1.Features Of Cage-guided Control Valve
Cage-guided Control Valve has a compact valve body, an S-shape flow passage that features low pressure loss and a stabilizer that regulates turbulent flow around the cage , allows a large flow capacity, rangeability and high accuracy flow characteristics, complies with the IEC534-2-1976 standards. High dynamic stability, low noise and little cavitation corrosion. The leakage complies with the ANSI B16.104 standards. The actuator integrated with simplest mechanisms utilizes a compact yet powerful diaphragm actuator loaded with multiple springs or cylinder actuator.
2.Specifications Of Cage-guided Control Valve
Type | Cast globe valve |
Normal size | DN32~600mm |
Pressure rating | ANSI Class 125~2500; PN 1.6~32 MPa * |
Rated CV value | 0.01~820 |
End connections | Flanged:FF、RF、RJ、TG、MFM Welded end: SW(40~50mm);BW(65~250mm) |
Body & Bonnet Material | SCPH2/WCB,SCPH21/WC6,SCS13A/CF8,SCS14A/CF8M,SCS16A/CF3M,Ti and other alloy steels .etc. |
Trim Material | SUS304,SUS304+Stellite,SUS316,SUS316+Stellite,SUS304L,SUS316L,Monel, Hastelloy C .etc. |
Fluid Temperature | -196~+566℃ |
Rangeability | 50∶1 |
Flow characteristics | Linear, EQ% |
Metal seat | ANSI Class IV |
Soft seat | Bubble-tight ANSI Class V,VI |
Actuator | HA Pneumatic Diaphragm type VA/VP Cylinder piston type EIL Electronic type M8 Intelligent type |
3.Body Of Cage-guided Control Valve
Type | Straight-through, single seated, cast globe valve |
Normal size | 32、40、50、65、80、100、125、150、200、250、300、350、400、450mm |
Pressure rating | ANSI Class 125, 150, 300, 600;JIS 10K, 20K, 30K,40K; PN 1.6, 4.0, 6.4 MPa * |
End connections | Flanged:FF、RF、RJ、TG、MFM Welded end: SW(40~50mm);BW(65~450mm) |
Body & Bonnet Material | SCPH2/WCB,SCPH21/WC6,SCS13A/CF8,SCS14A/CF8M,SCS16A/CF3M,Tiand other alloy steels |
Bonnet type | (P) Plain type :-17~+230℃ (EI)Extension Type I:+230~+566℃;-45~-17℃ (EII)Extension Type II:-100~-45℃ (EIII)Extension Type III:-196~-100℃ |
Gland type | Bolted gland |
Packing | Teflon V-ring, Grafoil,etc |
Gasket | Saw-tooth type (Stainless steel)Sprial-wound type(SUS316/316L+PTFE/Grafoil) |
Painting color | Munsell N-6(Epoxy resin group)is standard. In the case of stainless steel body, nopainting is standard. |
4.Images Of Cage-guided Control Valve
5.Applications Of Cage-guided Control Valve
Cage-guided Control Valves are widely applicable for reliable control of high pressure drop, slight cavitation and flashing.
FAQ
Q1:How Can I Get A Sample?
A1:You can get samples by communicate with our export sales.
Q2:How Long Is Delivery?
A2:Delivery time will be30-45days according to order quantity.
Q3:What Is The MOQ?
A3:MOQ depends on different items.
Q4:What Is Our Normal Payments Terms?
A4:Our normal payment terms now is: T/T, L/C or western union,paypal
- Q:I recently had an echo and they said their was a slight tricuspid valve leak but it was 19 and anything less than 20 is considered normal. I have no clue what that means. Does any one have and clue on what scale she was talking about. Also she stated that the machine are so sensitive these days that the majority of people are found to have some sort of leak. Is this the case??????
- The tricuspid valve is a valve in your heart that, like any other valve, makes the blood flow in only one direction. When your heart pumps blood into your body, this valve is normally closed so the heart only pumps it in your arteries, and not back in your veins whence it came. When this valve doesn't close shut completely, a little quantity of blood leaks through the little opening there. You can see this with an echocardiography which you said you had done. Yes, the value of 19 is really low, and the fact that the limit to normality is 20, so you're close to it, doesn't mean that you're almost sick. Keep in mind that these limits that doctors have are some guidelines, and they all have a safe zone. Plus, this is not the kind of lesion that evolves, it doesn't mean that as the years go by the little space in your valve will get bigger and bigger - nothing of that sort. It is probably a thing that you had since forever, and you will have it the same your whole life with no problems at all. In the end, let me say that if you are brave enough to go to a doctor (many people aren't, and that really sucks), you should be brave enough to ask him/her what they mean when they say certain stuff, without worrying that your question might be stupid or already answered. You didn't go to med school, and it is the doctor's duty to explain to you what is happening in your body just as it is to diagnose and treat you. Best of luck!
- Q:I just dropped my 3rd valve slide from my trumpet on the ground. It fell with the curved end first. I can't see any dents and it doesn't look bent, but I oiled it and everything and it's really hard to move. Could it be bent? How can I fix it?
- Be sure that it is aligned correctly when you place it back in the valve casing. When you are putting it back in, it has to turn until you hear a click, indicating that the valve guide has fallen in the right space. This aligns the valve with all the ports. (The valve guide is a small plastic piece located under the valve spring. This valve guide must snap into a little notch inside the casing. When it does, the valve will be perfectly aligned. You will know when the valve guide is in the right place because you will feel and hear a click and the valve will not rotate any longer.) After thorough cleaning, oiling, and correct valve placement, if you still notice it sticking, take it to a repair shop to have it chemically cleaned. They are typically very good and will ensure your trumpet is in proper playing condition.
- Q:There has been brake fluid leaking below where the Master Cylinder was and pinpointed that the leak was at the base where the steel lines and proportional valve intersect(kinda sprays out out like if a seal is bad or someone didn't tighten enough). Any way to fix this or replace? Vehicle is a 1988 Plymouth Reliant (2.2 liter) Auto, no ABS.
- If you are not familar with brakes I wouldn't suggest tackling this job yourself. You will need to take the line off in question to condemn either the prop valve or the line. I have never in my life seen the line itself leak but I guess it's possible. The valve is a dealer item only, whatever you do, dont buy it from a junk yard. After replacing the valve, if that is what the problem is, most likely you will need to get a brake power bleeder to get all the air out of the system. I would estimate through a shop and the typical mark up on the part, shouldn't be more than 200-225 parts and labor including the brake flush, good luck.
- Q:Can a leaking car tyre valve be repaired/ replaced, or is it more viable to get a new tyre fitted with a new valve?
- you can take the old valve out and put a new 1 in. auto zone sells new valves.
- Q:I'm taking a pipe fitting class and I can not find witch valve had the most restriction.
- A globe valve has a lot of resistance (restriction) even when it is open A metering valve has adjustable restriction but i am thinking that that is not what you are asking.... A gate valve or ball valve has less resistance (a ball valve has almost none).
- Q:I'm installing a shut off valve under my sink. can you tell me all the materials that i need to install it by myself because to hire some body else is very expensive where i live. i need to change the old ones because they are leaking very bad when i want to use the sink.thanks a lot
- its called 'an angle-stop' and if you have copper, its sweated on or compression fit. if its compression, get a crescent wrench and take it off at both pipes and take to store and replace same ones, but better quality. don't forget to shut off the water to the house outside! if its sweated on, you need to have someone that knows how to copper weld to do it for you. if its galvanized pipe, unscrew it like 1st and proceed with another like item or switch to copper with a dialectic fitting between both.
- Q:Does a diverter valve even make a sound at all?
- No. A diverter will typically be installed before any catalytic converter or muffler to allow you to have a free straight flowing exhaust by dumping the exhausted there. it has two out puts and one input. one out goes to stock exhaust one to open exhaust. Noise on demand really. Blow off valves for are for Turbo charged cars and make a whistling noise when they release air pressure when u let off the gass.
- Q:Is there a product that can fit over a foot valve to give it further protection in muddy water? I am looking for something for forest firefighting in mind. Something like a screen box something else that can give it further protection. It would be nice if it was small, and compact. Pictures would definitely be an asset. Thanks to everyone that answers. Greatly appreciated.
- most foot valves i have bought come with a strainer attached perhaps you should look for that type. if your valve has a strainer you may consider making a further coarse strainer out of a ball of chicken wire and place this over the foot valve assembly(thats what i do for the cold water supply to my house) don't compress the chicken wire very small as it will block up i tie the wire filter on with galvanized wire then i can easily replace it if necessary ps i tried stainless steel pot scourers but they were to fine and blocked easily
- Q:the ac replacement valve seems to be leaking i was wondering what is the average cost of having it replaced..
- The ac replacement valve? Well, what you can do is to get the new ac to replace the old ac.
- Q:-air pressure of 40 psi only -run on 12v or 250 vac-no need for half open or any of the options i just want it on or off-it will be for a costum use so i dont need any special designs for it any thing will work -it also can be change from gas to water if
- Cheap Solenoid Valve
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Cage-guided Control Valve Made In China Best Price
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 pc
- Supply Capability:
- 1000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords