• Cable with Transducer Cable with Transducer Cable with Transducer System 1
  • Cable with Transducer Cable with Transducer Cable with Transducer System 2
Cable with Transducer Cable with Transducer Cable with Transducer

Cable with Transducer Cable with Transducer Cable with Transducer

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Produced with the reference to standards of GB/T12706.1-2002 "rated voltage 1 KV (Um = 1.2kv) to 35 kv (Um = 40.5kv) crowded pack power cable insulation and Annex 1: rated voltage 1 kv (Um = 1.2kv) and 3 kv ( Um = 3.6kv) cable " It applies to all kinds of cable connecting of equipment with transducer such as frequency power, and convertible motor. With the three-phase symmetrical structure, the cable can increase the capacity of resisting electromagnetic interference. The cable has a variety of shielding structures. Vertical package with aluminum-plastic composites can effectively shield cable itself from outside electromagnetic interference, thereby enhancing the efficiency of equipment with transducer. The shielding structures of Copper belt and brass wires shield the electromagnetic wave produced by the cable to prevent leak, protecting other equipment from interference and the environment from the electromagnetic pollution.


main speciality

◆ Max. permissible continuous temperature: PVC: 70℃; XLPE: 90℃.
◆ Max. short-circuit temperature of the conductor shall not exceed: PVC : 160℃; XLPE:250℃.
◆ The installation temperature should not below 0℃ .
◆  The bending radius of cables are recommend as follows: the soft  conductor is not less than 10 times the diameter of cables; others is  not less than 15 times the diameter of cables.


type

name

non armoured

Steel tape armoured

BPVPV

 -----

PVC insulated copper wire braid shield cable with transducer

ZR-BPVPV

----

PVC insulated copper wire braid shield fire-proof cable with transducer

ZR-DL-BPVPV

----

PVC insulated copper wire braid shield low smoke and low halide content fire-proof cable with transducer

BPVPVP3

----

PVC insulated copper wire braid shield AL-plastic compound band shield cable with transducer

ZR- BPVPVP3

----

PVC insulated copper wire braid shield AL-plastic compound band shield fire-proof cable with transducer

ZR- DL-BPVPVP3

----

PVC  insulated copper wire braid AL-plastic compound band shield low smoke  and low halide content fire-proof cable with transducer

BPVP1VP2

BPVP1VP2-22

PVC insulated copper wire circle copper tape shield cable with transducer

ZR-BPVP1VP2

ZR- BPVP1VP2-22

PVC insulated copper wire circle copper tape shield flame-resistant cable with transducer

ZR-DL- BPVP1VP2

ZR-DL-BPVP1VP2-22

PVC insulated copper wire circle copper tape shield low smoke and low halide content flame-resistant cable with transducer

BPVP1VP3

BPVP1VP3-22

PVC insulated copper wire circle AL-plastic complex tape shield cable with transducer

ZR- BPVP1VP3

ZR- BPVP1VP3-22

PVC insulated copper wire circle AL-plastic complex tape shield flame-resistant cable with transducer

ZR-DL- BPVP1VP3

ZR-DL- BPVP1VP3-22

PVC  insulated copper wire circle AL-plastic complex tape shield low smoke  and low halide content flame-resistant cable with transducer

BPVP2V

BPVP2V22

PVC insulated copper tape shield cable with transducer

ZR- BPVP2V

ZR- BPVP2V22

PVC insulated copper tape shield flame-resistant cable with transducer

ZR-DL- BPVP2V

ZR-DL- BPVP2V22

PVC insulated copper tape shield low smoke and low halide content flame-resistant cable with transducer

BPYJPV

-----

XLPE insulated copper wire braid shield cable with transducer

ZR-BPYJPV

-----

XLPE insulated copper wire braid shield flame-resistant cable with transducer

ZR-DL-BPYJPE

-----

XLPE insulated copper wire braid shield low smoke and low halide content flame-resistant cable with transducer

BPYJPVP3

 -----

XLPE insulated copper wire braid AL-plastic complex tape shield cable with transducer

ZR- BPYJPVP3

 -----

XLPE insulated copper wire braid AL-plastic complex tape shield flame-resistant cable with transducer

ZR-WL-BPYJPVP3

 -----

XLPE  insulated copper wire braid AL-plastic complex tape shield low smoke  and low halide content flame-resistant cable with transducer

BPYJP1VP2

BPYJP1VP2-22

XLPE insulated copper wire circle copper tape shield cable with transducer

ZR-BPYJP1VP2

ZR-BPYJP1VP2-22

XLPE insulated copper wire circle copper tape shield flame-resistant cable with transducer

ZR-WL-BPYJP1VP2

ZR-WL- BPYJP1VP2-22

XLPE insulated copper wire circle copper tape shield low smoke and low halide content flame-resistant cable with transducer

BPYJP1VP3

BPYJP1VP3-22

XLPE insulated copper wire circle AL-plastic complex tape shield cable with transducer

ZR-BPYJP1VP3

ZR- BPYJP1VP3-22

XLPE insulated copper wire circle AL-plastic complex tape shield flame-resistant cable with transducer

ZR-WL-BPYJP1EP3

ZR-WL- BPYJP1VP3-22

XLPE insulated copper wire circle AL-plastic complex tape shield low smoke and low halide flame-resistant cable with transducer

BPYJP2V

BPYJP2V22

XLPE insulated copper tape shield cable with transducer

ZR-BPYJP2V

ZR- BPYJP2V22

XPLE insulated copper tape shield flame-resistant cable with transducer

ZR-WL-BPYJP2E

ZR-WL- BPYJP2E22

XLPE insulated copper tape shiled low smoke and low halide flame-resistant cable with transducer


Q: My 4 gauge power cable is hooked up to the battery's positive terminal and the other end to my amplifier's terminal. Is it safe to accidentally touch the ring terminal (end) of this power cable? I won't feel any electrical shock or anything will I?
Anything below 30 amps DC will not hurt ya. However,.. you CAN get shocked by DC voltage. -its when you get up around 75 amps that will feel hot like a fire heated wire. At around 150 amps it still won't shock you like AC current but will make you pee on yourself.
Q: I just bought a new motherboard and it had a 24 pin power thingy, my power supply was only a 20 pin. After looking at my manual it said I was able to do that if I aligned them a specific way. After that PC turns on, the lights turn on, hard drives turn on, and everything else. the thing is the screen stays black and says no signal.I was looking on the motherboard and there is a 4 pin ATX12V1, but there is no such cable that comes out of my power supply. I think the reason the screen stays blank is because it said that was used to power the CPU. What can I do since I do not have a ATX12V1 cable that connects to my motherboard?The only cables that come out of my pwr supply are for the IDE and floppy.
You need a new power supply. Make sure it's 24 pin and has enough wattage and amperage on the +12v rail to power your system.
Q: is it possible to run a 2-wire AC power cable (2x2.5mm2 or thicker) from the telephone junction box to the inside of the house instead of using an ordinary thin phone cable? will that affect the voice quality or maybe an ADSL setup? the distance is approximately 50 meters.thanks a lot.
Two conductors are two conductors, unless there are high-frequency issues. In this case it appears that if you are replacing parallel (not twisted) wires with another set of at least equal thickness, you should be okay. Since ADSL is used on parallel wires, without twisting them, the frequencies conducted should not present problems.
Q: The power cable is selected according to the cable current ()
PVC pipe. Iron pipe, trunking, bridge, hose, and so on. The The PVC pipe, trunking generally the most common, used in the kind of request is not very strict, not much bit line. Capital is not high, low cost, iron pipe bridge is mainly used in fire strict buildings, shopping malls, high cost, security, line points and more use of bridge hose used in the line out of the floor to the desktop section. Nice point of the ceiling. Overhead floor, are suitable for placement is not comprehensive, personal experience
Q: Excuse me, what is the difference between submarine power cables and general buried power cables? What is the difference between the calculated current carrying capacity of the submarine power cable and the general calculation of the current carrying capacity of the cable? More
1 TV inside the 400V filter capacitor damage 2 audio and video cable connection is not good or poor quality 3 you put the TV volume dots, set-top box volume can be improved
Q: then directly to the capacitor. or should the resistor be in the middle of the power cable.
it truly is No resistor get a. try gentle betwen the cap and power wire once gentle dies down thoroughly placed wire and tighten. Ive. carried out thks no challenge possibly small spark even if it truly is gonna ensue
Q: i cant seem to find a place to put my power cable to the inner part of the car.i dont seem to find a decent place to drill a hole to or the firewall i think its what itscalled, im using a buick regal 1992.... i was thinking of putting it through the door, is that safe?is it done sometimes or not recommended at all?
i okorder /
Q: my sub came loose and started sliding around in my boot until the power cable got ripped out of the amp while i was driving at it was on. When i tried putting the power back in it just blew the fuses, so i bought some more, and they blew as soon as they went in as well, and one of the bits of metal melted putting one it! strathfield said its 45 for an inspection, plus the cost of fixing it. any ideas whats wrong with it and if i can fix it myself??cheers.
You can repair this if you already know what you are doing. Each wire in the cable terminates on a specific terminal. (A power cable can be expected to have 2 wires, a red and a black for pos12v and neg12v respectively. Reverse these wires even for a moment and wave your amp goodbye, unless there is protection built in if you're lucky) So ... Do you know all the repair proceedures? Do you know what wire belongs to what terminal? (No trial and error allowed here) If you have any doubt about doing this right first time then you are unable to fix it your self, and it would be better to take it to the experts and pay for repair.
Q: I've got 1/0 gauge wiring and if i run this along my rear deck quot;speaker wireswill this cause noise?im not talking about the RCA cables.
if its for a short distance it shouldnt, if its like the whole length of the car its possible
Q: I want to order a small 100 watt amp and needed to know if it can get powered by the head unit by connecting it with the rca cables.. thanks..
The RCA cables do not supply power to the amplifier; they just carry the audio signal from the head unit to the amp. Your amplifier, regardless of its power rating, will need power and ground connections in addition to the RCA and remote outputs from the head unit.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords