or some metal encased cable outside of drywall and still be up to code? Is there a I can run this cable outside of the drywall using something like that, and if yes, what exactly would I need to use to accomplish this? I plan I running the wire from the right side of the garage door, up above the door, and to the left side of the door to install a matching light.
- Plastic grey conduit is the way to go easy to work with just need a hack saw and some glue
- Q: Does it also come with the cable that connects it to the monitor? Thanks!
- Yeah, it comes with a three prong power cable and a bunch of internal cables, one or two for the motherboard, one or two for graphics cards, and a bunch for drives.
- Q: I bought a used DVD player that didn't come with a power cord or power cable.On the back of the DVD player, the power cable input looks like this:__________|_o__|__o__)So basically it looks like the power cable should have two wires with one side being flat and the other end being a half circle.What is the technical name for this power cord so I can easily find it if I go to Radio Shack?Thanks.
- Ask for a 6 ft AC power cord. They come in a few difference shapes so just describe what you did here. If it helps reference Radio Shack model/catalog number #61-2878. Good luck!
- Q: I got two mobile GPS units for my car which use a mini USB interface for powering. One of the units didn't come with a cigarette adapter so I am trying to figure out how to power it. Can I just use a normal USB cable? I would tap the red wire into the fuse box in my car, and ground the black wire to the frame. So:-Can a mini USB cable handle 12V for ~5ft-Is that the right way to connect them?Thanks!
- no because it will explode it only takes 5 to 4.5 volts and 2 to 2.5 volts i recommend using 5 volts and 2.5 watts bye
- Q: Were can i get a power cable for a SNES I checked okorder and they say there discontinued.
- They're a great site, they clean and repair systems as well. I've bought and had things repaired by them before. It'll set you back $7.95 plus shipping however. Or if you have a regular AC adapter that fits, it works just as good as the SNES brand.
- Q: i would like to have my power cables and control boxes inside in one spot is this possible? if so how and how expensive would it be?
- You could use trunking for the cables, and for the control boxes if they are in the house you could hide them under a box which you could decorate to look like a parcel...personally I would paint it, but drill some holes for ventilation.
- Q: lost the original cable at a gig, but I have another cable. the outlet on the Behringer guitar amp reads quot;Use only with 250V fuse, but right above the outlet it reads 220-240 with a upside down triangle next to it (not sure if this represents volts or not...I know obviously V stands for volts, but this is a upside down solid triangle.)My power cable/cord that i found reads 10A 250VI know i should probably purchase one direct from the manufacture, but that is not possible right now. I have a gig coming up this weekend.thanks for any help.I also mention the original power cord was a two prong (that went into the outlet) - the one i might use is a 3 prong. will this still be safe? It does fit into the back of the amp perfectly.
- Assuming you're in a place where the outlets provide 220 to 240 volts, it's fine. The 250 volts on the power cord just means it's good for *up to* that.
- Q: So I have a ordinary pc with a 500gb seagate hardrive in...and I have another seagate hardrive I want to put in (also 500gb) but do I need the sata power cable since it is not the main hardrive or can I only insert the Data cable for the harddrive since I didn't get any cables with my hardrive do I need need both cables, the Data and power cables or can only use the data cable ?
- You always need a power cable as well. The power cables are part of your computer's power supply unit and are never being shipped with harddrives.
- Q: How to choose the type of street lamp cable specifications, anxious
- Horizontal laying of the cable within the cable, generally do not need fixed, natural laying can be. Vertical laying section of the cable within the bridge, with the need to match the line card, the use of tied rope (multi-purpose single insulated wire) one by one fixed cable, fixed spacing should meet the requirements. According to the control cable and the power of the different layers of laying, if the power cable to be multi-layer need to have 300mm spacing (or load capacity is large enough), if it is control cable, casually laying, if the laying of power cable laying below Layer, above the laying of control cable, but not too much affect the power cable cooling. If the high-voltage cable and low-voltage cable in principle do not allow common laying.
Send your message to us
Single Core PVC Insulated Cable 450 /750 V BV
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 30000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords