China Different Types of Three Phase 5 Core pvc Insulated Power Cable

China Different Types of Three Phase 5 Core pvc Insulated Power Cable

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
50000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

Place of Origin:

Zhejiang, China (Mainland)

Brand Name:

cnbm

Model Number:

VV YJV VV22 YJV22 VV32 YJV32 VV62 YJV62 VV72 YJV72 YJLW02 YJLW03 KVV

Insulation Material:

PVC or XLPE

Type:

Low,Medium and High Voltage

Application:

s electric power distribution networks or industrial installations

Conductor Material:

Copper or Aluminium

Jacket:

PVC or PE

Filler:

Non-hygroscopic Polypropylene(PP)

Binder Tape:

Non-woven fabric

Metallic Armour 1:

Galvanized Stainless Steel Tape Armour(STA)

Metallic Armour 2:

Galvanized Stainless Steel Wire Armour(SWA)

Metallic Armour 3:

Non-magnetic Steel Tape Armour(only for single core)

Metallic Armour 4:

Aluminium Wire



Packaging & Delivery

Packaging Details:wooden drum; iron-wooden drum or steel drum
Delivery Detail:Depending on the quantity

Specifications

2015 new product electric power cable 
1 Conductor:Copper or Aluminium 
2 Insulation:PVC or XLPE 
3 Voltage:Low/Medium/High Vol

2015 new product electric power  cable  

Technical Parameters of our Power Cable 

1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890

2). Detailed description or construction:

    * Conductor: compacted or uncompacted copper or aluminium

    * Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)

    * Filler: Polypropylene filament with lapped binding tape

    * Binder: Binding tape

    * Inner sheath: Polyvinyl chloride (PVC)

    * Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)

    *Sheath: Polyvinyl chloride (PVC)

3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:

    U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV

4). Voltage:

     0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV

    In the voltage designation of cables U0/U(Um):

        * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;

        * U is the rated power frequency voltage between conductors for which the cable is designed;

        * Um is the maximum value of the "highest system voltage" for which the equipment maybe used.

5). Application:

     For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.

6). Marking: According to the customers' requirements

China Different Types of Three Phase 5 Core pvc Insulated Power Cable

China Different Types of Three Phase 5 Core pvc Insulated Power Cable

China Different Types of Three Phase 5 Core pvc Insulated Power Cable

China Different Types of Three Phase 5 Core pvc Insulated Power Cable

China Different Types of Three Phase 5 Core pvc Insulated Power Cable

China Different Types of Three Phase 5 Core pvc Insulated Power Cable

China Different Types of Three Phase 5 Core pvc Insulated Power Cable

FAQ

·         Can we make an OEM order?

o    We can offer or supply goods as customers' requirements.

·         How can I get some samples? Free or not?

o    We can send some normal samples, absolutely free.

·         How does your factory do regarding quality control?

o    "Quality is priority." We always attach great importance to quality controlling from the very beginning to the very end. Our factory has gained ISO9001 , SGS authentication, CE for Europe, etc.


Q: i bought a record player at a garage sale. it is the kind that has to be hook up to a sterio (no speakers of its own). it has the two cables to hook up to the sterio but no power cable. will the power come from the sterio or did i get ripped off?
You need to get a power cable. If you do some research online maybe you can find the manufacturer of the turntable. It may be a common type cord or maybe not. If you e-mail me maybe I can help more.
Q: My laptop works gr8, but the power cable when plugged into the machine is quite loose and just falls out sometimes which is very annoying. Has anyone with this laptop had the same problem and fixed it? if so how? an what do you think i can do to fix it?
contact dell maybe theyll help u
Q: I have an electrical source 220 Kv or 380 KV at site X and want to pull cables to site Y to privde electricity for this Y site for general lighting and power sockets.So what is the max distance for the cables i can pull from site X without voltage drop affect the voltage or power at site Y.
You are not providing enough information. 220 KV can provide power of TENS of miles on reasonably modest cable PROVIDING the current drain is not too high. Sorry but the idea of anyone playing around with almost .4 MV without the first idea about loading / cable diameter / insualtion requirements scares the crap out of me! Without the required information, all I can say is With the right cable at 380KV , hundreds of miles As an aside, if this is a temorary site, then the cost of buying generator will be WAY cheaper than the cost of the cable and transformers you wil require to turn 380Kv into 110 / 220V If a permenent fixture, then suggest for normal lighting and sockets (as in no industrial smelting plants!), then you would eed to be dropping the voltage either at the 380kv site OR at least some distance from the new fixture. Houses do not typically have .4 MV coming into the cellar. It might arc a few metres you see if the air is a little humid. Make things a bit dodgy. **UPDATE** Ok, thanks for clarifying the voltage. Now we also know power too -so at 220v, and about 12KW we are looking at VERY roughly 55 Amps. 25mm cable ought to be good for a couple of hundred metres or so. 16mm for upto 50 metres or so. If a LOT further than that, then either go with three phase/380 OR up the size of the cable. Problem is it can start getting pricey. The shorter the run, the lighter the cable can be - to a point - would NOT suggest going below 10mm under ANY circumstances. You will always get SOME voltage drop, but providing it is in the order of a couple of volts here and there, there is no appreciable waste / heat generation. Is this a fixed installation or a temporary one - if temporary and a fair distance away I would STILL be inclined to sugges a genset hire might work out cheaper than drums of suitable cable.
Q: Hey, my parents just bought me a turntable and I have no idea where one of the cables would go into a normal stereo or what I might need to buy to be able to plug it to a normal modern stereo.
Everyone okorder , though.
Q: I have an old scanner, HP Scanjet 3400C, but I have lost the power supply cable. The power socket the cable fits into looks like a small single hole with a little pin in the middle.Can I replace it and what is it called?Thank you very much.
The power cable and adapter will probably be unique to the scanner. You'll have to order the right one from HP, or through a computer store. The USB cable should be standard. Most printers and scanners use a USB cable with a Type A connector (flat) on one end, and a Type B connector (squared-off) on the other end. They're easy to find at Staples, as well as at computer stores.
Q: I am currently travelling in Europe and my power cable crapped out. I need a website which offers next-day international shipping. I am currently in Prague and am going to Krakow next; so if you know of a store in either city which would save me the shipping costs, that works, too.
polish okorder / all apartments have printers regards
Q: I just purchased and mounted my 52lcd and I cut holes to run the HDMI cables behind the wall. As I was snaking the power cable, I realized this might not be the best way. Is there anything I need to do (I only have basic 'contracting' skills) to keep my install fire code safe?
The hole should be sealed for a fire stop.That little hole should not amount to anything.If you seal the hole and have a problem with the tv set you are really going to have problems removing the set for service.
Q: Someone gave me a KDSusa LCD monitor. It doesn't have the usual spot on the back of it for me to plug in a power cable. I've never seen a monitor without the power cord plug in the back. There's a hole/plug on the side of the blue part that goes into the computer...I thought maybe that's where a some sort of power cord would go but I'm not sure. HELP!
check the site for your model screen to find the right power supply.
Q: Power cable casing buried what are the requirements
2 direct laying cable way, should meet the following requirements: 1 cable should be laid in the trenches, and should be along the length of the cable on the next, next to the side of the shop with a thickness of not less than 100mm soft soil or sand 2 along the length of the cable should cover the width of not less than 50mm on both sides of the cable protection board, protective board should adopt concrete 3 urban cable buried in the laying, it is appropriate in the protection board laying eye-catching signs 4 in the suburbs or open areas, along the cable path of the line spacing of 100m, corner or joint parts, should be erected obvious signs or signs 5 when the use of cable through the corrugated pipe laying in the trenches, should be along the full length of the bellows casting thickness of not less than 100mm of concrete, the width should not be less than 50mm outside the tube, the cable can not armor 3 buried in the non-frozen soil area, the cable embedding depth should meet the following requirements: 1 cable to the basement of the basement structure, not less than 03m 2 cable skin to the ground depth, not less than 07m; when located in the carriageway or farmland, should be properly deepened, and should not be less than 10m 4 buried in the permafrost area, should be buried below the permafrost layer, when not buried can be buried in the soil drainage of dry frozen soil or backfill, but also take other measures to prevent damage to the cable The 5 Directly laying the cable, is strictly prohibited in the underground pipe is just above or below The minimum distance between cable and cable, pipe, road, structure, etc shall be in accordance with Table 535 Table 535 Permissible minimum distance between cable and cable, pipe, road, structure, etc (m)
Q: The difference between a fire resistant cable and a general power cable
The domestic general by the following parts in order, some parts can be omitted: 1: category, use the first letter with the Chinese alphabet, such as K on behalf of the control cable, C on behalf of the marine cable Q car ignition line D power cable Y Mobile rubber sheathed cable H welding machine cable 2: conductor with the first letter of the Chinese alphabet said: such as T for the copper, L for the aluminum LG for the ACSR 3: Insulation material with the letter code, such as V for the PVCY Polyethylene 4: Sheath with the letter of the letter code with 35: feature code used in the first letter of Chinese spells, such as the circle with R, soft R, flat B, flat with B6: outer sheath with the number that: 22 the first representative of the steel armor, the second representative of the PVC jacket 7: derived code with a number or symbol, such as BV-withered Sichuan Fen boil let go wind sand dust 90 said temperature 90 degrees BV line can be omitted Generally have: D power cable T copper R round like VV. you control the order of the above carefully understand, which omitted the 1.2.5 three, you should see clearly.