• Double cage material hoist SC200/200G System 1
Double cage material hoist SC200/200G

Double cage material hoist SC200/200G

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

  • Condition: New

  • Place of Origin: Guangdong, China (Mainland)

  • Brand Name: TW

  • Model Number: SC200/200G

  • Rated Loading Capacity(kg): 2*2000kgs

  • Hoisting Speed: 0-96m/min

  • Max Lifting Height: 500m

  • Dimension(L*W*H): 3.2*1.5*2.1m

  • Loder Weight: 2*2000kgs

  • After-sales Service Provided: Engineers available to service machinery overseas

  • cutomized: color

  • cage inner size: 3.2*1.5*2.1m or customized

  • mast size: 650*650*1508mm

  • frequency inverter: yes

  • safety device: SAJ50-2.0

  • motor: SEW from Germany

  • voltage: 380V/415V or customized

  • inverter power: 2*110V

  • motor power: 2*3*18.5kw

  • counter weight: no


Q: Is there a beam plate template that is used to calculate the engineering quantity of the beam formwork or the engineering quantity of the beam and the plate? Urgent thank you
As long as the board and the board together (usually for the plate in the beam), together with the count; not together with the other
Q: How to do irrigation formwork
Pro, beam section is marked on the drawings, the beam is 200*500.
Q: What is the meaning of the steel beam overhead on the top of the beam formwork
That is, after the formwork is supported, the upper part of the formwork is bound with steel bars (usually on the floor)The reinforcement of the ground beam is the first reinforcement and then the template
Q: Which part of the middle beam and side beam in the T beam template? Thank you
So there are [side span beam], [cross the middle beam], [medium span beam], [across the edge beam] four kinds of distinction. The amount of concrete, steel is a little different
Q: The bottom of the board 12.24*7.44 why not *2 floor 12.24 of the two of the 7.44 also have the plate side mode *2 is * of the two or both
The board side mode *2 is the circumference of the board (minus column protruding part) multiplied by the thickness of the plate 0.1m.
Q: More than the number of square cross-section of the beam high formwork
According to the "dangerous method" sub project safety management of the construction quality of [2009]87, the height of more than 5m, the total construction loads greater than 10kN/m2, or the template support system concentrated line load greater than 15kN/m to prepare special construction scheme
Q: The area of the beam template = (both sides of the high and low beam) * beam lengthWhat do you mean by the two words in the brackets?
Calculation of contact area between concrete and formworkPillar: circumference multiplied by the column height, from the pile or board surface of a first floor surface, non beam plate count to the bottom of the column cap
Q: How to support 6m arc beam template how to set up?
6m beam if the horizontal direction of the arc beam, when the template is located at the end of the mold and the side of the mold is a patchwork way to support the mold, the arc is not small 500mm or 1000mm together, if the arc is large 300mm or 200mm together
Q: A set of 50 m T beam steel template weight
So this set of semi T beam template, the general weight is between more than and 60 tons to seventy tons. A little hope to adopt
Q: How to calculate the intersection of rectangular column and beam
Plate and beam plate:(1) the calculation of the area of beam and plate according to the area of beam and plate;(2): high beam plate girders according to the amount of height of sheet thickness calculation;(3) a long beam plate girders: beam to column connection, the length of the beam to column side; girder transfer, beam to beam side.(4) the calculation of the area of the plate and column cap without beam(5) the area of the beam connection is not deducted, and the beam head area is not increased

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords