• 8-22 Gauge Spool Galvanized Steel Wire with High Resistance System 1
  • 8-22 Gauge Spool Galvanized Steel Wire with High Resistance System 2
  • 8-22 Gauge Spool Galvanized Steel Wire with High Resistance System 3
8-22 Gauge Spool Galvanized Steel Wire with High Resistance

8-22 Gauge Spool Galvanized Steel Wire with High Resistance

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT or LC
Min Order Qty:
100 roll
Supply Capability:
10000 roll/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

8-22 Gauge Spool Galvanized Steel Wire with High Resistance

 

1.Structure of 8-22 Gauge Spool Galvanized Steel Wire with High Resistance Description

‍‍Spool Galvanized Steel Wire is made with choice mild steel, through wire drawing, wire galvanizing and other processes. Galvanized iron wire has the characteristics of thick zinc coating, good corrosion resistance, firm zinc coating, etc‍. 

Spool Galvanized Steel Wire can be supplied in the form of coil wire, spool wire or further processed into straightened cut wire or U type wire. It is mainly used in construction, express way fencing, binding of flowers and wire mesh weaving.‍

 

2. Main Features of 8-22 Gauge Spool Galvanized Steel Wire with High Resistance

• Antirust

• Shiny silvery color

• High strength

• Durable

• Versatile

• Good visual effect

 

3. 8-22 Gauge Spool Galvanized Steel Wire with High Resistance Image

 

4. 8-22 Gauge Spool Galvanized Steel Wire with High Resistance Specification

8-22 Gauge Spool Galvanized Steel Wire with High Resistance

5. FAQ

We have organized several common questions for our clientsmay help you sincerely

   How about your products

‍One of the most biggest manufacturer & supplier of wires and wire meshis a large-scale professional Spool Galvanized Steel Wire with High Resistance

 

factory in China. Annually more than 10000 tons wires and wire mesh are exported to markets all over the world.Different kinds of wires and mesh are available according to customers requirements.‍

 

How to guarantee the quality of the products

We have established the international advanced quality management systemevery link from raw material to final product we have strict quality testOur company has good marketing network and abundant operation experience. Galvanized Iron Wire are sold to all parts of the country, at the same time, exported to Southeast Asia,The management theory is based on sincerity, keeping forging ahead. We have accumulated a whole set of marketing experience, having already become a local leader engaged in steel products.

 

How long can we receive the product after purchase?

In the purchase of Spool Galvanized Steel Wire with High Resistance within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served.

 

 



Q:A toy of 2.8N is suspended by two wires from a horizontal beam.One wire is 40 degrees to the vertical of the beam.The other is at 60 degrees to the beam.What is the tension in each wire?
The horizontal tensions in the two wires must be equal. The vertical tensions must add to 2.8N. Let the tension in the wires be t1 and t2. t1 * sin(40) <== horizontal tension in wire 1 t1 * cos(40) <== vertical tension in wire 1 t2 * sin(60) <== vertical tension in wire 2 t2 * cos(60) <== horizontal tension in wire 2 t1^2 = (horizontal tension in wire 1)^2 + (vertical tension in wire 1)^2 t2^2 = (horizontal tension in wire 2)^2 + (vertical tension in wire 2)^2
Q:Replaced the old fan in my bathroom (about 10 years old) with a new fan. Trouble is this. The fan and light each work on a seperate bathroom switch. I have two spots to install the wire on the new bathroom fan/light. One for the fan and one for the ligth. However, the wiring has one white, one black, one red and the ground. Anyone know what the red is? Can I just cap it off? According the bathroom fan wiring it says something about connecting red to blue. I am slighty confused. I think it was originally only wired between the white and black. I am not sure if I have to get some extra wire and connect the black and red to the light and the white to the fan? Extra wire is confusing.
the black is one switch leg and the red is the other switch leg connect black to fan and red to light and ground the green or bare wire it will work just fine and connect white to white neutral
Q:Anyone know which wire behind the navigation unit is the brake wire? I THINK it's pink, but there are multiple pink wires behind the navigation unit.Thoughts?
Are okorder 's outlander section for a posts on how to disable.
Q:I have a 98 oldsmobile intrigue. Stock radio was taken out a while ago so all there is are wire hanging out. I don't know what I need, a wire connector or wire harness. Honestly don't know what's what. Also need to know how to use the wire connector/harness.and what goes to what
those wires you see are factory wiring for the factory radio. if your putting a aftermarket radio in it go to radio shack and ask for plug-ins for your car.with those plug-in all you do is hook the wiring from your aftermarket radio to them then plug them into the factory harness.
Q:My dad is trying to wire a electric cook top...it has three wires (black, red, and copper). His junction box has four wires (black, red, white and copper). He first wired the black to black, red to red and copper to copper, he capped the white wire in the junction box. The cook top did not work. Then he connected the white wire with the two copper wires, and the cook top now works. So the question is will this connection work or will it cause a problem? And if it causes a problem what can he do to resolve it?
Hi There, This what I would do. The black and red wires from the cooktop are fine and can be connected to the black and red wires in the junction box. Check the copper wire from the stove and see where it is connected. It is probably a neutral wire used to supply 120 volts for a clock, lights or other control function. If that is the case I would exchange it for a properly sized insulated white wire. This white wire can be connected to the white wire in the junction box. Then: Connect the copper wire to a metal part of the cooktop to use as a ground wire. This wire can then be connected to the copper wire in the junction box. This would be a typical modern 4-wire 240 volt setup. Hope this helps, Al
Q:im trying to install a cd player i need to know where i can hook up power(red) , constant(yellow), and my amp seems to take alot for remote wire so i need a good source for it too i also have a eq to power but dont know if it will work with the same source as the radio
You can get the constant and accessory wires at the ignition harness. If you want colors you'll have to specify a year, make, and model.
Q:i Have a problem with my xeno portable dvd player..the ribbon wire inside is damaged..can somebody tell me where to buy a ribbon wire?
Electronic parts stores carry ribbon wires, but there are many different kinds of ribbon wires, and they would have to look at the wires in the dvd player to know what kind you need. The biggest problem with the wires is connecting them to the circuit boards. An electronics repair shop might have a piece of ribbon wire they can adapt to fit your player. .
Q:Why is thin strand wire better for powering car audio?
Hi welt needs to be multi stranded at least 8 awg in diameter as it is flexible and more flexible than a solid wire as work wire back and forth hardens copper wire and it eventually will break. using a flexible wire reduces the possibility of a breakage.
Q:so there are 3 different wires coming into the switch. 1 black wire and 2 white wires going to the attic fan (i assume one for high and one for low). the power seems to be coming from the black wire which has inside of it, one white wire (neutral) one black wire (hot) and one bare wire (ground).. the same for the 2 white wires. the switch goes up (^) for high and down (v) for low and has 3 places to attach the wires to. the top, the bottom and the middle.. can someone tell me how to wire this damn thing?
I think you are describing NM cables(Romex). What you have is: 1 black romex with a hot(black) a neutral(white) and a bare ground. and 2 white romexs with a black, white, bare each. right so far? What you probably have is the hot and neutral going to the switch j-box (black romex) and the 2 white romexs go from the switch to the fan j-box. I think I need more info. Do you have a test meter? Are you sure the black romex is the Hot and Neutral? When the wires are disconnected are there other things that don't have power to them? Did you undo the neutral splice? If you could send this info I think I can walk you thru it.
Q:I bought a new ceiling light and wired it myself. But I cheated by just copying the wiring from the old bracket into the new one. I want to do the other ceiling lights in my home. Supplied with the lights I am using is a 3 - way bracket (sori if terminology is wrong). Anyway the old bracket I copied was 4 way. My lights are wired from the mains supply with 3 live wires, 3 neutrals, and 3 positives. The light unit only has one live/neutral/positive wire. What do I do with the extra mains supply wires? I hope I have made myself clear as I even I am confused. Many thanks.
Sounds like you have extra wires that are feeding other outlets or lights.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords