• XLPE insulated copper conductor power cable System 1
  • XLPE insulated copper conductor power cable System 2
  • XLPE insulated copper conductor power cable System 3
  • XLPE insulated copper conductor power cable System 4
  • XLPE insulated copper conductor power cable System 5
  • XLPE insulated copper conductor power cable System 6
XLPE insulated copper conductor power cable

XLPE insulated copper conductor power cable

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
1000000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 XLPE insulated copper conductor power cable

1.Factory price
2.international standards
3.fast delievery                 

Executive standard

International: IEC 60502-2, IEC 60228, IEC 60840, IEC62067

Chinese: GB/T 12706.1~12706.3-2008

Other standards such as BS,DIN and ICEA upon request

 

Applications

For laying indoors , in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force .

The product is suitable for use in power transmission and distribution lines with ra

power frequency voltage 3.6/6kv~26/35kv.

Operation characteristics

  1. Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv

  2. Max. admissible operating temperature of the conductor:90

  3. Max. short-circurt temperature of conductor shall not exceed 250.
    (5s maximum duration)

  4. The ambient temperature under installation should not below 0

  5. The bending radius of a single-core cable should not less than 20 times of the cable diameter.
    The bending radius of a three-core cable should not less than 15 times of the cable diameter.

Type of cable

Type

Designation

Application

YJV

Copper conductor, XLPE insulated and PVC sheathed power cable

For laying indoors , in tunnel or cable trench, unable to bear external mechanical forces. Single-core cable in magnetic duct is not permissible

YJLY

Aluminum conductor, XLPE insulated and PVC sheathed power cable

YJY

Copper conductor ,XLPE insulated and PE sheathed power cable

YJLY

Aluminum conductor ,XLPE insulated and PE sheathed power cable

YJV22

Copper conductor ,XLPE insulated, steel tape armoured and PVC sheathed power cable

For laying indoors , in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force

YJLV22

Aluminum conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable

YJV23

Copper conductor ,XLPE insulated ,steel tape armoured and PE sheathed power cable

YJLV23

Aluminum conductor ,XLPE insulated ,steel tape armoured and PE sheathed power cable

YJV32

Copper conductor, XLPE insulated, steel wire armoured and PVC sheathed power cable

For laying indoors , in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force .

YJLV32

Aluminum conductor ,XLPE insulated, steel wire armoured and PVC sheathed power cable

YJV33

Copper conductor ,XLPE insulated ,steel wire armoured and PE sheathed power cable

YJLV33

Aluminum conductor ,XLPE insulated ,steel wire armoured and PE sheathed power cable

Production range of cable

Type

Nomber of cores

Rated Voltage kV

3.6/6

6/6 6/10

8.7/10 8.7/15

12/20

18/20 18/30

21/35

26/35

Nominal cross-section of conductlr mm2

YJV
YJLV
YJY
YJLY

1

25-800

25-800

25-800

35-800

50-630

50-630

50-630

3

25-630

25-630

25-500

35-500

50-400

50-400

50-400

YJV22
YJLV22
YJY23
YJLY23

1

25-800

25-800

25-800

35-800

50-630

50-630

50-630

3

25-630

25-630

25-500

35-500

50-400

50-400

50-400

3

25-630

25-630

25-400

35-400

50-240

50-185

50-150

 

Workshop

 

Package & Shipping

 

 

 

Q: Alright, im most likely moving to Germany in December, and im bringing my PS3 over with me. That I bought here in the US.. Is it possible for me to buy the power cable for a PS3 that works in Germany and plug it into my current PS3, or will it short it out?
It won't short out, cause it will only take certain power
Q: I am trying to hook up a LCD display (CPU Temp, USB's in use, Memory Temp/usage, etc) and It came with a 5pin DIN connector for what I assume is the power. I am not sure what I need to do to connect it to the PSU. Any help or ideas?
I think this device should have a power connector as well as a sensor cable (USB in use should have a connector running on to your motherboard.) can you provide me the make/mode number of the equipment. Also provide me with a link so that i could see the connectors and wires and the device. Else take a pic, upload it some image hosting site and provide with a link. (you can edit your question or add additional info and provide a link. Replace the http with hxxp, if the link is getting blocked)
Q: I need to run power cables from 4 fans on my stacker 830 around the edges of the case and into the power supply for cable management purposes. The fans I currently have, have power cables that are around only 10 inches long. Any ideas?
Can you solder? If so, just clip the wires then splice on extensions. Add heat-shrink material, solder connections, shrink the material and you're good to go.
Q: I'm gonna build a pc, the graphics card is an XFX Radeon 6970 and the power supply is a cooler master 750w. Im new to this and I dont want to buy a cable online and have it be the wrong one
Well, you really shouldn't build a PC if you don't know what you are doing.
Q: The hard drive is: Western Digital Caviar SE WD3200AAJS 320GB 7200 RPM, I'm getting from Newegg OEM. I know that OEM's don't come with a SATA cable which is fine but where can I find a compatible power cable? If it comes with one already please let me know. Thank you in advance.
An internal drive would be powered by your power supply. If you don't have any additional SATA power cords in your PC, I believe you can by a 4 prong to SATA converter. Otherwise you may have to look at getting a new power supply for your PC that has more SATA power adapters
Q: I am getting a new 160 amp high output alternator for my 2005 Mazda 3 2.3L. I am running a 1000w amp with two subs. I have the stock alternator in it right now. There are two power cable kits available for me to get. One that has 4 gauge wire with a 100 amp fuse and the other, 1 gauge with 150 amp fuse. Which kit should I get? Can I just add 4 gauge wire along with my stock wire instead of the 1 gauge kit? What are the fuses for and which one would work better? I know nothing about this. Thanks.
I would go with the 1 ga wire. The fuse keeps the wire from setting your car on fire. The size of the alternator does not matter. The battery should supply 700 amps or so.
Q: Hi, I have a router connected to the internet, but one of the computer is 80 feets away from the router and it can not get 100MBps. I have force the computer to use 10MBps. Could someone please let me know what will impact the speed of cat5 cabling?
Ok, please note the following: MB/s = MegaBYTES per second Mb/s = MegaBITS per second 10MB/s = 100Mb/s (roughly) Your router and NIC card is 100Mb/s (unless they are both Gigabit - Gb/s which will give you roughly 100MB/s in speed assuming both the NIC and router can support that speed.) I hope this answers your question.
Q: im curious what a good rule of thumb would be for determining how strong a fuse to put in line to the amp. im getting a 2300 watt amp but dont know how many amps of fusing it uses. so i dont know its power draw. any help would be great
current(A)=power(W) / voltage(V) go with Jeffs answer so you can blow them all-idiot do the math! 2300/12=191A! How hard is that!
Q: So I use my laptop with power and only put in the battery when I take it around. So I sat my computer down and it abruptly just shut down. I powered it on and I set it down again and the same thing happened. The third time it went all the way to the desk top. I touched and moved around the power cable connected to it shut down. WTF
sensitive power supply connection i guess
Q: Sometimes I have to jiggle the chord or plug it in the right position to get the laptop to be charged. At first, I thought it was the power cable, but after buying a new one, I still have the same problem. Any suggestions as to what causes this and how to fix it?
The power jack internal to the laptop, is probably faulty, not the cable. If your laptop is under warranty I would look at filing a claim to get it fixed.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords