High Voltage XLPE insulated copper conductor wire and cable
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 1000000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
High Voltage XLPE insulated copper conductor wire and cable
1.Factory price
2.international standards
3.fast delievery
Executive standard
International: IEC 60502-2, IEC 60228, IEC 60840, IEC62067
Chinese: GB/T 12706.1~12706.3-2008
Other standards such as BS,DIN and ICEA upon request
Applications
For laying indoors , in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force .
The product is suitable for use in power transmission and distribution lines with ra
power frequency voltage 3.6/6kv~26/35kv.
Operation characteristics
Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv
Max. admissible operating temperature of the conductor:90℃
Max. short-circurt temperature of conductor shall not exceed 250℃.
(5s maximum duration)The ambient temperature under installation should not below 0℃
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a three-core cable should not less than 15 times of the cable diameter.
Type of cable
Type | Designation | Application |
YJV | Copper conductor, XLPE insulated and PVC sheathed power cable | For laying indoors , in tunnel or cable trench, unable to bear external mechanical forces. Single-core cable in magnetic duct is not permissible |
YJLY | Aluminum conductor, XLPE insulated and PVC sheathed power cable | |
YJY | Copper conductor ,XLPE insulated and PE sheathed power cable | |
YJLY | Aluminum conductor ,XLPE insulated and PE sheathed power cable | |
YJV22 | Copper conductor ,XLPE insulated, steel tape armoured and PVC sheathed power cable | For laying indoors , in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force |
YJLV22 | Aluminum conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable | |
YJV23 | Copper conductor ,XLPE insulated ,steel tape armoured and PE sheathed power cable | |
YJLV23 | Aluminum conductor ,XLPE insulated ,steel tape armoured and PE sheathed power cable | |
YJV32 | Copper conductor, XLPE insulated, steel wire armoured and PVC sheathed power cable | For laying indoors , in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force . |
YJLV32 | Aluminum conductor ,XLPE insulated, steel wire armoured and PVC sheathed power cable | |
YJV33 | Copper conductor ,XLPE insulated ,steel wire armoured and PE sheathed power cable | |
YJLV33 | Aluminum conductor ,XLPE insulated ,steel wire armoured and PE sheathed power cable |
Production range of cable
Type | Nomber of cores | Rated Voltage kV | ||||||
3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | ||
Nominal cross-section of conductlr mm2 | ||||||||
YJV | 1 | 25-800 | 25-800 | 25-800 | 35-800 | 50-630 | 50-630 | 50-630 |
3 | 25-630 | 25-630 | 25-500 | 35-500 | 50-400 | 50-400 | 50-400 | |
YJV22 | 1 | 25-800 | 25-800 | 25-800 | 35-800 | 50-630 | 50-630 | 50-630 |
3 | 25-630 | 25-630 | 25-500 | 35-500 | 50-400 | 50-400 | 50-400 | |
3 | 25-630 | 25-630 | 25-400 | 35-400 | 50-240 | 50-185 | 50-150 |
Workshop
Package & Shipping
- Q: I am dead!!! My mom and Dads' Town Country is old, a 1996, but my dad loves it. He keeps it looking new. He will never get rid of it. I am 20y/o and screwed up. I slammed the driver side door and when I tried to roll it up, the back came up. Not the rest. I took the door apart, and there are cables all undone, and I don't know what the hell to do. I don't have a lot of money or time. They will be back in three days. I called the dealer, they said $300.00. I'm toast. Can anyone save me from this death sentence?
- the regulator is broken. the cable broke and came out. it happens all the time. it wasn't because you slammed the door, it was old age. the only thing you can do is replace the regulator. if you were smart enough to get the door panel off you should be able to replace the regulator. its pretty self explanatory. you may be able to get a regulator at a parts store, i'm not sure on this van. the one from the dealer won't be that much if you do it yourself. if you have them do it, its the regulator plus 1.5 hours labor.
- Q: my tv is mounted on the wall, and my friend came round and we tryed to plug in his ps3 and we knocked the main power plug from the tv.we have fiddled about for around an hour looking for wer it came from and need help before my mam gets back!
- Ignoring all the upfront on-line research I undertook, I made 8 separate visits to the showrooms of the 'usual suspects' in UK electrical retail I was so torn between the sony panasonic 42 offerings!! As a brands snob I wanted the Sony because I wanted a sony on my wall.. But every time I viewed the TV's in various store environments I kept getting drawn back to the simplicity if the panasonic's operation, the depth of tone / image on screen vs. the sony. After much consideration I went for the panasonic as (for me) it's a better TV to watch TV on!.. Technically the sony has a faster refresh rate plus slightly more advanced image 'in-fill' technology and technically it should therefore give a
- Q: Hello,if you want to split your power distribution cable,how do you do so ?? I want the cable to be divided into two other smaller cables,do I use a T-joint or what ???Thx!!!
- What sort of power cable? If it is mains or an automotive power outlet, you can get splitters for those.
- Q: I lost my power cable for my Ipod Shuffle 2nd Gen, can I use the 3rd gen shiffle power cord for the 2nd gen? My logic: $55 for a new ipod 3rd gen or $30 for a new power adapter for the 2nd gen. $25 more I have a new ipod... but it would be nice if I can still use the 2nd gen as well...
- look and see if the adaptor will fit...if so it should...i doubt they will though
- Q: Hi everyone,I attempted to build my first PC; purchased the hardware, software, etc. Everything is assembled perfectly.After installing the motherboard, power supply and the respective cards, I connect the power cable.Upon connecting the power cable, the PC turns on and the only way to turn it off is to remove the power cable (from the back of the PSU). The PC boots up as if I pressed the power button!!I've read that this problem could be the power supply or the capacitors on the board??I'd be appreciative for any advice,Thanks,p
- Hmm that sounds like you have missplaced the cables to the motherboard from the front pannel (on switch, HDD led etc.) Kenny
- Q: I am trying to find a 4 Pin Fan Power Splitter Cable or my computer since I only have 1 4 Pin Fan Power jack and I want to use 2 4 pin fans. I am having a really hard time trying to find one in hamilton
- Before hooking that up, check the specs on your motherboard to see if that fan header will support loads from both fans. You may need to get a Molex to 4-pin converter and power directly off your power supply.
- Q: I took a vacation last week in Victorville, Ca and i brought my 360, well when i was ready to come back home i packed everthing but my Xbox 360 power cable, now im stuck at home and can't play my 360 or nothing..=[. And i don't wanna order it online. I need some help where to find this.
- are u missing the whole power source or just the end cable? the end cable is the same power cord has a computer
- Q: What are the phone, power, and cable companies in Pomona, Ca?
- Verizon for phone SCE (So cal edison) for power Charter? for cable I think. Get Direct TV it's better Gas is So cal gas.
- Q: i wanna know how much distance should be in between the power cable and the cat5 cable
- standard used to be 185 feet somewher 100 meter ,I am not sure what you mean by to power ......
- Q: I was just wondering that if, for example, you are running too small of a power cable to you subwoofer amplifier does it not get to its full potential? And, if you get the right size will it be louder? Your thoughts and recommendations would be appreciated.
- nope, gives you better current and better connection. think of a taking straw you use for stirring Coffee compared to one of those jumbo straws. Youll get alot more liquid through the jumbo straw. So basically with thicker wiring the power is already there when it needs it instead of sucking it from the alternator.
Send your message to us
High Voltage XLPE insulated copper conductor wire and cable
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 1000000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches