XLPE insulated copper conductor power cable
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 1000000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
XLPE insulated copper conductor power cable
1.Factory price
2.international standards
3.fast delievery
Executive standard
International: IEC 60502-2, IEC 60228, IEC 60840, IEC62067
Chinese: GB/T 12706.1~12706.3-2008
Other standards such as BS,DIN and ICEA upon request
Applications
For laying indoors , in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force .
The product is suitable for use in power transmission and distribution lines with ra
power frequency voltage 3.6/6kv~26/35kv.
Operation characteristics
Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv
Max. admissible operating temperature of the conductor:90℃
Max. short-circurt temperature of conductor shall not exceed 250℃.
(5s maximum duration)The ambient temperature under installation should not below 0℃
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a three-core cable should not less than 15 times of the cable diameter.
Type of cable
Type | Designation | Application |
YJV | Copper conductor, XLPE insulated and PVC sheathed power cable | For laying indoors , in tunnel or cable trench, unable to bear external mechanical forces. Single-core cable in magnetic duct is not permissible |
YJLY | Aluminum conductor, XLPE insulated and PVC sheathed power cable | |
YJY | Copper conductor ,XLPE insulated and PE sheathed power cable | |
YJLY | Aluminum conductor ,XLPE insulated and PE sheathed power cable | |
YJV22 | Copper conductor ,XLPE insulated, steel tape armoured and PVC sheathed power cable | For laying indoors , in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force |
YJLV22 | Aluminum conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable | |
YJV23 | Copper conductor ,XLPE insulated ,steel tape armoured and PE sheathed power cable | |
YJLV23 | Aluminum conductor ,XLPE insulated ,steel tape armoured and PE sheathed power cable | |
YJV32 | Copper conductor, XLPE insulated, steel wire armoured and PVC sheathed power cable | For laying indoors , in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force . |
YJLV32 | Aluminum conductor ,XLPE insulated, steel wire armoured and PVC sheathed power cable | |
YJV33 | Copper conductor ,XLPE insulated ,steel wire armoured and PE sheathed power cable | |
YJLV33 | Aluminum conductor ,XLPE insulated ,steel wire armoured and PE sheathed power cable |
Production range of cable
Type | Nomber of cores | Rated Voltage kV | ||||||
3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | ||
Nominal cross-section of conductlr mm2 | ||||||||
YJV | 1 | 25-800 | 25-800 | 25-800 | 35-800 | 50-630 | 50-630 | 50-630 |
3 | 25-630 | 25-630 | 25-500 | 35-500 | 50-400 | 50-400 | 50-400 | |
YJV22 | 1 | 25-800 | 25-800 | 25-800 | 35-800 | 50-630 | 50-630 | 50-630 |
3 | 25-630 | 25-630 | 25-500 | 35-500 | 50-400 | 50-400 | 50-400 | |
3 | 25-630 | 25-630 | 25-400 | 35-400 | 50-240 | 50-185 | 50-150 |
Workshop
Package & Shipping
- Q: Alright, im most likely moving to Germany in December, and im bringing my PS3 over with me. That I bought here in the US.. Is it possible for me to buy the power cable for a PS3 that works in Germany and plug it into my current PS3, or will it short it out?
- It won't short out, cause it will only take certain power
- Q: I am trying to hook up a LCD display (CPU Temp, USB's in use, Memory Temp/usage, etc) and It came with a 5pin DIN connector for what I assume is the power. I am not sure what I need to do to connect it to the PSU. Any help or ideas?
- I think this device should have a power connector as well as a sensor cable (USB in use should have a connector running on to your motherboard.) can you provide me the make/mode number of the equipment. Also provide me with a link so that i could see the connectors and wires and the device. Else take a pic, upload it some image hosting site and provide with a link. (you can edit your question or add additional info and provide a link. Replace the http with hxxp, if the link is getting blocked)
- Q: I need to run power cables from 4 fans on my stacker 830 around the edges of the case and into the power supply for cable management purposes. The fans I currently have, have power cables that are around only 10 inches long. Any ideas?
- Can you solder? If so, just clip the wires then splice on extensions. Add heat-shrink material, solder connections, shrink the material and you're good to go.
- Q: I'm gonna build a pc, the graphics card is an XFX Radeon 6970 and the power supply is a cooler master 750w. Im new to this and I dont want to buy a cable online and have it be the wrong one
- Well, you really shouldn't build a PC if you don't know what you are doing.
- Q: The hard drive is: Western Digital Caviar SE WD3200AAJS 320GB 7200 RPM, I'm getting from Newegg OEM. I know that OEM's don't come with a SATA cable which is fine but where can I find a compatible power cable? If it comes with one already please let me know. Thank you in advance.
- An internal drive would be powered by your power supply. If you don't have any additional SATA power cords in your PC, I believe you can by a 4 prong to SATA converter. Otherwise you may have to look at getting a new power supply for your PC that has more SATA power adapters
- Q: I am getting a new 160 amp high output alternator for my 2005 Mazda 3 2.3L. I am running a 1000w amp with two subs. I have the stock alternator in it right now. There are two power cable kits available for me to get. One that has 4 gauge wire with a 100 amp fuse and the other, 1 gauge with 150 amp fuse. Which kit should I get? Can I just add 4 gauge wire along with my stock wire instead of the 1 gauge kit? What are the fuses for and which one would work better? I know nothing about this. Thanks.
- I would go with the 1 ga wire. The fuse keeps the wire from setting your car on fire. The size of the alternator does not matter. The battery should supply 700 amps or so.
- Q: Hi, I have a router connected to the internet, but one of the computer is 80 feets away from the router and it can not get 100MBps. I have force the computer to use 10MBps. Could someone please let me know what will impact the speed of cat5 cabling?
- Ok, please note the following: MB/s = MegaBYTES per second Mb/s = MegaBITS per second 10MB/s = 100Mb/s (roughly) Your router and NIC card is 100Mb/s (unless they are both Gigabit - Gb/s which will give you roughly 100MB/s in speed assuming both the NIC and router can support that speed.) I hope this answers your question.
- Q: im curious what a good rule of thumb would be for determining how strong a fuse to put in line to the amp. im getting a 2300 watt amp but dont know how many amps of fusing it uses. so i dont know its power draw. any help would be great
- current(A)=power(W) / voltage(V) go with Jeffs answer so you can blow them all-idiot do the math! 2300/12=191A! How hard is that!
- Q: So I use my laptop with power and only put in the battery when I take it around. So I sat my computer down and it abruptly just shut down. I powered it on and I set it down again and the same thing happened. The third time it went all the way to the desk top. I touched and moved around the power cable connected to it shut down. WTF
- sensitive power supply connection i guess
- Q: Sometimes I have to jiggle the chord or plug it in the right position to get the laptop to be charged. At first, I thought it was the power cable, but after buying a new one, I still have the same problem. Any suggestions as to what causes this and how to fix it?
- The power jack internal to the laptop, is probably faulty, not the cable. If your laptop is under warranty I would look at filing a claim to get it fixed.
Send your message to us
XLPE insulated copper conductor power cable
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 1000000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords