• 11KV 3c 150mm2 185mm2 300mm2 STA armoured XLPE power cable System 1
  • 11KV 3c 150mm2 185mm2 300mm2 STA armoured XLPE power cable System 2
  • 11KV 3c 150mm2 185mm2 300mm2 STA armoured XLPE power cable System 3
  • 11KV 3c 150mm2 185mm2 300mm2 STA armoured XLPE power cable System 4
  • 11KV 3c 150mm2 185mm2 300mm2 STA armoured XLPE power cable System 5
11KV 3c 150mm2 185mm2 300mm2 STA armoured XLPE power cable

11KV 3c 150mm2 185mm2 300mm2 STA armoured XLPE power cable

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
200 m
Supply Capability:
20000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

11KV 3c 150mm2 185mm2 300mm2 STA armoured XLPE power cable
1. Factory direct sale
2. Superior performance
3. Fast delivery

11KV 3c 150mm2 185mm2 300mm2 STA armoured XLPE power cable
1. Factory direct sale
2. Superior performance
3. Fast delivery

 

Description

  

1. Information

 

a, Number of cores: 1,  2,  3,   3+1,   3+2,   4,    4+1,    5.

 

b, Construction:

 

Conductor: Solid or stranded copper/aluminum
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
Filler: Polypropylene filament with lapped binding tape
Binder: Binding tape
Inner sheath: Polyvinyl chloride (PVC)
Amour: Galvanized steel wire armored(SWA) or steel tape armored(STA)
Sheath: Polyvinyl chloride (PVC)

 

c, Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

 

d, Features

 

XLPE  insulated power cable do not has excellent electric, mechanical properties,but also has powerful resistance against chemical corrosion,heat resistance and enviromental stress resistance. Its structure is simple. The long period operating temperature is +90 °C. It is conveninet to use and can be laid with no restriction of different level.

 

XLPE insulated steel wire armoured power cable: XLPE/PVC insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE cable has high electric strength, mechanical strength, high-ageing resisting, environmetal stress resisting antichemical corrossion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.

Various of flame-retardant and non-flame retardant XLPE cable can be manufactured with three technology(peroxide, silane and irradiation crosslinking). The flame-retardant cable covers all kinds of low-smoke low-halogen low-smoke halogen free, and non-smoke nonhalogented and three classes of
A, B, C.

 

2. Standard:

 

IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer's request.

 

3. The Rated Voltage(kv):

 

1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35

 

4. Application:

 

1)These cables are most suitable for direct burial or for installation on trays or ducts,  Where there is
a risk of mechanical damage, armoured cables should be used.

 

2) For laying in ground along route with large difference of level able to bear external mechanical forces.

 

5. Model and Name

 

China Type

Description

Application

Cu

Al

YJV

YJLV

XLPE insulation PVC sheath power cable (Cu/XLPE/PVC)

To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside 

YJY

YJLY

XLPE insulation PE sheath power cable (Cu/XLPE/PE)

YJV22

YJLV22

 XLPE insulation, steel tape armor,  PVC sheath power cable

(Cu/XLPE/PVC/STA/PVC)

To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force.

YJV23

YJLV23

XLPE insulation, steel tape armor,  PE sheath power cable

(Cu/XLPE/PVC/STA/PE)

YJV62

YJLV62

XLPE insulation,  no  magnetism steel tape armor,  PE sheath power cable

YJV32

YJLV32

XLPE insulation, thin steel-wire  armor,  PVC sheath power cable

(Cu/XLPE/PVC/SWA/PVC)

Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint

.

YJV72

YJLV72

XLPE insulation, have no the magnetism thick steel-wire  armor,  PVC sheath power cable

YJV42

YJLV42

XLPE insulation, thick steel-wire  armor,  PVC sheath power cable

Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.

 

6. Specification

 

RateVoltage(kv)SectionalArea(mm 2 )No.of Core

 

1st class

0.6/1

1.8/3

3.6/6

6/10

8.7/15

12/20

18/30

21/35

2nd class

1/1

3/3

6/6

8.7/10

12/15

18/20

-

26/35

1 Core

1.5-800

25-800

25-1200

25-1200

35-1200

50-1200

50-1200

50-1200

2 Core

1.5-185

25-185

3 Core

1.5-400

25-400

25-400

25-400

35-400

50-400

50-400

50-400

4 Core

2.5-400

25-400

5 Core

2.5-400

25-400

 

ZR: Means Flame retardent

 

Type

Nominal  cross-sectional area

Single-core

2-core

3-core

4-core

5-core

YJV

ZR-YJV

YJLV

ZR-YJLV

1.5-800

1.5-300

1.5-300

1.5-300

1.5-300

YJV22

ZR-YJV22

YJLV22

ZR-YJLV22

10-800

4-300

4-300

4-300

4-300

YJV32

ZR-YJV32

YJLV32

ZR-YJLV32

10-800

4-300

4-300

4-300

4-300

Q: I was just wondering because I need a new power supply for my computer. It is an Acer Aspire AM3910-U4012. Is the power cable that connects to the motherboard the only power cable I need to replace or will I need to replace all the cables in my computer for it to work properly?
It will come with an all new set of cables! You should continue to use the cables that you have installed already, and save the new ones for later. You never know when you'll need to replace one, or when a friend might need one from you.
Q: I have been doing research online and have found replacement power cables from Kimber, Nordost, PS Audio, Cardas, Monster and Audioquest. While Kimber did win an award in Audiophile magazine, the write up for PS Audio's SC statement cable appears to be very good as well. Nordost makes a great product too, but have read some complaints that it actually cheats the bass. So I am basically looking to see if anyone owns any of the replacement cables from these companies or what they could recommend as a good replacement power cord.
This question does not make sense. Power cord for what equipment? Most audio and video equipment comes with the power cord attached or uses a standard 3 prong 110v power cable that you see on computers. A power cord should not affect quality. To improve quality, you should have a power conditioner or line conditioner to clean the power going to your equipment. Please elaborate on what you are trying to do.
Q: How can we make out the physical size of a power cable if the cable is said to be 4 core, 150 sq.mm ??? How will we measure the diameter of this cable ???? please suggest......
A 4core (electrical) cable of that strength is usually built up from quarter circle shaped sectional wires. (Think of a pizza cut into four even pieces.) So, calculate the outside diameter from this point and add 4 times the insulator thickness. Example: 400V 4core cable has very likely 1mm insulator thickness. 150mm? * 4 cores is 600mm? total. By A=PI*d'*d'/4, d' being the diameter without insulator, would be d'=2*sqrt(A/PI)=600mm?/3.1415...=2*sqrt(...? Now, as said above, add the 4 insulator layers, and then you would be at approx. 31.7mm outside diameter.
Q: So I'm trying to add a sata hard drive from an older computer in my new one, but I encountered a problem. I have the cable the connects to the motherboard and the hard drive, but when looking at the power connectors for the hard drives, there is only one and it is connected to the main hard drive. Am I missing something that is slapping me in the face here, or is this a design flaw? there are 6 hard drive holders sooooo, it seems that there should be 6 power cords inside, but no. Only one. What do I do?
are you sure there's not 1 power cord with six plugs on it? often the power cables will have connectors all the way down them.
Q: some one told me that cisco get this router without AC power it get the power from the network cable?
You need to make sure your Switch supports POE (power over Ethernet).
Q: The question above relates with the Transpose Line.One of the subtopics under Transmission Line Parameters in Power System.
If the adjacent line induces current in a nearby cable that would be a problem. Transposing results in one section having an induced current with a certain phase but the next section (after the transposition) has an induced current with the opposite phase. Over the length off the cable, the opposing induced currents will cancel each other out.
Q: what does it mean by 4 core cable, 35 mm. can it be used for DC and AC as well. can it be used for a 3 phase AC. what are its advantages and disadvantages? is one core means one phase? can we use 2 core cable for 3 phase AC? am really confused please explain.
A 4 core cable has 4 conductors in an overall sheath. The 35 mm indicates the area of each conductor's copper is 35 square mm. You can use the 4 core cable for 3-phase power (3 wires with a spare or ground). You cant use a 2-core cable for three phase service, unless you are using three 2-core cables with the 2 wires connected in parallel to provide one of the phases. It can be used for AC or DC. TexMav
Q: Cable YJV-1KV-5 * 10 pipe laying, including cable head system with what fixed amount?
It is generally not required to do so because the battery on the computer side of the charge side of the use of all right
Q: i am going to establish a new power cable manufacturing business. i want to ask you what should i name to my business or what brand name should i adopt that is appopriate.
follow the suggestions. Good Luck
Q: This morning my cable modem seems to be malfunctioning...it's a Motorola SURFboard and it has a column of lights on the front (labeled Power, Receive, Send, Online, Activity, and Standby accordingly) that are all supposed to be lit up (except Standby) when I'm online. Well some of the lights keep going on and off--namely the quot;receivequot;, quot;sendquot;, and quot;onlinelights. In addition, my internet is operating very slowly and/or not at all; sometimes I get the quot;page cannot be displayedmessage when I try to navigate to another page; sometimes it goes thru ok but loads at snail's pace. Does this mean there's a problem with my computer or modem, or is it just that the internet is down in my area?
Ok, the send and recieve lights are supposed to flash, this is good. the connected light should be steady and the connected to pc light can flash if it wants the slow connection could be many things call your cable computer and ask them what to do if there's nothing wrong with your cable settings, run a virus check, spyware check, and adware check. possibly restore your entire pc to factory condition.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches