various types of pvc insulation power cable
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Voltage: 1kv to 35kv
2. ISO, CCC Certificate
3. 22 years producing experience
4.Professional service
We can customize various types of cable in accordance with your requirements
XLPE /PVC insulated power cable
Mode and name
Power cable
Model | Name |
YJV YJLV | CU or AL conductor ,XLPE/pvc insulated PVC sheathed electric cable |
YJV22 YJLV32 | Cu or Al conductor XLPE /pvc insulated steel tape armoured ,steel wire armor pvc sheathed electric cable |
We can produce 1kv up to 35kv power cable
XLPE insulated power cable 0.6/1kv | |||||||||||
norminalsectional area | insulati-on thicknes | sheath thickness(mm) | overal diameter of cable (mm) | D.C resistance of conductor(km) | current rating | ||||||
in air(A) | direct in soil(A) | ||||||||||
cu | Al | cu | Al | cu | Al | ||||||
1×1.5 | 0.7 | 1.5 | 6 | <=12.1< span=""> | <=12.1< span=""> | 30 | 25 | 45 | 35 | ||
1×4 | 0.7 | 1.5 | 7 | <=7.41< span=""> | <=7.41< span=""> | 45 | 35 | 60 | 50 | ||
1×6 | 0.7 | 1.5 | 7 | <=3.08< span=""> | <=4.61< span=""> | 55 | 45 | 70 | 55 | ||
1×35 | 0.9 | 1.5 | 12 | <=0.524< span=""> | <=0.868< span=""> | 175 | 140 | 190 | 150 | ||
1×50 | 1 | 1.5 | 13 | <=0.387< span=""> | <=0.641< span=""> | 210 | 170 | 225 | 180 | ||
1×70 | 1.1 | 1.5 | 14 | <=0.268< span=""> | <=0.443< span=""> | 270 | 215 | 280 | 225 | ||
1×95 | 1.1 | 1.5 | 16 | <=0.193< span=""> | <=0.320< span=""> | 340 | 275 | 335 | 270 | ||
1×120 | 1.2 | 1.5 | 18 | <=0.153< span=""> | <=0.253< span=""> | 400 | 320 | 380 | 305 | ||
1×150 | 1.4 | 2 | 21 | <=0.124< span=""> | <=0.206< span=""> | 460 | 370 | 425 | 340 | ||
1×185 | 1.6 | 2 | 23 | <=0.0991< span=""> | <=0.164< span=""> | 530 | 415 | 480 | 375 | ||
1×240 | 1.7 | 2 | 25 | <=0.0754< span=""> | <=0.125< span=""> | 625 | 490 | 555 | 435 | ||
… | |||||||||||
3×1.5 | 0.7 | 1.5 | 10 | <=12.1< span=""> | <=12.1< span=""> | 25 | 25 | 30 | 30 | ||
3×2.5 | 0.7 | 1.5 | 11 | <=7.41< span=""> | <=12.1< span=""> | 30 | 25 | 35 | 30 | ||
3×4 | 0.7 | 1.5 | 12 | <=4.61< span=""> | <=7.41< span=""> | 40 | 30 | 50 | 40 | ||
… | |||||||||||
Attention: We can provide more info than above data, if needed.The above are just some examples. |
The desprition of 1kv copper xlpe insulated power cable
Characteristics of Cable
1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
2.Installing temperature of cable should not be less than 0°C
3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
4.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.
Type and Specifiction
PVC Insulation Electric Cable
TYPE | Description of Cable
| Main Applications
| |
CU core | AL core | ||
VV | VLV | Copper/Aluminium core,PVC insulated,PVC sheathed power cable | Non-armoured PVC cable are suited for laying indoors,In cable trench,On cable racks and in pipes. Unable bear external pressures and tensions. |
VY | VLY | Copper/Aluminium core,PVC insulated,PE sheathed power cable | |
VV22 | VLV22 | Copper/Aluminium core,PVC insulated,steel tape armored,PVC sheathed power cable | Steel-tape armoured PVC cables are suited for vertical burial.Can bear moderate positive pressures,Unable bear tension forces. |
VV23 | VLV23 | Copper/Aluminium core,PVC insulated,steel tape armored,PE sheathed power cable | |
VV32 | VLV32 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PVC sheathed power cable | Thin steel wire armoured PVC cables are used in case of great difference of levels or vertical installation and Can do vertical burial.Can bear moderate positive pressures and tension forces. |
VV33 | VLV33 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PE sheathed power cable | |
VV42 | VLV42 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PVC sheathed power cable | Thick steel wire armoured PVC cables are suited for vertical installation and can be laid water or sea-bottom.Can bear greater positive pressures and tension forces. |
VV43 | VLV43 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PE sheathed power cable |
XLPE Insulated electric cable
Type | Description | Application | |
Cu Core | Al Core | ||
YJV ZR-YJV | YJLV ZR-YJLV | Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable | Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force. |
YJV22 ZR-YJV22 | YJLV22 ZR-YJLV22 | Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable | Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force. |
YJV32 ZR-YJV32 | YJLV32 ZR-YJLV32 | Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable | Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force. |
YJV42 ZR-YJV42 | YJLV42 ZR-YJLV42 | Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable | Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force. |
- Q: I have lost the power cable which came with my computer's PSU and after looking online for a while the online shops seem to sell the power cables with little information about whether or not they will function with different PSUs so I am guessing it doesn't matter which one I buy.
- minimum watt PSU could desire to be ok given which you do no longer plan on including any peripherals as nicely the basics (a million no longer elementary tension and a million optical tension) and that video card... yet once you have 2 no longer elementary drives or connect a super variety of extra desirable USB units that leech ability out of your device, then you definately will want to have somewhat extra desirable overhead just to be risk-free. 500W or extra useful could desire to be lots. Get one with a minimum of two 12V rails and you may desire to be advantageous.
- Q: I have an electrical source 220 Kv or 380 KV at site X and want to pull cables to site Y to privde electricity for this Y site for general lighting and power sockets.So what is the max distance for the cables i can pull from site X without voltage drop affect the voltage or power at site Y.
- Are you seriously supplying a site with 220-380 Kv to supply general loads? Are you sure that you don't mean 380/220 volts?
- Q: 3 (WDZBN-YJV-4x240 + 1x120) cable how to interpret
- 3 (WDZBN-YJV-4x240 + 1x120) cable is a low smoke halogen-free flame retardant (B grade) XLPE insulated - PE sheathed copper core power cable. The model of the cable is usually composed of eight parts: First, the use of code - not marked as the power cable, K for the control cable, P for the signal cable; so the power cable. Second, the insulation code -Z oil-impregnated paper, X rubber, V polyvinyl chloride, YJ cross-linked polyethylene; so for the cross-linked polyethylene insulation. Third, the conductor material code - not marked as copper, L is aluminum; therefore copper. Four, inner layer code-Q lead package, L aluminum bag, H rubber sleeve, V PVC jacket; so for the PVC jacket. . derived code-D no drip, P dry insulation. Sixth, the outer layer code. . special product code-TH wet tropical, TA dry tropical, ZR- (flame retardant), NH- (fire), WDZ- (low smoke zero halogen, enterprise standards); so low smoke halogen-free flame retardant The . rated voltage - unit KV; general cable are marked, the problem is estimated to write missing 0.6 / . the use of: rated phase voltage of 0.6KV, line voltage of 1KV. In the cable, 4 * 240 + 1 * 120 that there are 4 core 240 square copper wire, a 1-core 120 square copper wire.
- Q: What is the role of the power cable shield?
- General cable shelf life is 10 years, look at the jacket and the insulation with or without cracks, shake the insulation resistance of the general do not breakdown can be used, but the best people to do some pressure test. The withstand voltage test must have been used.
- Q: What are the phone, power, and cable companies in Pomona, Ca?
- Verizon for phone SCE (So cal edison) for power Charter? for cable I think. Get Direct TV it's better Gas is So cal gas.
- Q: I need to know if the power light on the amp will turn on if I don't have the RCA cables hooked up or if you have to have them hooked up just to get power to the amp? I was just wondering because I just hooked up an amp and I can't get the power to come on, and I'm pretty sure the power, ground, and remote wire is hooked up good, it's the RCA cables i'm thinking is messed up, but would the power light come on even if those wasn't hooked up?
- If you have the amp hooked up without rca cables thats where the problems coming from
- Q: Hi. I recently purchased an EVGA Geforce GTX 670 FTW video card that need two 6 pins pci-e power cables. The problem is that the 2 in my pc have L shaped dongles in which one can't connect to the video card due to how it's designed. Is there any way to extend the dongle for reach? Are there any adapters that I can add to it? All knowledge sharing and suggestions will be greatly appreciated. Thanks.
- The specs say PCI express? established laptop is required with one X16 lane photographs slot to be had on the motherboard. So yes, also ensure that your vigor supply is at least four hundred watt, which it should be assuming it's not a relatively ancient machine.
- Q: Electrical equipment installation project "power cable laying" cable cross-sectional area refers to the cable cross-sectional area, or refers to the copper core cross-sectional area, such as 3 × 25mm2 refers to 25mm. 75mm2 or cable cross-sectional area of 490mm2? More
- Calculation method: the amount of engineering calculation formula: L = (pipe length calculation + wire reserved length) × with the number of cross-section wire. Note: plastic pipe should not be flattened, cracks, no debris in the tube, cut the mouth should be flat, the nozzle should be shaved plastic wire pipe connection using glue bonding, plastic pipe bonding must be tightly tight, and in the pipeline plug on the plastic pipe plug, to prevent the paddle, plug tube concrete floor, wall and brick structure of the various switches, socket bottom box , The lamp junction box and the pipe connection must be connected with the wiring, is strictly prohibited plastic pipe directly into the junction box dark in the concrete junction box requirements with wet cement paper or plastic foam filled with internal, not allowed to use The cement paper packs its outside. Embedded in the floor, the shear wall of the plastic pipe, the junction box should be fixed firmly to prevent the shift
- Q: Help in English:do these expressions have exactly the same meaning?
- A cable is usually thicker than a cord. When I hear power cable, I tend to think of industrial machinery.
- Q: Soooooo I don't know much about electronics, but... I'm pretty that my AC power cable for my new receiver was made wrong. You know how it supposed to have a positive and a negative pins? well they are both the same. I know that the wall outlet has the little whole and the bigger one. I've seen some AC power cables that only have the little flat pins so they fit on the wall outlet. My cable has two of the big flat pins... so I can't plug it in the outlet. What do I do? is there like a plug I could buy? I've been using google but I can't find anything...
- The hot side of outlets has a smaller socket dimension, and that's supposed to prevent a plug that has an assigned neutral from being plugged in with the neutral (wider blade) side connected to the hot side. If your plug has two of the wider blades, then that does sound like a manufacturing defect. I'd complain to the manufacturer or vendor. Hopefully the power cord is removable, so you don't have to return the whole unit.
Send your message to us
various types of pvc insulation power cable
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords