KYN18A-12 AC witdrawout metal-clad switchgear.
1. Model
Kmetal-clad and metal-enclosed switchgear
2. General
KYN18A-12 AC indoor withdrawout metal-clad switchgear is the central vacuum switch cabinet which mainly applies the ZN12-12 vacuum circuit breaker, but also can be equipped with ZN22B-12 vacuum circuit breaker and 3AF, 3AH vacuum circuit breaker of Siemens.
The product complies with the standard of GB3906-91 (3-35KV AC metal-enclose switch cabinet), the standard of DL4047-91 (indoor AC switch cabinet ordering technique) and the standard of IEC298 (AC metal-enclosed switchgear and control equipments). It is used in the AC 3-10 KV three-phase 50 Hz single bus power system to receive and distribute the power. It is widely used in various kinds of power plants, substation and industrial and mining enterprises. The product can be installed against the wall (not recommended) and non-against the wall installed
3. Technical parameters
Item |
Unit |
Value | |
Rated voltage |
KV |
12 | |
Rated frequency |
Hz |
50/60 | |
Rated insulation level |
1 min power frequency withstand voltage |
KV |
42 (isolation fracture: 48)
|
Rated lightning impulse withstand voltage |
75 (isolation fracture: 85)
| ||
Rated current |
A |
630,1250,1600,2000,2500,3150,4000,5000 | |
specified short circuit drop-out current |
KA |
20, 25, 31.5,40,50,63 | |
Rated short circuit making current |
KA |
50, 63, 80,100,130,160 | |
Rated short-time withstand current (4S) |
KA |
20, 25, 31.5,40,50,63 | |
Rated withstand current (peak) |
KA |
50, 63, 80,100,130,160 | |
Protection degree |
|
IP4X | |
External dimension (W*D*H) |
≤1250A |
mm |
800*1650*2200 |
≥1600A |
1000*1650*2200 | ||
Overhead inlet |
D:1800 |
- Q: I need the cable for my TV to be longer. It uses a 10A 125W cable, and all I can find (at a price I like) are 13/15A cords. Is it okay to use this in conjunction with the 10A TV power cable? It will be plugged into a surge protector if that makes a difference...
- The 10 amp and 13 amp ratings are just the maximum amount of current those cables are made for. Your TV will only use 2 or 3 amps, so both cables are fine.
- Q: I purchased a LCD TV the other day and ran a cable line to it (via crawl space). I had to use a splitter to connect the new TV. I connected the cable directly to the TV and then the power cable to the outlet which “popped” and the power went out (breaker trips). I connect the TV power cable to a surge protector and the power goes out again (surge protector wasn’t even on). So I disconnect the cable from the tv and connect the power. Everything is fine until I try and connect the cable...let’s just say the spark was bright and hot enough to melt part of the connector on the TV! So I return the TV and get a different brand and the same thing happens when I plug it into a surge protector. To begin narrowing out possible problems I connect the cable to a regular 10 year old TV with no problems. It is a brand new cable with no cuts or fraying. Any suggestions?
- Something is seriously wrong, and you may need to get an electrician on the problem. You need to check the voltage between your set and the cable with a meter. There should be little or no measurable voltage. If you are getting a reading like 115 volts, then I suspect that the wall outlet into which your TV is plugged has been wired backwards, i.e. the black wire is on the white terminal, and vice-versa. The cable is (or should be) grounded where it comes into the house, but if the outlet has the hot wire on the wrong side, this might cause the problem you described. The wrong connection could have occurred anywhere along the line between your main panel and the outlet, so this may involve checking the connections at several outlets and light fixtures - whatever is on the same circuit as your TV's outlet.
- Q: do i need to buy the cable that says specifically for ground? or can i just use my left over wiring from the power cable to connect in the ground? is there a difference between the two cables?
- Cable is cable, the only thing that matters is where it is connected to and where it is going. You do not want to hook ground where the power wire goes. The color codes is only convenience.
- Q: My computer speakers have a control tower(volume etc.) that plugs into the back of the subwoofer. I would like to move the tower further away from the sub then the cable allows. Is there an extension cable I could get?On the cable it says:2464 E205890 AWM 80C 300V VW-1SCThe end of the cable is round and has a row of two pins, then a row of 4 pins and then a row of 3 pins.
- For Extend Power Cable!?. Find correct extention any store tools category Or find in internet Searching. Good Luck. Comentary: Take precaution about Where install and take all the precaution. I remember to find one in Lowes
- Q: What models and specifications does the cable have? Do not understand the cable with the power cable is not the same thing, or contains the relationship?
- Wired do not need to set what ah, directly to the network cable can be inserted into the network port
- Q: I mean like the power connector cables. All power supplys have the same cables to supply power from the PSU to components right?
- no all smps don't have same cable you have to purchase same smps as you using right now or according to your motherboard
- Q: I recently bought a new internal hard drive for my computer (Hitachi Hds721010cla332, a upgraded version of what I currently have). When trying to install it I found out that the power socket isnt the same as my current hard drive. Ive been searching on the internet but cant find an adapter that converts from my current hard drives power cable to the new hard drives required power cable.
- That is a SATA hard drive and requires a SATA data cable and a SATA power cable. The long slot is the power connecter and the short slot is for the data cable. If you power supply does not have a SATA power connecter, all you need is a 4 pin molex to SATA power adapter. They are available at any computer supply outlet. Staples, or Office Depot, or any good computer repair shop should have one. The little port that you have circled in the photo does not need a connection.
- Q: I currently have a 250 watt 2 channel power cord and a 500 watt alpine amp with 2 12 inch mtx terminator subs..i am continuously blowing blade fuses and i ended up buying a 680 watt power cable. Will this blow out my amp or do any damage or will it be all good and give the maximum power my amp can supply? (Without exploding) just wondering thanks!
- no sir it will not, infact it may completly stop the problem, i would say to much current is passing through the wire, if the amp will accept the wire (even if its a tight fit) thats what your looking for. so to answer your question using the 680 watt wiring kit is just what you need and will be perfect, you could even get the 1200 watt wiring kit if need be, (assumikng you bought the schosche kit from walmart)
- Q: Whilst mowing the grass, I cut through the power cable, which was connected straight into the wall and not an adapter, which it usually is. I'm fine, how comes? The mower is a flymo bought last year.
- If you do not have an RCD cut out and were holding the plastic grip you were lucky, they are designed for this event but I always plug into a trip switch.
- Q: ok so i opend up my machine, and i bassicly took apart the processor and removed the dail up pci card thingy, then i put it all back together and i also took off the case, which meant removing all case power leads, quot;power SWand power led etc. but i put them all in the same place i took them out, well i think i did, theres so many different slots it they could go into, it would take at least 500 attempts to find the right slots for all, not to mention the fact i might blow the board. so has anyone got the manual for this motherboard. or no where to find an online one. cus i need to know where to plug them in. thanks
- hi bradley we have all been there before.... rebuilt a pc and forgot which connectors go where on the motherboard.... however if you go to your motherboard manufactuers website you should be able to download the motherboard manual which will have a detailed diagram showing you were each connector goes however in theory you can get away with just plugging in the power connector ( power sw ) ....and it wont do any harm trying each combination... however i would recommend trying the top row of pins... and make sure you insert the connector horizontally as you look at it for example check this image of the power sw connector properly connected ( img204.imageshack.us/img204/8682/... ) .....as you can see the power sw is using pins 3 and 4 on the back row of pins.... so give that a try firstas i stated you wont blow the board..... ive seen people use screwdrivers to start their motherboards .. and this is done by shorting two pins.... so theres no way you are going to blow your motherboard..... however i would try to locate your motherboard manual first.... and failing that try my method.... and a good idea is to draw a diagram of your motherboard pins ... then as soon as you have tried a combination mark it off.... at least this way you are not going to try the same combination twice i hope this has helped,any problems let me know good luck bradley !
1. Manufacturer Overview
Location | Jiangsu, China |
Year Established | 1995 |
Annual Output Value | USD200,752,660.10 |
Main Markets | Southeast Asia;Mid East ;Domestic Marke |
Company Certifications | ISO14001;ISO9001;OHSMS GB/T28001-2001; CCC |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shanghai |
Export Percentage | 70% - 80% |
No.of Employees in Trade Department | 21-50 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 360,000 square meters |
No. of Production Lines | Above 80 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | High; Average |
Send your message to us
Switchgear
- Loading Port:
- China Main Port
- Payment Terms:
- TT or L/C
- Min Order Qty:
- 1Set set
- Supply Capability:
- 1SET Per Month set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches