• Factory price china yuchai diesel generator sets 220kw System 1
Factory price china yuchai diesel generator sets 220kw

Factory price china yuchai diesel generator sets 220kw

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
300 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

open type dioesel generator with yuchai enginee 
1) Factory direct sale 
(2) CE, ISO9001 quality 

Power range

18-650KW

Engine

All series powered by Yuchai engine

Alternator

All series owning alternator options of Stamford/Marathon/ENGGA

Controller system

Hanging control box, automatic control module Smartgen HGM6310

Base frame

International channel steel welded base, inbuilt composite damping system; sandblast, acid-washing, antiseptic treatment

Radiator

Standard genset-joining radiator of 40 °C ambient temperature

 

 

Diesel generator Powered by Yuchai Engine,which yuchai is a large state-owned enterprise and a Nasdaq listed company in USA (NYSE:CYD). Its main business covers diesel engine, contruction machinery, vehicle parts. The engines produced by Yuchai include series YC6G, YC4G, YC4E to which American technology applied, series YC6A, YC6B, YC6J, YC4B, YC4D, YC4F, YC4W to which German technology applied, and YC6M series in which world top technology integrated, totally 12 series.

FKS-Y220220275YC6M350L-D206≤1973100*1100*17502800


Q: Hi. We're off grid and therefore installing a 3 phase Diesel generator. Each phase is rated at 20 Amps continuous(23 Amps max). we want to run 3 Split type ACs, one on each phase, plus some other small appliances.Our problem is that each AC has a start up current of 20 Amps, which will trip the safety circuit on the generator everytime it comes on.The ACs running current is only 8 Amps, but jumps to 20 Amps for a split second everytime the Compressor comes on.Is there a simple way to control the start up current on the ACs? I read something about putting a coil of wire on the input of the Compressor. I tried that with a water pump just to check if it works. The surge current was still there.Any ideas if I can use a Capacitor? If yes, can you tell me what capacity I should use? If you give me the formula I can figure it myself. We run on 220-240 Volts, 50 HZ.Thanks for your answers.
Is it too late to switch to a 240 volt single phase generator of the same capacity? This would have a 60 amp capability and would handle the surges with no trouble. I don't see how a capacitor will help. If you are stuck with the 3 phase generator, perhaps you can switch the ACs for ones with 3 phase motors. That will spread the surge over the 3 phases. There are also soft-start ACs .
Q: Can anyone help me figure out where I can find a diesel motor that can be used in a motorcycle? Can I take the motor out of a diesel generator or should I buy a new/used one made specifically for a motorcycle?
diesel motors are not exactly meant for huge changes in load and very high revs typical of a motorcycle a diesel generator? those run in a very very narrow powerband go for the one made for a motorcycle if their are any unless you have a really good reason just get a 4 stroke
Q: I drive a TATA Indica DLS (not turbo), I understand that it has a base diesel engine which has 55 bhp. I have heard that CNG kits are available in the market and CNG is much economic and eco friendly. Please comment if you know about it. Is it possible ? and how much will be the cost for the conversion ? What are the steps involved ?
you incredibly choose a sparkling engine altogether, one designed to reliably run whilst offering the intense compression ratios like 22:a million mandatory to assist combustion of diesel or different oils. gas engines are purely sturdy for 10:a million compression presently. If the vehicle is already a ordinary diesel vehicle, i've got self assurance all you pick is a few further gas filtering to run on so reported as bio diesel.
Q: I need a silent diesel generator of power capacity of 25 kW, i am going for the following brands(suggest something)1. Jackson Cummins2. Mahindra powerol3. Kirloskar
i have seen Kirloskar unit in an office complex. Seems to be good. No idea about the other two brands.
Q: HI FROM NEW ZEALAND.I HAVE A LISTER-PETTER 16 KVA DIESEL 3 PHASE GENSET WITH SINGLE PHASE SOCKET @ 240 VAC. WITH A ITALIAN ELECTRONIC DIAGNOSTICS CONTROL PANEL WITH BREAKERS ETC.WHEN RUNNING A ESAB CADDY PROFESSIONAL 140 INVERTER WELDER @130 AMPS USING 4 MM HARDFACING RODS, ON FIRST STRIKE THE GENSET CUTS OUT AND DIE.WHEN USING A COPPER WOUND TRANFORMER WELDER THE THING RUNS WELL BUT WILL NOT STOP WHEN I HIT THE KEY TO TURN OFF OR EMERGENCY STOP BUTTON.NOTE; THIS IS A STANDBY GENSET IN THAT I JUST PLUGGED IN A WELDER, THE GENSET IS NOT A DEDICATED WELDING GENERATOR.I USED OTHER DIESEL GENSETS PRIOR WITHOUT ANY PROBS.WILL ANY1 HAVE ANY CLUES? REGARDING THIS.THANKS IN ADVANCE.CHEERS CARL GIN
Does the Esab welder have high frequency? If so the high freq. is feeding back into the generator and frying the electronics. You may need to have the generators repaired. The only way to prevent damage is to turn the high freq. off, or drive an earth ground as close to the welder as possible and you have to run a wire to your grounding clamp to this ground and the machine ground needs to go to this also. You have to get the high freq. out of the circuit as quick as possible. (I have a Hobart Champion Fabshop that is notorious for this.)
Q: I am investigating CoGen engine applications. I am looking for about 100-150kWh power output plus heat (water). Do you know of any application that uses solar thermal energy to power the engine? Also, it seems most CoGen engines use natural gas or other gases, but gas would not be viable for my application. Diesel would most likely be the second best option. Do you know of any diesel coGen applications?Please list vendors or prices.Thank you
Create okorder
Q: I want to know if someone put gasoline instead of diesel in my generator. I'm use to seeing dark yellow fuel in it and now the muffler is red hot
Well I remember my Dad had purple diesel on the farm. Everclear is a great band. My favorite song by them is AM Radio.
Q: i want to buy a generator for our company i want to know how to calculate current for 1000kva capacity generator. and also want to know control and protection are required for the same generator please explain.
Depends on the use of the generator. Power and current are related. Divide the rated power of the generator( I assume is diesel driven) by the voltage of the area where you operate (Europe is 240) so 1000000 VA: 2404,166 ampere in the most favourable conditions (Power factor 1) usually the current value is multiplied by .7(Minimum Power Factor acceptable) which will give you a maximum continuous current of circa 3500 ampere. If you are using the generator for emergency you require an automatic starting system and a priority circuit together the standard protection panel which include: 1 Over and Under voltage protection 2 Over and Under frequency protection 3 Phase sequence 4 Overload. Most of these panels have other functions as well. If you require more information than what I have written, I suggest you look at some of the leaflets provided by manufactures
Q: I have a 1992 chevy 250 with a 6.5 turbo diesel, I have built a hydrogen generator for it that produces 2lt./min. but do not know how to hook it to the truck or where before or after the turbo.
You should hook it up before the turbo. After the turbo is pressurized which will make it hard to feed the gas in.
Q: I have a Powermate Maxa 5,000ER generator need to know how to start it, it is 14degrees here right now. Thanks.
Coleman Powermate Maxa 5000 Er

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches