Galvanized Iron Wire for Binding and Fencing
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 m.t. m.t.
- Supply Capability:
- 1000tons/30Days m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Galvanized Iron Wire
Descriptions of Galvanized Iron Wire
Galvanized wire can be divided into: Electro galvanized iron wire & Hot dipped galvanized iron wire.
1. Material:
Q195, Q235, 1006, 1008, 1010, 1018
We use high quality carbon structural steel wire rod Q195, Q235, 1008, 1018 etc as raw material to manufacture galvanized iron wire
2. Wire Diameter:
0.2mm-5mm
3. Zinc Amount:
10g-360g/m2
4. Tensile strength:
35-50kgs/mm2
5. Elongation:
10% - 25%
6. Packing:
0.2-800kg/roll, with plastic film & woven bag, or plastic film & hessian cloth, or robbins, or as your request.
7. Popular Specifications:
Galvanized Wire | |||
Wire gauge | SWG(mm) | BWG(mm) | Metric(mm) |
8 | 4.05 | 4.19 | 4.00 |
9 | 3.66 | 3.76 | 4.00 |
10 | 3.25 | 3.40 | 3.50 |
11 | 2.95 | 3.05 | 3.00 |
12 | 2.64 | 2.77 | 2.80 |
13 | 2.34 | 2.41 | 2.50 |
14 | 2.03 | 2.11 | 2.50 |
15 | 1.83 | 1.83 | 1.80 |
16 | 1.63 | 1.65 | 1.65 |
17 | 1.42 | 1.47 | 1.40 |
18 | 1.22 | 1.25 | 1.20 |
19 | 1.02 | 1.07 | 1.00 |
20 | 0.91 | 0.84 | 0.90 |
21 | 0.81 | 0.81 | 0.80 |
22 | 0.71 | 0.71 | 0.70 |
8. Applications of Galvanized Iron Wire
weaving wiremesh, baling, armouring cable.
Galvanized iron wire is mainly used in making chain link fence ,barbed wire ,gabion basket, hexagonal wire mesh, crimped wire mesh, expressway wire mesh fence, and more .
In addition,the galvanized wire also can used as binding wire to bind everyday objects.
Corner of Factory
Galvanized Iron Wire
Delivery
- Q: I found an old Karavan flatbed utility trailer and am currently converting it into a snowmobile trailer (2 place). Me and a friend riped all the wire off of the trailer and completely rewired it. No matter how we configure it, the lights aren't coordinated. If we hit the left blinker in the car, all the lights flash(like the hazards are on). Right blinker works fine. we wired it first from the diagram on the karavan site. Now once we think about it, they have us wiring the ground into the light. so we searched the web and found this layout.
- The problem is the difference in 4 to 6 wire . Go to an auto parts store and get the converter . It wires into your car between the plug and the tail-lights .After that , no problem with older trailer wiring .
- Q: 1989 Honda Accord LxWhat is the wiring Diagram for the Stock stereo wiring harness?Just pulled out the old Stereo wanna put my deck in there now but i dont know the cars harness colorss.
- 1989 Honda Accord Car Stereo Wiring Diagram Car Radio Battery Constant 12v+ Wire: White/Yellow Car Radio Accessory Switched 12v+ Wire: Yellow/Red Car Radio Ground Wire: Black Car Radio Illumination Wire: Red/Black Car Stereo Antenna Trigger Wire: Yellow/White Car Audio Front Speakers Size: 5 1/4″ Car Audio Front Speakers Location: Doors Left Front Speaker Positive Wire (+): Blue/Green Left Front Speaker Negative Wire (-): Gray/Black Right Front Speaker Positive Wire (+): Red/Green Right Front Speaker Negative Wire (-): Brown/Black Car Audio Rear Speakers Size: 6 1/2″ Car Audio Rear Speakers Location: Rear Deck Left Rear Speaker Positive Wire (+): Blue/Yellow Left Rear Speaker Negative Wire (-): Gray/White Right Rear Speaker Positive Wire (+): Red/Yellow Right Rear Speaker Negative Wire (-): Brown/White
- Q: the fused ignition wire and illumination wire, i cant figure out where they go on a Dual stereo system model1225 Help. ( on a 1990 ranger )
- the ignition wire is going to be a yellow with a black stripe(car wire) and the instruction manual will tell you for the head unit illumination wire i just taped up since my head unit didnt require it =) like they say...if it turns on it dont need it
- Q: What's the thickness, or measurement for the last or thickest wire?
- some people have just a thin wire that's called a chain(its pretty much any colour you want elastic that stretches from one side to the other), some have a metal chain which is a lot thicker. it all depends on your teeth.
- Q: subs - dvc 4ohm 2 of them 600wattrms on each wiring it to a 1200 watt amp same brand as sub amp is 1 ohm stable to i wire the subs together and then to the amp a 1ohm? that would give each sub 600 watts right?
- myself I even have 2 - jl w6's under pressure to 3 ohms. under pressure to a fosgate 4 channel amp, the two channels bridged and the amp sees a million/2 ohm after bridging and the amp works positive with the best points set at 0 i are not getting the suitable overall performance this type and would desire to cord to 6 ohms. and bridge to 3 ohms and this would be greater suitable yet have not tried it yet will interior the destiny. shop this set up if it sounds reliable yet seem interior the destiny to get an amp or subs that artwork at the same time.
- Q: Ok, I am having trouble installing a new car radio in my 97' Honda Civic Lx. It's just a basic pioneer cd player.. I matched all the colored wires up and still nothing. My brother had told me something about + - for example do i hook the green stripped wire with a flat green wire? Vice versa.. Help please.. Also If you know of a web site with diagrams?
- well if they install it they shood provide them but it will cost you extra
- Q: Which are more secure, wired or wireless networks? Explain.
- Wired networks are always more secure because they're not advertising themselves to the world; e.g. you need to have physical access to connect to a wired network. Wireless networks can be secure; but the fact of the matter is they're advertised to any passer-by and are susceptible to having their keys cracked.
- Q: I have looked up wires for this car but the ones that I have looked up tell me i should have different colored wires. These are the wire colors i have:yellowyellow/blackorangepurple/whitewhiteblue/redgreen/blackpink/blackred/blackblue/orangeyellow/redwhite/redgreen/orangePlease Please Please help me!Thanks,Ash
- 1998 Mazda Protege Lx
- Q: Hello, I have a 4 year old Trane XR12 unit. Recently the compressor fan is noisy, and now stops when when under power after 5-10 min. The main fuses and breakers are fine, the fan spins freely when turned, the contactor pulls in fine, the dual capacitor checks out. But, the wiring of the capacitor does not match wire diagrams. Could this have caused the fan motor to prematurely fail?..............................Terminal: C red wire, FAN brown wire, HERM has both orange and purple. Schematic shows the purple wire should be with red wire on common C. The purple also leads to fan.
- Hi, I looked at the schematic on-line. If you still have the original fan motor in the unit then you are correct. The center terminal on the capacitor should have the red wire from the T1 terminal of the contactor, the red wire from the compressor, and the purple wire from the fan. The FAN terminal should have the brown wire from the fan. The HERM terminal should have the orange wire from the compressor. The black wire from the fan and the black/blue wire from the compressor should lead back to the T2 terminal of the contactor. Again, that is if the motor is the original motor. If it was replaced at some point in time, the wiring colors can change from manufacturer to manufacturer, in which case it's possible that the new motor is wired correctly. There should be a diagram on the motor to show you the correct wiring configuration.
- Q: what are the limitations of international wire transfer
- Usally 3% foren plus bank wire fee included
1. Manufacturer Overview
Location | Hebei, China |
Year Established | 1984 |
Annual Output Value | Above US$ 20 Million |
Main Markets | Mid East; Eastern Europe; North America; America; Europ; Local selling to trade company. |
Company Certifications | ISO 9001:2008; CE; |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Tianjin |
Export Percentage | 70% |
No.of Employees in Trade Department | 200 People |
Language Spoken: | English; Chinese; |
b) Factory Information | |
Factory Size: | Above 30,000 square meters |
No. of Production Lines | Above 5 producce line, 120 units machine |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | reasonable; Average |
Send your message to us
Galvanized Iron Wire for Binding and Fencing
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 m.t. m.t.
- Supply Capability:
- 1000tons/30Days m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords