DN200 Spectacle Wear Plate for Schwing Concrete Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 1000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product Description:
Product Name: DN200 Spectacle Wear Plate for Schwing Concrete Pump
1. Specification
Size | DN150, DN180,DN200,DN230 |
Material | tungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany |
Lifetime | 30,000-80,000cbm |
Carbide HRA | > 86 |
Electrode HRC | > 63 |
Type | hardfaced, tungsten carbide and 7 shape tungsten carbide |
Application | mud pump, shotcrete,trailer and truck mounted concrete pump |
Manufacturer with competitive price |
2. Application
Spare parts for mud pump, shotcrete,trailer and truck mounted concrete pump
3. Package
Plastic bag and carton box, also according to your requirements |
FAQ:
Q1: Why buy Materials & Equipment from OKorder.com?
A1: All products have its ISO certifications, adheres to the highest standards and a commitment to supply chain safety and customer satisfaction.
Q2: How do we guarantee the quality of our products?
A2: We have established an advanced quality management system which conducts strict quality tests at every step, from raw materials to the final product. At the same time, we provide extensive follow-up service assurances as required.
Q3: How soon can we receive the product after purchase?
A3: Within three days of placing an order, we will begin production. The specific shipping date is dependent upon international and government factors, but is typically 10 to 30 workdays.
Q4: If we can produce DN260 Spectacle Plate for SANY Concrete Pump according to customers request?
A4: Yes, we can produce DN260 Spectacle Plate for SANY Concrete Pump according to the difference country situations to make it suitable to the market and customers. We have very professional technical team to make the design.
Q5: How to make a quick resolution for after service?
A5: We have overseas branches all-around of world, If needed, the seller shall dispatch 2 engineers to the buyer's site for supervision of training. The buyer shall make available of necessary facilities &skilled personnel at site for training.
Images:
- Q: Working principle and diagram of axial piston pump with pressure compensation variable
- Adjust the flow characteristics, the first limit screw to the top, according to the flow and pressure changes in the required range, adjusting the spring set, the initial flow pressure began to change to meet the requirements, then the limit screw to the ultimate pressure when the flow is no longer changed, the relationship between flow and pressure the changes are determined by the pump itself.
- Q: Fire pump and shower pump flow head selection, high resolution.
- 2, the volume is greater than 10000 is less than 25000, the minimum water consumption of indoor fire hydrant is 15L/s
- Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- Such as a large pressure of about 10m or about 0.1MPa} because the most unfavorable point fire hydrant requires more than 0.07MPa (7m) and 0.5MPa (50m) is not greater than the pressure, so unless the pump is located in the 50m Valley is still lower than the garage, or add to the valve (or the use of fire hydrant decompression) otherwise, it is 120m lift pump
- Q: 5 floor water pressure is too low, what kind of water pump is better?
- The location of the pump is too far away from the pumping pool, the suction of the pump is not enough, cavitation phenomenon, pumping water, this water pump manufacturers, the pump will be placed in a reasonable position
- Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
- The function of vacuum pump is to make vacuum, which has many kinds of structure, such as centrifugal, diaphragm (diaphragm), piston, liquid ring, rotary plate, jet type...................
- Q: The main factors affecting the performance of centrifugal pumps
- The specific speed is deduced by the law of hydraulic similarity, and the similarity between the hydraulic characteristics of centrifugal pumps is similar. In centrifugal pumps, the specific speed is often interpreted as: the pump works at the highest efficiency, generating a lift of LM, a flow rate of 0.075m, and the power consumed by the /s at 0. 735kW
- Q: Rules for operation of centrifugal pumps
- 5, before you stop, you should gradually close the outlet valve, then turn off the power supply.6, with the check valve line, in ensuring the check valve intact, without closing the outlet valve, check the pump cavity, no air can be directly switched on.
- Q: What flowmeter is installed after the pneumatic diaphragm pump?
- Compressed air source, the general pneumatic diaphragm pump starting gas source for 0.1~0.2mpa,The maximum working pressure is 0.7~0.8mpa, so in this pressure range, you can use the air filter relief pressure valve gas pipe, adjusting for air pressure, when the pressure is bigger, diaphragm movement faster, so the greater the flow, and vice versa
- Q: What are the characteristics of the piston pump?
- Piston pump is an important device of hydraulic system. It depends on the plunger in the cylinder in reciprocating movement, so that the volume of the sealing chamber volume changes to achieve oil absorption and oil pressure. Plunger pump with a rated pressure, compact structure, high efficiency and flow and easy adjustment, is widely used in high pressure and large flow and flow needs to adjust the occasion, such as hydraulic machine, engineering machinery and ships.
- Q: Significance of water pump model ISO50-160
- According to different working principles can be divided into volumetric pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.
Send your message to us
DN200 Spectacle Wear Plate for Schwing Concrete Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 1000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords