50kva - 1500kva Electric Cummins Diesel Generator 6BT5.9G1
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
50kva to 1500kva Electric Generator For Sale
1. Dry type air filter, fuel filter, oil filter
2. 10-hour operation base tank
3. 24V DC start motor and storage battery
50kva - 1500kva Electric Cummins Diesel Generator 6BT5.9G1
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRC30 | 20 | 25 | 24 | 30 | 4B3.9-G | ≤229 | 4 | 3.9 | 102*120 |
GNRC35 | 24 | 30 | 28 | 35 | 4BT3.9-G | ≤214 | 4 | 3.9 | 102*120 |
GNRC56 | 40 | 50 | 45 | 56 | 4BTA3.9-G | ≤215 | 4 | 3.92 | 102*120 |
GNRC63 | 45 | 56 | 50 | 63 | 4BTA3.9-G | ≤215 | 4 | 3.92 | 102*120 |
GNRC70 | 50 | 63 | 56 | 70 | 6BT5.9G1 | ≤215 | 6 | 5.88 | 102*120 |
GNRC106 | 78 | 98 | 85 | 106 | 6BT5.9G | ≤215 | 6 | 5.88 | 102*120 |
GNRC125 | 90 | 113 | 100 | 125 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC150 | 104 | 130 | 120 | 150 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC165 | 120 | 150 | 132 | 165 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC200 | 140 | 175 | 160 | 200 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC225 | 160 | 200 | 180 | 225 | 6CTAA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC275 | 200 | 250 | 220 | 275 | 6LTAA8.9-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC313 | 220 | 275 | 250 | 313 | NTA855-G1A | ≤206 | 6 | 14 | 140*152 |
GNRC350 | 250 | 313 | 275 | 350 | NTA855-G2 | ≤207 | 6 | 14 | 140*152 |
GNRC400 | 280 | 350 | 310 | 400 | NTA855-G4 | ≤208 | 6 | 14 | 140*152 |
GNRC413 | 300 | 375 | 330 | 413 | NTAA855-G7 | ≤206 | 6 | 14 | 140*152 |
GNRC450 | 320 | 400 | 360 | 450 | NTAA855-G7A | ≤206 | 6 | 14 | 140*152 |
GNRC500 | 360 | 450 | 400 | 500 | KTA19-G3 | ≤203 | 6 | 18.9 | 159*159 |
GNRC550 | 400 | 500 | 440 | 550 | KTA19-G4 | ≤203 | 6 | 18.9 | 159*159 |
GNRC605 | 440 | 550 | 484 | 605 | KTAA19-G6 | ≤204 | 6 | 18.9 | 159*159 |
GNRC625 | 450 | 563 | 500 | 625 | KTAA19-G7 | ≤204 | 6 | 18.9 | 159*159 |
GNRC700 | 500 | 625 | 560 | 700 | KTA38-G | ≤206 | 12 | 37.8 | 159*159 |
GNRC712 | 520 | 650 | 570 | 712 | QSK19-G3 | ≤206 | 6 | 19 | 159*159 |
GNRC800 | 580 | 720 | 640 | 800 | KTA38-GA | ≤209 | 12 | 37.8 | 159*159 |
GNRC825 | 600 | 750 | 660 | 825 | KTA38-G2 | ≤210 | 12 | 37.8 | 159*159 |
GNRC888 | 640 | 800 | 710 | 888 | KTA38-G2B | ≤210 | 12 | 37.8 | 159*159 |
GNRC975 | 720 | 900 | 780 | 975 | KTA38-G2A | ≤210 | 12 | 37.8 | 159*159 |
GNRC1075 | 800 | 1000 | 860 | 1075 | KTA38-G5 | ≤202 | 12 | 37.8 | 159*159 |
GNRC1375 | 1000 | 1250 | 1100 | 1375 | KTA50-G3 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1375 | 1100 | 1375 | 1310 | 1650 | KTA50-G8 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1650 | 1200 | 1500 | 1340 | 1675 | KTA50-GS8 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1675 | 1350 | 1688 | 1500 | 1875 | QSK60-G3 | ≤215 | 16 | 60 | 159*159 |
GNRC1875 | 1500 | 1875 | 1650 | 2063 | QSK60-G3 | ≤215 | 16 | 60 | 159*190 |
GNRC2063 | 1600 | 2000 | 1800 | 2250 | QSK60-G4 | ≤215 | 16 | 60 | 159*190 |
Genset Features:
1. Genuine Commins industrial diesel engine
2. Radiator 40°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9. Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards
15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Engine Features:
1. Genuine Cummins industrial diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
Alternator Features:
1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts
7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528
9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel
Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.
Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown
Super Soundproof/Silent Box:
1. Excellent ventilation
2. Oil tank mounted on base frame for 12 Hours working
3. Highly Corrosion Resistant construction
4. Excellent Access for Maintenance
5. Security and Safety
6. 1m<80DBA / 7m<70DBA
- Q: What is the difference between a step motor and an ordinary motor
- Stepper motor and the general difference is mainly lies in the form of the pulse drive (send a pulse control system, can give in a rotary Angle of motor), because of the characteristics of step motor can be combined with modern digital control technology (particularly suitable for mechanical and electrical integration products). However, it is inferior to the traditional closed-loop dc servo motor in the accuracy, speed range and low speed performance of the step motor. It is possible to use stepping motor in an environment where precision is not particularly high, and the step motor can be characterized by simple structure, high reliability and low cost. When used properly, it can even be compared to the performance of dc servo motors.
- Q: How do you differentiate the converter motor from the general motors?
- Variable frequency motor and the common one of the biggest difference is the fan cooling way, general motors was the cold, the fan on the motor shaft, changes with the rotational speed of the motor, so the ordinary motor at low frequency heat dissipation is not ideal. Frequency conversion motor cooling fan is behind the motor equipped with a cooling fan, need an external power, the fan will not be affected by the speed of the motor, is a strong refrigeration.
- Q: Is the servo motor to be used as a common motor?
- Due to the overload ability of servo motor, the rated torque of servo motor can be determined by reference to 1/3 of the output torque of the motor.
- Q: What is the difference between a single phase motor and a two-phase machine?
- Motor has single-phase ac motor and three-phase motor. I haven't heard of a two-phase machine. Are you asking for a positive reverse motor? Three phases are phase modulation. Any two phases are exchanged. C, R, S.
- Q: Can variable frequency control motor be used as a general motor?
- The variable frequency speed regulating motor is a three-phase asynchronous motor with a normal squirrel-cage, and a cooling fan, In other words, the variable speed motor is more strict than the general motor, so there is no problem with the general motors. Variable frequency control motor is a general term for the motor that is driven by a frequency converter. Actually designed for frequency converter motor for frequency conversion motor, the motor can be realized by the driving of the frequency converter different rotational speed and torque, to adapt to the demand of load change. Frequency conversion motor by traditional squirrel-cage motor development, changed the traditional motor fan to fan, independence and improve the performance of the insulation of the motor winding. In the case of low power and frequency, the ordinary squirrel cage motor can be used instead of the normal working frequency.
- Q: How does the heat of dc motor control
- There are several reasons for the fever of dc motors: The current of the actuator is larger than that of the motor The speed of the motor is too fast The inertia of the motor and the torque of the positioning torque are high, so even the medium speed can be hot, but it does not affect the life of the motor. Motor demagnetization points in 130-200 ℃, so in 70-90 ℃ belongs to the normal phenomenon, as long as less than 130 ℃, generally do not have what problem, if you really feel overheated, the drive current set the speed of the motor about 70% of the rated current or reduce one
- Q: The problem of speed regulating motor and general motors
- Of course must be better than the general motor. On the electromagnetic, due to the variable frequency power supply with accompanying wave current, frequency conversion motor by the special design, can reduce the resulting electromagnetic loss. In addition, the speed control system for motor has higher sensitivity and should minimize its moment of inertia. Speed regulating motor in these areas have special design. Of course also can be used as ordinary motor speed regulating motor, but it won't pay!
- Q: What is the difference between the riot motor and the ordinary motor? How does it work differently from ordinary motors? Is it possible to be overloaded with ordinary motors? Please help me, thank you.
- The generator is the same as the electric motor, which runs on the motor. The drive is driven by the rotor, and the magnetic field cutting stator winding inducs the electromotive force to become a generator.
- Q: Can ordinary motors use a frequency converter?
- Of course, there is a problem to note that the low frequency runs solve the motor fan heat
- Q: What is the difference between the decelerating step motor and the normal step motor?
- The step motor can be divided into reactive step motor, permanent magnet step motor and hybrid step motor. And what you're saying is that the decelerating step motor is just a decelerating function of the step motor. By controlling the pulse frequency, you can change the speed of the step motor. Stepper motor positioning control is the acceleration and deceleration control stepping motor to drag a given load, through acceleration, constant, high speed and deceleration process, quickly from one location to move to another location.
Send your message to us
50kva - 1500kva Electric Cummins Diesel Generator 6BT5.9G1
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords