Fire Pump Red Electric High Quality Pump
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 1000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification
Company Introduction
My company has more than 40 years history, is the China general machinery pump industry association member units.
The company has organized product research and development team, experienced high, intermediate technical staff.Complete production and processing, inspection, testing (pump performance test platform), and other equipment, to ensure that product quality is stable and reliable.Over the department, provincial, municipal and industry product quality supervision and inspection (smoke), only one is qualified to go through.Timely quality perfect after-sales service in place, favored by the majority of new and old customers rely on and praise.
The company has successfully passed the national industrial products production license, ISO9001 quality system review replacement work.Relevant product standards (enterprise), metrology, standardization management system, etc., have been acceptance by the superior department in charge of the inspection.Related to product development, production management, sales and after-sales service, are performed according to the system management standard.
Product specification
Capacity: 126-5500m3 / h
Head: 59-100m
Speed: 585-2900r/min
Medium temperature: Less than 105 degree
Features
1. Hydraulic design with wide flow-path non-clogged structure ,allowed fibres(3 times
length of inlet diameter),particles(30% size of inlet diameter )
2. Excellent design,high efficiency and energy saving .
3. Double mechnical seals in series,made of hard alloy corrosive proof silicon
carbide,which is durable and .wearable ,that enable pump safely operation for more
than 8000 hours continous.
4. Compact structure, small volume, easy moved and conveniently mounted , no need build
pump house, greatly reduct the cost.
Application
Mainly apply to delivery sewage water ,waster water and rain water contains solids and
fibres:
*municipal project
*building construction
*residential area
*industrial sewage treatment
*eviroment protect
*mining
Pictures show
Transportation
- Q: Under what circumstances should we set up fire pool and fire pump room? Is it necessary to have a building?
- These facilities are available only in large public buildings.
- Q: Why does the pump decay when connected in parallel?
- Because a water pump has reached the rated parameters, the parallel is only "superfluous".
- Q: is there a surface water pump that can pump water from a 1000 foot well?
- If what you mean with surface water pumps are those pumps mounted on the ground to distinguish them from submersible pumps , yes there are surface pumps that can pump water from a 1000 ft well. These are the so called jet pumps or deep well pumps wherein part of the output water is returned back to the bottom of the well pipe through the space between the outer pipe casing and the inner pipe and passed through a venturi opening to create an upward water jet which will push more water upward.
- Q: When using a frequency converter to adjust the pump, what is the relationship between the change of the speed and the efficiency of the pump?
- First, the wind pumps such load is usually called square torque load, which is in a certain range of speed and torque is roughly proportional to the square of the speed of N, TL=kn^2, power and speed is proportional to the cube, the energy-saving effect is obvious. Can also be described according to what you pump model, the pump is divided into piston pumps, screw pumps, impeller pumps and centrifugal pumps.Secondly, under the standard condition, the higher the efficiency of the centrifugal pump, the higher the speed determines the size of the centrifugal force, the higher the speed, the greater the centrifugal force, and vice versa. Plunger pump and screw pump is not the same, the speed of speed and efficiency basically no impact. Third, in addition to buying the pump, you can let the manufacturer give you an FM curve, so you can see the frequency of mediation when the water pump efficiency changes
- Q: I have a 1995 Johnson 88 Outboard. It needs a water pump. I have everything loose except the shift rod that goes all the way through the unit How is it connected and how do I disconnect it?Thanks for your answers.
- some come apart on top of the gearcase somewhere
- Q: I getting some work done to my like replacing the timing cover gasket, oil pan gasket and the water pump gasket...the mechanic I talked to said I need to replace this as well; my thing is the water pump is fine..should I take his advice?
- When asking questions of this type, include the year make and model of the car. There's no reason on earth to replace a water-pump when all you need are the mating gaskets from pump to cylinder head or heads. Water-pumps don't have to be replaced until the weep-hole leeks coolant under the input shaft. Of all the things you had done, the water-pump is the first and easiest thing to be removed and replaced when and if the time comes.
- Q: i have an underground water tank, my jet pump went out again, got a new one, waiting for the guy to come install it. i got an old fashioned iron hand pump, for when the electric, or the pump goes out again, i can pump out water. got pipes, fittings, foot valve. i just dont know what kind of base to make ,to bolt pump to, over the pipe that will come out of the ground. any ideas?
- you can make a wooden floor cover using a treated good lumber of 1 X 6 for the floor and 2 X 6 lumber for the floor joist. assemble the 2X6 lumber for the floor joist. depending on the top area of your water tank. arrange the floor joist at 0.60 meter spacing and 1.2 meter braces. after that, use 1X6 lumber as flooring with at least 2 cm spacing between lumber. as on the base of your pump, you can reinforce it by adding 2X6 braces. use a lug bolt depending on the size of the slot at the base of your pump then bolt it on top of the 1X6 flooring. its better if we can draw it here to make it easier to understand and explain i dont know if this can help much because we havent seen the actual situation of your tank and your pump.
- Q: The garage told me my water pump was pumping quot;weaklyand needs to be replaced.
- A water pump can start to 'pump weakly' as the blades on the rotor wear out. That will reduce the amount of coolant that is being moved through the system. That causes the temperature to rise overall. Usually that does not happen before the bearing wears out. When that happens you will normally see some coolant dripping out of the weep hole of the pump if the pump is on the outside of the engine.
- Q: My 1998 Dodge Dakota V6 heater only gets warm, I have replaced the thermostat. I have back flushed the heater core. The heater hose coming from near the thermostat gets hot, but the hose coming from the heater core going to the water pump only gets warm. The large hose coming from the thermostat is hot near the engine, but is only warm near the radiator. Is the water pump bad? If I open the radiator cap there is no signs of circulation. How do I check the water pump?Thanks,Gene
- to answer your question directly, you can check a water pump the same on any car. water pumps have whats called a weep hole there is a small hole that is designed to leak coolant when your water pump seal goes out. find the pump and see if there is a trail of white from this 'weep hole' then yes your pump is bad. if not, i dont know the layout of the hoses for your car so i couldnt diagnose it for sure. but check your water pump for the signs i gave you. its a tell tale sign
- Q: I'm looking to build a fountain to dispense Wine. For which, I'll need a pump. I'm thinking submersible aquarium pump. I'm concerned about after tastes, and general safety of this venture. Can you drink water that's been run through an aquarium pump?Would alcohol be any different?Is there a better choice? What would it be?
- Its is safe to drink water pushed though it...but i would still rinse it first....it just an impeller powered my a magnet...it should work for what you want but it needs to be small...i would think like 20 or 30 gallons per hour
Send your message to us
Fire Pump Red Electric High Quality Pump
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 1000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords