Lightly Galvanised Iron Wire For Gabions
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Hot Dip Galvanized Steel Wire
(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .
(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .
(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.
(4) Tensile Strength Range
Size (mm) | Tensile Strength (mpa) |
0.15-1.60 | 290-550 |
0.65-1.60 | 400-550 |
1.61-6.00 | 400-1200 |
(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.
(6) Packing
Size (mm) | Coil Size | Spool Packing | Big Coil Packing | |
ID (mm) | OD (mm) | |||
0.15-0.26 | 6 inch | 1-14kg/spool |
|
|
0.27-0.60 | 8 inch | 1-100kg/spool |
|
|
0.61-1.60 | 12/14/16 inch | 1-100kg/spool | 250-400 | 400-770 |
1.61-6.00 |
| 14-500kg/spool | 450 | 800 |
508 | 840 |
(7) Zinc Coating
Meet GB/T 15393 standard.
Size (mm) | Weight of Zinc-Coating ( g/m2 ) | |||||||
A | AB | B | C | D | E | F | ||
A1 | B2 |
|
|
|
|
|
| |
≤0.25 |
|
| 30 | 20 | 18 |
|
|
|
>0.25-0.40 |
|
|
| 30 | 25 | 20 |
|
|
>0.40-0.50 |
|
|
|
| 30 | 20 |
|
|
>0.50-0.60 |
|
|
|
| 35 | 20 |
|
|
>0.60-0.80 | 120 | 110 |
|
| 40 | 20 |
|
|
>0.80-1.00 | 150 | 130 |
|
| 45 | 25 |
|
|
>1.00-1.20 | 180 | 150 |
|
| 50 | 25 |
|
|
>1.20-1.40 | 200 | 160 |
|
| 50 | 25 |
|
|
>1.40-1.60 | 220 | 180 |
|
| 50 | 35 | 30 |
|
>1.60-1.80 | 220 | 180 |
|
| 70 | 40 | 30 |
|
>1.80-2.20 | 230 | 200 |
|
| 80 | 50 | 40 |
|
>2.20-2.50 | 240 | 210 |
|
| 80 | 55 | 40 |
|
>2.50-3.00 | 250 | 230 |
|
| 90 | 70 | 45 |
|
>3.00-4.00 | 270 | 250 |
|
| 100 | 85 | 60 | 30 |
>4.00-5.20 | 290 | 270 |
|
| 110 | 95 | 70 | 40 |
>5.20-6.00 | 290 | 270 | 245 |
| 110 | 100 | 80 | 50 |
- Q: so im lost in how i should wire my subs. I have two subs that i need to wire both are 2 ohms 400 watts i don't know if i should wire them parallel or series if you can help me out that would be great!
- usually all sub wiring is the same, youll have the rca cables and antenna wire comming from the radio to the amp, power and ground wire going from amp to battery and ground, and than should have 2 wires coming off each sub to the amp, im guessing thatd be parallel, if you wire in series, so like use 2 wires and splice off to each sub, so 2 wires off the amp powering each sub you would up the ohms and put a too much of a load on the amp, people only wire in series when they have too many subs and not enough outlets on the amp, good luck
- Q: Hi i would like to ask what is the diference between the two versions of wiring the RJ 45 connector. when I was making my first networking cable, i used the wiring according to an image that only was using/connecting four wires into the connector. the cable works and works well. Now i found plenty of other images, all of them reccomending the full /eight wires/ connecting. Do I run my network on lower Mbits/sec? what are the other four wires used for? Thanks
- In 10/100 Mbps wiring only 4 wires are used. 2 for sending data, 2 for receiving data. The other 4 are used for cancelling cross-talk and minimizing other problems associated with the physics of transmission. The wires are arranged in 4 pairs, with each pair twisted. It's the twisting that solves or reduces transmission problems. In Gigabit over copper (1000Mbps) all 8 wires are used, 4 for transmit and 4 for receive. The twisting of the wires is much tighter and the actual connectors on the ends have a smaller tolerance. You should also be aware that there are two major standards for wire arrangement in UTP data cabling - 568A and 568B. You will need to know what standard is used in your network for consistency's sake. Mixing 568A and 568B results in cross-over which may or may not be what you intended. Hope this helps.
- Q: Got a new kenwood stereo to replace the old kenwood one in my VW polo 1998. Workes fine but when I pushed the stereo into my dashboard a wire came out so I pulled it out and put it back in. It worked, but next morning my car battery was near dead, I unplugged the stereo and its fine now. I assume I used wrong wire? Does anyone have a diagram or picture of how it should be wired?
- When you wired it did you butcher the wires or use a wiring harness? With the wiring harness, everything is labeled and color coded. Match colors to the kenwood wiring harness, splice or use butt connectors, plug harness into factory harness and player, attach antenna wire and you're done! If you did butcher the wires and left enough wire, repair the harness and buy a harness kit at your local sound shop, really cheap too! Good luck!
- Q: I am wiring a cd player in my truck is it necessary to get a wire harness that is made for the year make and model of my truck or can I just cut the factory terminals off and just connect the like colors?
- While a wiring harness isn't strictly necessary, It's highly recommended. The wiring color code on an aftermarket head unit will match up properly with a vehicle-specific wiring harness. The wire colors of your vehicle wiring will NOT be the same as the wire colors on your aftermarket unit. You have to match the wires up according to function, not according to color.
- Q: What method can be used to detect residual impurities and metal particles on the wire surface?
- Therefore, the removal of metal surface impurities and removal of metal surface oxides, the two are different.
- Q: i need the wire diagram for a kenwood kdcmp4032.... i mainly need to know which wire to hook up the remote wire for an amp.
- it is the blue wire now if there are 2 blue wires the one with the white stripe is the amp remote wire the other is for the power antenna and will only activate when the radio is on as in tuner am/fm not when the cd is playing
- Q: How do they differ from residential wiring?
- Commercial and industrial wiring make extensive use of conduit, cable trays/ This entails explosion-proof or flame-proof fittings, along with the seals and other conduit fittings. Residential wiring, in most cases make extensive use of romex cables without any conduit. Other than these major and a few minor differences, the wiring is actually the same. This is the installation of cables/wires from the circuit breakers to the users. TexMav
- Q: Is it possible for a wire to arc with a nail? The u-nail that hangs the wire to a wooden support beam looks like it was hammered in too far and may have cut through the insulation around the wire. Is this a fire hazard or can I leave it as is?
- Hello, anytime the insulation is broken on the line it can be a potential fire hazard, and yes they can arc or short out. The potential may not be large but with fire it safer to err on the side of caution. Codes vary around the country so check there, but we typically pull the staple and determine how deeply the insulation is really compromised, if it is only through the external shielding an in-expensive way to safely repair it is with a shrink tube type of product. However, if any of the internal strands have been compromised the line would need to be cut and a junction box installed and the wire spliced back together inside the box. Hope this helps:-)
- Q: how to wire a receptacle with 6 wires?
- use 3 wire nuts and 3 jumpers, color to color and then connect the others together. Black wire to the dark screw, white color to the silver screw and the green to the ground connection. If this does not make sense to you contact a local qualified professional electrician to do the work.
- Q: Cant find were to tap the wiring for the puddle lights. Can some one please help!
- i in my opinion only offered a Silverado 1500 on Friday, and that i honestly like it! i appreciate the OnStar, and the XM radio good factors. also, i imagine that's in user-friendly words a extra effective searching truck. As for the experience, that's an truly tender experience, like a Cadillac. mutually, its were given extremely some capacity in the back of it. The warranties are large too. It even comes with a 6 365 days assure on rust! i might want to flow with the Silverado for constructive!
Send your message to us
Lightly Galvanised Iron Wire For Gabions
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords