• Diaphram Pump System 1
Diaphram Pump

Diaphram Pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications:

Perfect for caravans, boats, motorbikes, trucks and camping. Use it with fresh or salt water with your deck wash or to run your toilet or shower. These pumps automatically turn themselves on and off when you turn the tap on and off. Comes with filter and fittings. These pump are for intermittent use only.

A great pump for those country folk, with a small family, on tank water who only need to boost the pressure from a tank next to the house.

We have tested these pumps and found they will operate to a 2 metre suction lift and 5 metre head with no problems.

1.Maximum torque and operating efficiency/higher operating pressure and/or lower amperage than competitive pumps

2.Long life, no leaks, strong corrosion resistant

3.12/24 VDC and 115/220 VAC motors standard (consult factory for other voltages)

4.Quality components for extreme performance

5.Numerous fitting options for greater mounting flexibility

6.Voltage:12V/24V DC Diaphragm Pump,115V/230V AC Diaphragm pump

7. Expecially suitable for marine and recreation vehicle, such as boat and ship.Also suitable for Agriculture sprayer

 

Features

  • Lightweight and made from non corroding materials

  • Self priming

  • Run dry Protection

  • Easy to install

  • No maintenance

  • Simple to operate

  • Low power consumption

  • 12 months warranty

  • Automatically turns on and off

  • Comes with filter and fittings

How a Pump Works

The pump is driven by an AC or DC motor

In front of the motor is a valve assembly containing two to five valve pump chambers. Each valve chamber has a diaphragm behind it in the lower pump housing. As the motor shaft turns, an internal cam positioned behind the diaphragms causes the diaphragms to be pushed forward, then back in a continuous sequence creating a suction. As this suction builds, fluid is pulled hrough the inlet, through the various valve chamber check valves to the outlet he volume of flow is determined by several factors including: the number and size of the pump chambers,cam offset, operating pressure, fluid viscosity.


Q:What's the submersible pump?What is a submersible pump, and what about it?
Submersible pump is a pump directly on the water inside the pump, eliminating the water inlet pipe, eliminating the trouble of ordinary water, is very convenient, just a pool, pool, bucket, water tank water level is shallow to be able to work, meet your requirements of pumping drainage
Q:How does the centrifugal pump pump and cut the pump?
Check the motor, pump and fasteners in good condition; whether the lubricant is added or not;Disc dynamic coupling, whether or not stuck phenomenon;Open the inlet valve, remove the gas in the pump or pump the gas out of the pump;
Q:Water pump spoon pipe for power plantWhich hero can tell me what is the water pump spoon tube ah? And its role
Then control the speed level, to achieve the purpose of regulating the speed and flow of the feed water pump.
Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q:Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
The direct connected pump impeller is directly mounted on the motor shaft, and the non direct connected pump and motor are two shafts, and the two shafts transmit torque through the coupling
Q:What are the main performance parameters of hydraulic pumps?
speedOperating speed is the actual rotation speed of a pump (or motor) at work.Rated speed is the maximum speed that can operate normally for a long time under rated pressure. If the pump exceeds the rated speed, the work will cause insufficient oil absorption, vibration and noise, the parts will suffer cavitation damage, life expectancy.Minimum steady speed is the minimum speed allowed for normal motor operation. At this speed, the motor does not appear crawling phenomenon.
Q:How many square cables does the submersible pump for 7.5KW need?
According to current I=13A, it is estimated that the cable is less than 10 square meters, so the cable cross section can be calculated at the ampacity of 5A per square meter. The square section of the cable is =13/5=2.6 square. According to the specifications series, optional 2.5 square aluminum cables. When the cable is longer, it is safer to choose 4 square aluminum cables.
Q:What is the function of the heating pump system for the water pump design?
As the feed water temperature is higher, in the case of non warm pump start, will make the pump body is subject to greater thermal impact; in addition, the flow components with the pump contact heating fast, not contact with water directly heating slowly. This expansion due to uneven speed, it will inevitably produce thermal stress, deformation of the pump body, sealing surface, the joint surface is lax and leaking phenomenon. Therefore, the warm water pump system is designed for the water pump.
Q:Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
Because the characteristic curves of the two are different.The power of centrifugal pump decreases with the decrease of flow rate. When the flow rate is zero, the power is minimum, so the centrifugal pump is started with a closed valve.
Q:Working principle and diagram of axial piston pump with pressure compensation variable
The size of the outlet flow pressure compensated variable displacement pump with outlet pressure of approximately in a certain range according to the constant power curve. When the pressure oil from the main part of the channel (a), (b), (c) into the inferior vena cava (d) variable shell, oil by the channel (E) respectively into the channel (f) and (H), when the spring force is greater than the oil (f) into the lower end of the piston ring servo hydraulic thrust area when the oil liquid (H) to the chamber (g), push the variable downward movement of the piston, the pump flow increases. As for the hydraulic servo piston end thrust force ring shaped area is greater than the spring when the servo piston moves upward, blocking channels (H), the (g) (I) through the cavity of the oil cavity pressure relief, at this time, the piston moves up, the variable head angle decreases, the pump flow rate decreases.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords