• various types of pvc insulation power cable System 1
  • various types of pvc insulation power cable System 2
  • various types of pvc insulation power cable System 3
  • various types of pvc insulation power cable System 4
various types of pvc insulation power cable

various types of pvc insulation power cable

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
200 m
Supply Capability:
20000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Voltage: 1kv to 35kv
2. ISO, CCC Certificate
3. 22 years producing experience
4.Professional service

We can customize various types of cable in accordance with your requirements

XLPE  /PVC insulated power  cable

Mode and name

 Power cable

Model

                       Name

YJV

YJLV

CU or AL conductor ,XLPE/pvc  insulated PVC sheathed electric cable

YJV22

YJLV32

Cu or Al conductor XLPE /pvc insulated steel tape armoured ,steel wire armor

pvc sheathed electric cable

 We can produce 1kv up to 35kv power cable

 

XLPE insulated power cable 0.6/1kv
norminalsectional area insulati-on thicknessheath thickness(mm)

overal diameter

of cable (mm)

D.C resistance of conductor(km)                current rating
in air(A)direct in soil(A)
cuAlcuAlcuAl
1×1.50.71.56<=12.1< span=""><=12.1< span="">30254535
1×40.71.57<=7.41< span=""><=7.41< span="">45356050
1×60.71.57<=3.08< span=""><=4.61< span="">55457055
1×350.91.512<=0.524< span=""><=0.868< span="">175140190150
1×5011.513<=0.387< span=""><=0.641< span="">210170225180
1×701.11.514<=0.268< span=""><=0.443< span="">270215280225
1×951.11.516<=0.193< span=""><=0.320< span="">340275335270
1×1201.21.518<=0.153< span=""><=0.253< span="">400320380305
1×1501.4221<=0.124< span=""><=0.206< span="">460370425340
1×1851.6223<=0.0991< span=""><=0.164< span="">530415480375
1×2401.7225<=0.0754< span=""><=0.125< span="">625490555435
3×1.50.71.510<=12.1< span=""><=12.1< span="">25253030
3×2.50.71.511<=7.41< span=""><=12.1< span="">30253530
3×40.71.512<=4.61< span=""><=7.41< span="">40305040

Attention: We can provide more info than above data, if needed.The above are just some examples.

The desprition of 1kv copper xlpe insulated power cable

Characteristics of Cable

 1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C

 2.Installing temperature of cable should not be less than 0°C

 3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.

 4.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)

 5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.

Type and Specifiction

 

PVC Insulation Electric Cable

TYPE

Description of Cable

 

Main Applications

 

CU core

AL core

VV

VLV

Copper/Aluminium core,PVC insulated,PVC sheathed power cable

Non-armoured PVC cable are suited for laying indoors,In cable trench,On cable racks and in pipes. Unable bear external pressures and tensions.

VY

VLY

Copper/Aluminium core,PVC insulated,PE sheathed power cable

VV22

VLV22

Copper/Aluminium core,PVC insulated,steel tape armored,PVC sheathed power cable

Steel-tape armoured PVC cables are suited for vertical burial.Can bear moderate positive pressures,Unable bear tension forces.

VV23

VLV23

Copper/Aluminium core,PVC insulated,steel tape armored,PE sheathed power cable

VV32

VLV32

Copper/Aluminium core,PVC insulated,thin steel wire armored,PVC sheathed power cable

Thin steel wire armoured PVC cables are used in case of great difference of levels or vertical installation and Can do vertical burial.Can bear moderate positive pressures and tension forces.

VV33

VLV33

Copper/Aluminium core,PVC insulated,thin steel wire armored,PE sheathed power cable

VV42

VLV42

Copper/Aluminium core,PVC insulated,thick steel wire armored,PVC sheathed power cable

Thick steel wire armoured PVC cables are suited for vertical installation and can be laid water or sea-bottom.Can bear greater positive pressures and tension forces.

VV43

VLV43

Copper/Aluminium core,PVC insulated,thick steel wire armored,PE sheathed power cable

 

XLPE Insulated electric cable

Type

Description

Application

Cu Core

Al Core

YJV

ZR-YJV

YJLV

ZR-YJLV

Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable

Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable

Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force.

YJV22

ZR-YJV22

YJLV22

ZR-YJLV22

Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable

Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable

Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force.

YJV32

ZR-YJV32

YJLV32

ZR-YJLV32

Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable

Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable

Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force.

YJV42

ZR-YJV42

YJLV42

ZR-YJLV42

Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable

Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable

Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force.

 

Q: I got a XFX radeon 5750 graphics card and after a lot of trouble I realized that I hadn't plugged in the 6 pin PCIe power cable, but I don't see any slots on my power supply, does anyone know how to fix this problem? I really don't wanna buy another power supply :(
you okorder /... Scott ***Update*** only buy the cable i listed if you dont have the adapter from xfx....look through the box it was packaged in...if you still have it......
Q: when i bought my motherboard it came with two 4-pin to sata power cables but i see that the power supplies have a sata power cable on it how do i connect these i have no idea how to do this
I wonder what type of SATA hard drive Thomas has.
Q: I just recently purchased a PowerColor AMD Radeon HD 7850 graphics card (which didn't come with a power adapter cable) amp; needing to know what the power adapter cable looks like. If anyone could possibly send me a link with a picture, that would help out a lot.
6pin okorder /
Q: Beginner cost, do not know how the calculation of power cable works, is directly from the drawings on the amount of it?
The first is to buy a computer connected to the TV dedicated audio and video lines, length specifications are: 1.8 meters, 5 meters, 10 meters, 15 meters and 20 meters, etc., everywhere sold here do not do a detailed introduction to the first step: , S-terminal video cable connection S plug the end of the line into the video on the S terminal port, while the other end of the S-terminal line into the TV behind the S terminal port, the connection is completed (Figure 1); if you You can use the "S-AV adapter" supplied by OUR to connect the S-terminal connector to the S-terminal cable, and then insert the AV head of the other head into the AV video input after the TV Mouth, the connection is completed (Figure 2). . the audio cable connection will be the audio line of the two Lotus head were inserted into the TV after the left and right channel audio input port, while the audio cable 3.5mm audio head into the audio card audio output port, the connection is completed. If you need to use the "one sub-two audio frequency line", then its 3.5mm audio head into the audio card audio output port, speakers (headphones) and audio lines were inserted into the "one two audio frequency line" 3.5 Encyclopedia of Germany, Germany and Germany Bao Bao mother on the mouth, the connection is completed
Q: i have a modular power supply i lost my cables moving out of my old house. so can any one tell me where i can get new ones to my power supply:
I don't think you can, really... Modular power supplies come with cables, they are not one size fits all, every brand and even every model might have different cables and plugs. Contacting the manufacturer will be your best bet, but it might not be worth it, might as well just buy another power supply, it's only another $45 shipping and all.
Q: for any SATA 2 HDD, the power connector is longer. compared to the data transfer cable. wht is it so?,-------------- ,------the first set of lines represent the power connector second; the data connection cable.
at the same time as you're meaning are you waiting to boot off of the IDE stressful stress and get get admission to to the Sata stress, the answer is for particular. really connect the SATA stressful stress, and make positive the BIOS settings are set to boot from the IDE stress.
Q: some one told me that cisco get this router without AC power it get the power from the network cable?
You need to make sure your Switch supports POE (power over Ethernet).
Q: Power cable casing buried what are the requirements
2 direct laying cable way, should meet the following requirements: 1 cable should be laid in the trenches, and should be along the length of the cable on the next, next to the side of the shop with a thickness of not less than 100mm soft soil or sand 2 along the length of the cable should cover the width of not less than 50mm on both sides of the cable protection board, protective board should adopt concrete 3 urban cable buried in the laying, it is appropriate in the protection board laying eye-catching signs 4 in the suburbs or open areas, along the cable path of the line spacing of 100m, corner or joint parts, should be erected obvious signs or signs 5 when the use of cable through the corrugated pipe laying in the trenches, should be along the full length of the bellows casting thickness of not less than 100mm of concrete, the width should not be less than 50mm outside the tube, the cable can not armor 3 buried in the non-frozen soil area, the cable embedding depth should meet the following requirements: 1 cable to the basement of the basement structure, not less than 03m 2 cable skin to the ground depth, not less than 07m; when located in the carriageway or farmland, should be properly deepened, and should not be less than 10m 4 buried in the permafrost area, should be buried below the permafrost layer, when not buried can be buried in the soil drainage of dry frozen soil or backfill, but also take other measures to prevent damage to the cable The 5 Directly laying the cable, is strictly prohibited in the underground pipe is just above or below The minimum distance between cable and cable, pipe, road, structure, etc shall be in accordance with Table 535 Table 535 Permissible minimum distance between cable and cable, pipe, road, structure, etc (m)
Q: The Leader of the band inists that all power cables connected to the amplifires be placed away from the performance area.
1. People come to see the performers not cables. Keeping them out of sight makes a better presentation and is safer for the performers. 2. Keeping the power cables away from the audio cables is just good practice. Low level (mic and line level) signals from mics and instruments are no match for high current power cables. The high current power cables produce magnetic fields that can induce hum into low level audio cables. Balanced cables, ones that use 3 pin XLR connectors are better than unbalanced RCA or phono plug audio cables. In the real world audio cables do have to cross power cables. When this happens try to cross them at 90 degree angles. Try to keep power and audio about a foot apart if possible. You may not be able to do this 100% of the time, but the better you run your cables the better the sound will be as far as hum is concerned. Hope this helps. D.bumstead
Q: I just finished building my shed, I put a 1 1/2 inch conduit under the shed coming up into the corner. I am now about to dig the 65 foot trench back to the house. I need to run power, not a problem. I want to run a phone line, a network cable, and a cable wire for my satellite. I say shed but it is 12 by 20 feet with an attic. Can I run these additional lines in with the power. I was thinking about using a run of Shielded cables for the network and one for the phone. For the cable some heavy duty quot;I don't know what thoughquot;. Will the power lines mess the data up on them? What will work for the three if any. If I need to I could run them in a new conduit, but that is not cheap!
Congratulations on finishing your shed. Unfortunately, you can't run your communications wiring in the same conduit as a power line. It's against code and it will mess with your low-voltage signals. You'll need to run a separate piece for those. Keep it one foot away from the power conduit, crossing at right angles. Of course, you can run them closer for short distances, but keep it to a minimum. Bear in mind that no matter which satellite cable you choose, it won't like sharp turns. Running shielded cable for the network is a great idea. Also, network cable is getting better every day, run the most highly rated you can afford and you won't regret it. I would not recommend looking for any all-in-one cable. They often are not as well designed as the individual ones. Personally, I would run extra lines now, for future expansion. Hope this helps.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords