HV Electric Power Cables Different Types of Electrical Cables for Copper

HV Electric Power Cables Different Types of Electrical Cables for Copper

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT or LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specification

Different types of electrical cables
1.IEC standard Made in China
2. factory price distributor
3, 12 years produce experience

HV/MV/LV PVC/ XLPE/ Copper/aluminum

Armoured/unarmored electric power cables

Different types of electrical cables

 

  Main Electrical Characteristics

   

Type

 

Name

 

Suitable areas

 

Copper-conductor

 

AL-conductor

YJV

YJLV

XLPE-insulated cable sheathed with PVC

Indoor, tunnel, cable channel

YJY

YJLY

XLPE-insulated cable sheathed with polythene

YJV22

YJLV22

XLPE-insulated cable sheathed with PVC and armored with steel tape

Direct burial in the ground and the capacity of bearing certain mechanical force, not proper in the pipeline

YJV23

YJLV23

XLPE-insulated cable sheathed with polythene and armored with steel tape

YJV32

YJLV32

XLPE-insulated cable sheathed with PVC and armored with thin steel wire

The bed of river and shallow sea, as the link line between the two platforms of oil and gas station in the water, the capacity of bearing tensile force.

YJV33

YJLV33

XLPE-insulated cable sheathed with polythene and armored with thin steel wire

YJV42

YJLV42

 

XLPE-insulated cable sheathed with PVC and armored with thick steel wire

YJV43

YJLV43

 

XLPE-insulated cable sheathed with polythene and armored with thick steel wire

 Main Features

Conductor

Compact Stranded Copper Conductor, Class 2 as per IEC 60228

Circular solid Copper Conductor, Class 1 as per IEC 60228

Flexible Stranded Copper Conductor, Class 5 as per IEC 60228

Conductor Screen

Semi-conductor (MV only)

Insulation

XLPE(Cross-linked polyethylene)

Insulation Screen 

Semi-conductor (MV only)

Separate Screen 

Copper Tape (MV must, LV optional)

Filler

PP Yarn, or Paper

Wrapping Tape

PP

Inner Covering

Extruded PVC (MV only)

Armour

Steel Wire, or Steel Tape, or Aluminium Tape or unarmored

Overall Sheath

PVC or PE

 Picture

 

 

Q: Bought 60 Inch Full HD LED LCD Smart 3D TV by Sony while stationed in Germany. it came with a european a/c socket attached, so currently searching for an American socket replacement however I can't seem to find one with the same specs! Model is KDL60W850B
1- if it is a DVB tv (german system), it will not work in the usausa system ATSC . 2- a power cable is determined by x volts y amperes for example 250v and 10a it means you can use it on 250v maximum .more voltage than that damages its insulation material and 10a current maximum more than that current causes the cable gets hot so risk of fire . 3- fortunately the power supply is SWITCHING MODE. so you can use it on 120v .
Q: I am running a LAN Cable through my walls, and I'm using the existing holes for the power lines. I'm wondering if the RF from the power line can interfere with the LAN Cables data. Thanks!
It should be okay, LAN cables are meant to be up to 100 meters long, your shorter cables shouln't pick up too much interference. Also, the wires are shielded and in twisted pairs which helps to negate interference. Not only that but for this reason the network adaptors will be designed to filter out low frequencies.
Q: I need 300 ft. of service entrance cable and I've been told I need 4 guage 3 wire 200 amp aluminum is what I need but I'm wondering if this 1 guage overhead line would work just as well if buried in 2electrical pvc conduit for 300 ft.
Sorry wrong type of cable. The overhead is type SE with a certain insulation type. A 300 foot run will have an appreciable line loss from resistance and hysteresis and when inspected will cause hysterics from the inspector. Hire a qualified professional electrical contractor to do the work properly the first time, faster and easier and possibly the same price as you having to do it and to make repairs later. Also the work of digging a trench that deep is not easy, the contractor has the skills and the equipment and the personnel to do it the first time. This allows you a 2 day time frame instead of 2 weeks. Also pulling the wrong cable that distance is not easy and should be done with the proper power puller. Also #4 Al is not rated for 200 amps.
Q: Why is my 2 Gage power cable from the battery to my amp is to hot and makes a big spark and burns the wire when you meet one end to the other end?
Too hot means the current is very high. Probably in excess of 200 amps. I suspect there is a short in the amp, specially if you tried to connect it hot and drew a spark. That will kill a lot of electronics. .
Q: Cable model YJV4 * 25 + 1 * 16 what does it mean ah
" Why should the closed wall or protective wall closed on the second side of the closed junction box? This need to understand if you do not add this closed junction box, what kind of harm Civil air defense project in the closed wall is divided into the clean area and the area of ??the infected area, and the wire tube in the thread after the inside is a cavity, directly through the wall to communicate with the cleaning area and exposed areas, so wartime works outside the dyeing The poisonous air can penetrate into the clean area through the cavity inside the wire tube, which is harmful to the personnel inside the project And the installation of a sealed junction box, you can thread in the line after the box filled with sealing material to block the tube cavity connectivity This is why the electrical safety pipe in the air defense project must pass the closed wall or protect the closed wall when the two sides must be closed in the closed junction box reasons
Q: My mother has moved to Australia, taking her Fujitsu Siemens (Amilo model) laptop with her. Very shortly after, her power cable stopped functioning, and she would like a new one. Unfortunately, she is not tech-savvy at all and doesn't seem to be able to find the thing online, and I being from Europe, have trouble searching in her stead. I don't even know what an Australian plug looks like and I have no clue regarding the currency...All and any help is much appreciated.
Just get a small plug adapter in Australia. That will be cheaper than buying a whole new power cable.
Q: cable or do they need certain ones, I ask because this PSU: has no power cable with it so will i have to get a certain power cable for that wattage or are they all the same???please answer, 10 points for first answer
They all follow the same 3 pin power cord externally but they are not the same internally ie from the motherboard to the PSU.
Q: The cylinder is in the power cable about 2 inches from the connection to the laptop and is about one half inch diameter by one inch long. Does it serve an electronic function or is it just a mechanical assist device?
It's called a choke. It's used to filter out unwanted radio interference.
Q: It isn't the standard power cable, it ALMOST looks like a power cable for a playstation, except it has round on both sides and not just one...Can I JUST buy the plug for it? I lost it when we moved and I need it to make Xmas Cards HAHA
Check okorder they may have part and express shipping Merry Christmas
Q: Silicone rubber insulated power cable blistering, stomatal reasons What are the improvements?
Surface brush fireproof paint is the fire-resistant bridge by fire time sub-level two three times as if 30 minutes 45 minutes and 60 minutes fire bridge should be lined with inorganic fire board, but this is very high in the general very little useful

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords