• High Quality Electro  Galvanized  Wire System 1
  • High Quality Electro  Galvanized  Wire System 2
High Quality Electro  Galvanized  Wire

High Quality Electro Galvanized Wire

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


Packaging & Delivery

Packaging Detail:spool packing: 0.70-1.30mm 14-100kg ; coil packing: 0.70-1.30mm 2-100kg ; coil packing: 0.70-1.30mm max 350kg 20 tons/20'FCL. there is a layer of plastic film on the surface of hot galvanized iron wire for away from air
Delivery Detail:as quickly as possible

Specifications

size of electro galvanized wire0.70--1.30mm+/-0.01;
retensile strength300--490N/mm2;
elongation:min15%;
zinc coated10-15g/m2.

Scope of application:
 armouring wires for cable;reinforcing wires for high pressure hoses;wires for wearing ,netting;wires for filter



H.S numberproducts name

dia (mm)

 allow tolerance

    (mm)

 tensile strength

   (N/mm2)

elongation


zinc coated

  (g/m2)

product number
72172000electro galvanized wire0.70-1.30   ±0.01   300--490 min15%   10--15JQ--006
packing:




       packing          size of product(mm)     weight(kg)
  spool packing               0.70--1.30       14--100
  coil   packing               0.70--1.30        2--100
  coil   packing               0.70--1.30      max 350


Q: I am doing wiring in my shed on preexisting light fixtures and outlets. the wiring that was disconnect from that carried the electricity to it. What I am trying to do is have all the light fixtures work of an extension cord. I have another extension wire connected to that with the +, - and 0 showing. The fixtures have 3 wires coming out of them what I think to be the power in, power out, and switch. On the fixture on the end I connected my extension cord thing and it work, BUT only that one. The rest of the fixtures did not work, I do see anything wrong. What I thought was that I was connecting to the switch wire so I changed it and it just buzzed with blue light. What is going on?
A typical light fixture has three wires: black, white and green (or uninsulated copper). If there is no green or uninsulated copper wire, there is generally a ground terminal where the ground wire should be attached. The smaller of the two slots in the extension cord (assuming U.S.) is the hot wire and that's where the black wire should ultimately be connected. The white wire nuetral is connected to the other side, the wider of the two slots. The ground is connected to the U shaped terminal below the two slots. There must be a thousand websites with instructions on how to wire a light fixture. Try getting a diagram from one of them.
Q: How to connect a 5 wire Harley LED tail light
The 5 wires to hook up the tail light and directionals. The tail light should take 3 wires. There should be a common ground which is the black / white wire. The white/ black wire and the brown wire are for the tail light(BR) and brake light (W/B). Easieset way is to take a test light to each of the wires. turn the ignition on, connect the test light to the wires one at a time. There should only be one wire that lights (tail light) then press the brake, there are two of those that should come on. Your original had two white/black wires because there were two bulbs in the original tail light. I would just use one white/black and cap the other one. Hook two to the tail light (W/B, Br) plus the black / white wire to ground of your new light. Then turn on one directional and there should be one that blinks with the test light and then the same for the other directional. wire one each to left and right plus to the black/white wire if each directional requires the ground.
Q: Replaced the old fan in my bathroom (about 10 years old) with a new fan. Trouble is this. The fan and light each work on a seperate bathroom switch. I have two spots to install the wire on the new bathroom fan/light. One for the fan and one for the ligth. However, the wiring has one white, one black, one red and the ground. Anyone know what the red is? Can I just cap it off? According the bathroom fan wiring it says something about connecting red to blue. I am slighty confused. I think it was originally only wired between the white and black. I am not sure if I have to get some extra wire and connect the black and red to the light and the white to the fan? Extra wire is confusing.
the black is one switch leg and the red is the other switch leg connect black to fan and red to light and ground the green or bare wire it will work just fine and connect white to white neutral
Q: function of a fire-wire for backing up data
a firewire is just a port on your computer, mind you they are currently slightly faster then a usb. But what helps do a backup is the program you have on your computer, not the connection to the computer.
Q: When was the hot-wire anemometer invented? and who was it?
Sir Charles Wheatstone in 1843 modern anemometer use ultrasound hot wire sensors are used as mass air flow but did not find original usage! Guru
Q: Coming from my ceiling I have a black, a grey, 2 white, 2 bare and a red wire. Coming from my ceiling fan/light fixture is a green, black, black with a white stripe and a white wire. How exactly would I go about wiring this? It is a two switch setup without a remote.Thank you in advance.
Call the manufacturer about your ceiling fan. It may be designed to work with a light kit. I've done this myself. The grey and red sound like wiring that works with the light kit. The black, white, and green wires are hook to your house wire. (House wire is black, white, and bare (ground)).
Q: Wire 1 and wire 2 are made from the same metal. Wire 2 has a larger diameter than wire 1. The electric field strengths E1 and E2 are equal. A) Compare the values of the two current densities. Is J1 greater than, less, or equal to J2?B) Compare the values of the currents I1 and I2. Is I1 greater then, less or equal to I2?
The current will be more dense in the smaller wire. The value of the current is inversely proportional to the resistiance of the wire. Resistance = resistivity * length / Area since the wires are of identical material and length, the only thing left to vary is the cross-sectional area. Area is proportional to the square of the radius (diameter), so the current will be proportional to the square of the diameter. I2 is proportional to I1^2 I2 is larger than I1 .
Q: for california electrical code, am i limited to insert no more than one wire per knockout on a box ?
no. the number of wires in the box is restricted based on the volume of the box but the number of wires entering a knock out is restricted by the size of the conduit or the cable type connected to the knock out.
Q: I need thick floral wire and they keep saying things like 24 gauge 26 gauge 28 gauge.. like how would i know which one is thiickest if i'm buying it online.
This Site Might Help You. RE: What does gauge mean when buying floral wire? I need thick floral wire and they keep saying things like 24 gauge 26 gauge 28 gauge.. like how would i know which one is thiickest if i'm buying it online.
Q: My boat came with a rule 500 2-wire auto pump. I have an on/off switch at the console. My replacement has 3 wires. How do I connect the 3 wires and still use my on/off switch?
Good after I used to be within the navy, electrical energy was once three phase. There was once no original. Considering the fact that its is a pump, my recommendation is disconnecting the pump out of your load. Go ahead and wire up your pump inserting the 3 wires on any terminal. If the pump rotates in reverse, stop the power and swtch any 2 wires and you are good to move.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches