Galvanized Iron Wire Hot Dipped Galvanized wire Pvc Coated Wire
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 25 m.t.
- Supply Capability:
- 2500000 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification
1.Galvanized Iron Wire Hot Dipped Galvanized wire Pvc Coated Wire Description:
Galvanized Iron Wire has the characteristics of thick zinc coating, good corrosion resistance, firm zinc coating, etc.
Galvanized Iron Wire mainly used in construction, express way fencing, binding of flowers and wire mesh weaving. Galvanized iron wire according to manufacturing technique, it includes hot-dipped galvanized iron wire and electro galvanized iron wire. Mainly telecommunication equipment and materials, medical equipment and device, weaving of wire mesh, steel rope, and filtration mesh, high-pressure pipe, construction, arts and crafts.
2.Main Features of Galvanized Iron Wire Hot Dipped Galvanized wire Pvc Coated Wire :
• Use widely
• Corrosion- resistant
• Durable
• Practical use
• Beauty Surface
• Versatile
3. Galvanized Iron Wire Hot Dipped Galvanized wire Pvc Coated Wire Images
4.Galvanized Iron Wire Hot Dipped Galvanized wire Pvc Coated Wire Specification
Chemical composition | C | Mn | Si | S | P |
Guarantee value | ≤0.12 | 0.3~0.6 | ≤0.35 | ≤0.035 | ≤0.040 |
Test Item | Rm(MPa) | ReL(Mpa) | A(%) | KV2(J) | KV2(J) |
Guarantee value | ≥420 | ≥330 | ≥17 | -(normal temperature) | -(0°C) |
General result | 460~540 | ≥340 | 18~26 | 50~80 | ≥47 |
5.FAQ
We have organized several common questions for our clients,may help you sincerely:
①How about your Galvanized Iron Wire Hot Dipped Galvanized wire Pvc Coated Wire?
One of the most biggest manufacturer & supplier of wires and wire mesh,is a large-scale professional UAE Market Electric Galvanised Wire BWG 20 0.7mm Hot Dipped Galvnised Wire factory in China. Annually more than 10000 tons wires and wire mesh are exported to markets all over the world. Different kinds of wires and mesh are available according to customer’s requirements.
②What is your Technical Information of Galvanized Iron Wire Hot Dipped Galvanized wire Pvc Coated Wire?
1).Material: super carbon steel
2).Processing by drawing, hot-dip zinc-plating
3).Standard wire gauge from 8# to 24#
4).Thick zinc-coating layer
5).Super in corrosion resistance
6).Firm coating layer
7).Custom size available
10 to 15g Zinc Coating and 35kg Tensile Strength Iron Wire Electro Galvanized Iron Wire
③How long can we receive the product after payment?
In the purchase of Galvanized Iron Wire within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served。
Galvanized Iron Wire Hot Dipped Galvanized wire Pvc Coated Wire
Galvanized Iron Wire Hot Dipped Galvanized wire Pvc Coated Wire
- Q: I just installed a Unity Spotlight on my 2007 Chevy Impala. There's a 6 inch wire coming out of the handle. When I stripped the wire there is a few strands of copper wire. How do I wire up the light? There isn't a distinct positive or negative.
- I okorder /... check out literature for others, if this don't help.
- Q: the charger has three wires to put a male plug on and they are black white and green and they look like 12 gauge wires
- wire colors are green is ground the black and white wires are you load wires look at you 240 volt plug and determine which terminal is the ground this one is where the green wire goes the black and white wire go to other two terminals this should do it
- Q: I had gotten 5 commercial solar cells from siliconsolar. But, I need to know where could I get wires to connect to the solar cells, in order to harness the cells energy.
- Wire is wire. Use wire heavy enough to handle the current and good enough insulation to handle the outdoors conditions.
- Q: Peugeot Speedfight 2, How can i find out what colour wire is fuel? indicators? .. Would it all be shown on the wiring diagram?
- Why do no longer you get a volt meter verify the battery voltage with bike became off then commence it and re-verify the voltage if there's no substitute its the alternator, it may develop as much as 13- 13.5 The alternator on a scooter is the magneto its below the flywheel and there very high priced. you may get a multimeter for between a 5 -10 quid
- Q: Hi,I'm looking to change the outlets and the switch and light fixture in a bedroom of a home built in 1948. The outlets are original to the home I think. Will I have to fish ground wire throught to the panel box for my new receptacles? Or just install new 2 slot outlets?Why the different looking wires?Is the older wire copper with a silver colored coating to indicate being neutral or is this an old aluminum wire? The hot wire is red plastic coated and looks modern to me.
- it is normal for a house built in the late 40's --- it was thought, at that time, that the aluminum wiring was cost effective and the most up to date === it would be wise to pull new wire and that would be 12 gauge with a ground [[ two wires, a black
- Q: Just need a wiring diagram link that shows all wires and possibly steps on installing an aftermarket stereo.
- www.okorder /
- Q: Hello, I have a 4 year old Trane XR12 unit. Recently the compressor fan is noisy, and now stops when when under power after 5-10 min. The main fuses and breakers are fine, the fan spins freely when turned, the contactor pulls in fine, the dual capacitor checks out. But, the wiring of the capacitor does not match wire diagrams. Could this have caused the fan motor to prematurely fail?..............................Terminal: C red wire, FAN brown wire, HERM has both orange and purple. Schematic shows the purple wire should be with red wire on common C. The purple also leads to fan.
- Hi, I looked at the schematic on-line. If you still have the original fan motor in the unit then you are correct. The center terminal on the capacitor should have the red wire from the T1 terminal of the contactor, the red wire from the compressor, and the purple wire from the fan. The FAN terminal should have the brown wire from the fan. The HERM terminal should have the orange wire from the compressor. The black wire from the fan and the black/blue wire from the compressor should lead back to the T2 terminal of the contactor. Again, that is if the motor is the original motor. If it was replaced at some point in time, the wiring colors can change from manufacturer to manufacturer, in which case it's possible that the new motor is wired correctly. There should be a diagram on the motor to show you the correct wiring configuration.
- Q: Hi,I'm trying to install a ceiling light with a 3 wire configuration (white, black, ground) into a wire configuration of 4 wires (white, red, black, ground). This is configured for two on/off switches.So far, I have white to white, black to black, and ground to ground with the red capped off. This works with one switch perfectly, however when I hit the other switch, the circuit breaker blows.Please help, and thank you!
- A circuit consists of two conductors not counting the green/bare, but can have more than two. Also a circuit can branch off and energize other things. Thus you have branch circuits. The ceiling box fan probably is a branch circuit consisting of two or three maybe four conductors i.e., black, red, white and green/bare. A ceiling fan will pull a load/current of usually 2 amps but can be a lot more. A 60watt incandescent light bulb pulls 1/6 of an amp, or 4 60watt bulbs is around 2amps. By and far the amount is very low considering most general lighting circuits can handle up to 20amps without any problems.
- Q: I just tore my old shed down, that was wired for electrical. though I never used power out there There is size 10 wiring (two wires), running from the house to where my shed was. I then bought a Tough Shed from The Home Depot and put it where my old shed was. While working on wiring my new shed for electricity, I turned power off to the entire house.I am trying to install power to the shed and I spliced the size 10 wires to size 14 (three cable, includes a ground) which I have connect to an electrical outlet in the shed, but once I turn the main power box back on, the circuit that runs power to the shed keeps tripping off. Am I missing something here?Thanks
- GET A PRO,...................or atleast someone that knows enough about electricity not to make a death - trap
- Q: what wires connect from the vehicle to the a/f sensor
- Why do u want to know what wires go to the sensor? If you have a code for the a/f sensor..99 % of the time it is an open in the sensor itself. On rare occasion there are others like a chewed wire by a rodent. But I would just recommend replacing the a/f sensor. And i u were to follow the wires from the male connector they would lead you to a big wire harness that basically just all ends up at the ECU. Just in case u wanted to know.
Send your message to us
Galvanized Iron Wire Hot Dipped Galvanized wire Pvc Coated Wire
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 25 m.t.
- Supply Capability:
- 2500000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches