• Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable H05Z-K System 1
  • Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable H05Z-K System 2
  • Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable H05Z-K System 3
Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable H05Z-K

Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable H05Z-K

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
30000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable

Production Introduction for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:


Voltage Rate: 300/500V, 450/750V

Cores: 1~7 cores

Range of Nominal cross section: 0.50 mm2 ~ 120 mm2

Conductor: Class 5 fine annealed copper wires or tinned copper wires

Constructions:Insulation: XLPE or LSZH compound

           Sheath: LSZH compound

Core color: Brown, Grey, Black, Blue, Green/Yellow or others on request

Packing: 100 meter/roll for small size, wooden drum for big size, or as per requirement

Max. Operating Temperature: 90 ℃ , can be 105 ℃ ,110 ℃ and 125 ℃ as per

Application for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable :

The wires are flexible conductors used for the stranding of electric switchboards or lighting

systems, etc, they are particularly recommended where fire risks are important, and for public

installations or closed areas, also fit sensible buildings such as datas and electronic rooms.

 

Production Standard for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:

IEC 60227, BS6500, VDE0281, GB/T 5023, JB/T8734

 

The  Feature for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:

The cable can be of flame retardance, fire resistance and other property

 

Packing photo for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:



Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable H05Z-K

Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable H05Z-K

FAQ For Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable :

 

Q1:What is the Production Capacity for your factory?

About100 kilometer every day

 

Q2: What is the Minimum Order Quantity For Single Core PVC Insulated Cable 450 /750 V?

MOQ: 10000 meters for small size, 5000 meters for middle size, 1000 meters for big size

 

Q3:What is the delivery time for these cables?

10~15 working days

 

Q4: What standards is the product complying with?

    We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.


 

Q4: What standards is the product complying with?

    We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.



Q: What is the difference between an ordinary power cable for a dedicated cable?
Inverter special cable General power cable difference shielding requirements higher, the number of cores is generally 3 +. three lines of the ground line of three symmetrical and phase line intersection. Variable-frequency (VFD) is the application of frequency conversion technology and microelectronics technology, by changing the motor operating frequency mode to control the AC motor power control equipment. The inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on. The inverter will adjust the voltage and frequency of the output power by the breaking of the internal IGBT, according to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition, the inverter has a lot of protection , Such as overcurrent, overvoltage, overload protection and so on. With the continuous improvement of industrial automation, the inverter has also been a very wide range of applications.
Q: computer MB does not contain a power supply connector for the SATA power cable leading to the SATA HD, is this the norm? the cable connector is 5 prong female, there is no 5 prong male connector on the MB or the PSU. any suggestions?
ur mainboard is only ide compatible then, u can add a sata pci card tho so as to add sata drives !!! :)
Q: I recently replaced my 300W Bestec power supply with a 600W corsair power supply. the 600W electric cable (the one that goes to the wall outlet) is too short, can i use the power cable of the 300W power supply ?
Yea, u can use it. Because it don't depend on your PSU. It depends on your electric connection.
Q: Why is my 2 Gage power cable from the battery to my amp is to hot and makes a big spark and burns the wire when you meet one end to the other end?
Too hot means the current is very high. Probably in excess of 200 amps. I suspect there is a short in the amp, specially if you tried to connect it hot and drew a spark. That will kill a lot of electronics. .
Q: Would a maxtor 320GB external hard drive work without a power cable if I connect it to the USB port?
you could make it work if you are planning to make a usb cable for power and another one for the receiving and sending of data. but if you are meaning to just plug in the usb cable from the hard drive to a port then no you can't a usb is ussually 5V and i don't think that's enough to power up a hard drive. just buy a power cable they aren't that expensive. if you have enough money to buy the external hard drive you wouldn't mind spending 5-10 dollars for a power connector.
Q: I managed to break off the tip of my laptop power cable to the point that I need it replaced. I can't pay with cash on OKorder and don't own a credit card. Anyone know an electronics store where I could find another? Thank you.
Eee mini laptops use something referred to as an SSD complicated force or a stable State force. those are drives that have no shifting factors in them. THey perform very such as a USB flash force with in uncomplicated terms circuits and chips on them, no automobiles, no platters, no needles like complicated Drives. they are very rapid and extremely cool to assert the least :) With admire to those with cameras they are the fashions in the 900 and 1000 sequence that characteristic cameras. The seven hundred sequence ones have an non-compulsory digital camera on the 701 sort. have exciting at the same time with your new pc mini :) they are exciting Oh and additionally look at IBM, they make mini laptops too and additionally the recent MacBook Air is a mini pc, it extremely is particularly easy, slender and probable the best one :)
Q: are there power cables or batteries? Thanks
I bought the Rocketfish wireless rear speaker kit at BB for $99.99 and I love it. The unit plugs into the back wall behind my couch and you run the wires from it, not the reciever. I'm sure having it wired is the best way, but I have no complaints about my set up. It sounds great.
Q: Wire and cable should be used in parallel when the attention
Have to fight trumpet, mainly to protect the cable jacket is not scratched
Q: Copper core power cable laying (cable section YJV4 * 35 + 1 * 16mm2) Will the dawn of the software in how the amount of superposition? The Please master instructions, the problem added: YJV4 * 35 + 1 * 16mm2 is not the 4 * 35 + 1 * 16 = 156mm2 copper core power cable laying (cable section 156mm2) to count, more
Is the aluminum core armored cable for outdoor high pressure conforming to the specification
Q: why power cables are to be earthed at both ends?
Its called the M.E.N. system. It stands for Multiple Earth Neutral. The neutral of an appliance acts as a return, held at a low potential by earthing at each house, using rods into the ground, transformers in the street with earths, and earth mats where required when soils are not conductive. When a fault occurs to earth the low earthing point causes the fuse / breaker to trip. GL

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products