• Hot Dipped Galvanized Welded Wire Mesh For Fencing System 1
Hot Dipped Galvanized Welded Wire Mesh For Fencing

Hot Dipped Galvanized Welded Wire Mesh For Fencing

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
3 m.t.
Supply Capability:
100 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Welded Wire Mesh

 

1.Material: 

superior low carbon steel wire, galvanized wire , stainless steel wire,PVC coated wire

 

2.Surface treatment:

electro-galvanized, hot-dipped galvanized, PVC coated

 

 

3.Manufacture process: 

The galvanized electric wire mesh, welded after galvanized electric welded mesh and plastic coated mesh are made with high-quality iron wire by automatic equipment.

 

 

4.Feature: 

 smooth mesh surface ,well proportioned meshes,strong welded points and bright luster . The mesh doesn’t come loose even if cut in parts or being exerted force on parts .Compared with general iron  wire ,the products are better in respects of anti-corrosive and anti-rust .

 

5Usage:

 It is  widely used in industry, agriculture, construction, transportation,mining etc  

 

6. Specification List

 

(Standard welded wire mesh)30m length,width 0.5m-1.8m

hole size

wire gauge(BWG)

inch

mm

1/4" x 1/4"

6.4 x 6.4

22,23,24

3/8" x 3/8"

10.6 x 10.6

19,20,21,22

1/2" x 1/2"

12.7 x 12.7

16,17,18,19,20,21,22,23

5/8" x 5/8"

16 x 16

18,19,20,21,

3/4" x 3/4"

19.1 x 19.1

16,17,18,19,20,21

1" x 1/2"

25.4 x 12.7

16,17,18,19,20,21

1-1/2" x 1-1/2"

38 x 38

14,15,16,17,18,19

1" x 2"

25.4 x 50.8

14,15,16

2" x 2"

50.8 x 50.8

12,13,14,15,16

 

 

( PVC coated welded wire mesh)30m length,width 0.5m-1.2m

hole size

wirre gauge(BWG)

inch

mm

1/2" x 1/2"

12.7 x 12.7

16,17,18,19,20,21

3/4" x 3/4"

19 x 19

16,17,18,19,20,21

1" x 1"

25.4 x 25.4

15,16,17,18,19,20

Q: im assuming red to red and black to black? but then what about the extra green and white wires in the iphone cable? where do they go?
Those are the USB wires. For a charger, they need connected through voltage setting resistors.
Q: I'm trying to use a stereo wire instead of a mono wire for an output from a circuit I've built. The problem is, the gold wire has been cut too short, and I'd rather not strip it back any further since I don't have a lot of cord to work with. Since there are three wires (red, white, gold - ground) can I use either the red or the white as output, and the remaining color for ground, or do I have to use the gold cable for the ground and let the remaining wire dangle (taped)?Thanks
They're just wires - you can do what you want with them. You run the risk of forgetting that you've ignored the colour coding though!
Q: How is commercial wiring differ from residental wiring in design,operation and etc?
This Site Might Help You. RE: Residental Vs Commercial Electric Wiring? How is commercial wiring differ from residental wiring in design,operation and etc?
Q: I am replacing an outside floodlight, the cable from the house has 4 wires (black, brown, grey and yellow), but the floodlight has the standard 3 live, neutral and earth fitting. How would I wire the new floodlight.. the wiring for the old floodlight is less than a year old on a house rewire.Thanks!
Four wire power cables used to be used for 2 and 3 phase power. You would normally provide floodlight power with the use of 3 wires. How long is the cable length from house to floodlights? I would look to see what your source wire colors are and try to match those. It used to be in the USA that the red wire was used to carry the 120/240 Volts AC (50 ~ 60~ Herz). The Black wire was considered the return or negative line; and if you have a green wire it is used to put an earth ground on all the shielding, metal jackets, etc.
Q: What exactly is a quot;Jumping Wirequot;? What are the most common methods of motor vehicle theft? Is there any other option that stealing the keys or hot-wiring it?
GO straight to jail do not pass go and do not collect $200!
Q: I am trying to test a engine coolant temperature sensor (ECT), and in one of the tests it states quot;connect the terminals of the electrical connector with a jumper wirequot;. Where can I find a jumper wire? Does it has to be an specific gauge or any jumper wire? please helpd
Jumper wire is just any piece of wire that allows you to connect two other wires/terminals whatever. You could probably even use a paperclip if it will fit, just have to be careful when jumpering that you don't let the bare material short to ground.
Q: How do they differ from residential wiring?
Commercial and industrial wiring make extensive use of conduit, cable trays/ This entails explosion-proof or flame-proof fittings, along with the seals and other conduit fittings. Residential wiring, in most cases make extensive use of romex cables without any conduit. Other than these major and a few minor differences, the wiring is actually the same. This is the installation of cables/wires from the circuit breakers to the users. TexMav
Q: The wires I have are: 1 red starter cable, 1 tan wire, 1 ground wire to the engine block, 1 red wire to the battery, and 1 red wire that splits into the fuse and into the junction strip. Really need to know which wires go where on the solenoid.
Jtex has the right answer if you bought the right solenoid. Unfortunately- the Ford automotive solenoid is an exact replica, but wired different. So less you got the part from Mercury -your going to burn wires as the Ford puts power to one of the small terminals and the Mercury wants a ground to the same terminal as it's ground is regulated by the neutral no start switch.
Q: I got a ventilation fan for the bathroom. The fan has 2 wires and there are 2 wires sticking out of the wall.How do I know which wire connects to which wire?What would happen if I connect the wrong wires?
The fan will run no matter which way the wires are connected. The AC that is going to run the fan has no specific polarity like DC does. The only question would be safety. See if there's a green screw anywhere on a metal part of the fan. If there is, you should run a ground wire to it. There might not be, and in that case, because the fan only has 2 wires, it must be double insulated and will pose no shock hazard. You've probably seen electric drills with no ground wire. These are double insulated and are safe to use without a ground wire.
Q: Ok so I bought a blower and barrow at the junk store... Figured I could use a v-belt to drive it with this old motor I have... Homemade dust collector!!! Anyhow I have no Idea how to wire it up... I know it probably needs a capacitor but thats about it... It's an Emerson... Has orange, blue, brown, white, and black. Any Ideas would be great! On the sticker it list three different speeds (rpms) So i'm guessing I don't need all the wires and some are just quot;taps.quot;
i think of you have enormously plenty responded your individual questions. The drain is clogged as they generally get with out each year maintenance or a minimum of two times a summer season pouring bleach in the path of the line. And besides, it has probable broken the blower motor. One issues for specific although, by no ability attempt and repair the unit or look at it with out first turning the capacity off to the kit which it variety of feels which you ignored to do. I additionally undertaking to assert that somebody has at one time replaced that blower motor because of the fact your description of the wires might point out that it wasnt production facility set up anymore.however the provider tech which you will might desire to call and time table an appointment with would be waiting to repair and replace mandatory aspects. go away something as much as the pros

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords