YL-2BEA shaft transmit water ring vacuum pump
- Ref Price:
-
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
Add to My Favorites
Follow us:
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
2BEA pump and compressor are designed according `to internationally advanced technology. It is widely used in pumping pure,water-fast, and innocuous gas, so that vacuum and pressure is produced in the sealed container.It is also used in pumping caustic, flammable, and explosive gas, supposed we change the material, structure, and introducean explosion-proof electromotor.Single grade adoption, availability of segregator, existence of gas entrance from different directions, addition of drain tap maintaining windown on the surthce, make it simple, effective, reliable and easy to maintain. It is widely used in Papermaking, Chemical lndustery, Petrification Industry, Light Industry, Medicine Production, Foodstuff, Metallurgy, Building Materials, Coal Washing, Chemicals etc.Items:2BEA-103~2BEA-705/2BEC-42~2BEC-72,Motor power 11~630KW,extract capacity 290~27000m3/h,Limit vacuum -0.097~-0.084MPa。
List of performance
Type of pump | Speed r/min | Shaft power(Max) Kw | Limit vacuum hpa | Gasm m3/h | Weight kg |
2BEA103-0 | 1450 | 8.2 | 33 | 340 | 125 |
1750 | 11.2 | 410 |
2BEA153-0 | 1450 | 13.5 | 33 | 600 | 190 |
1750 | 19.5 | 700 |
2BEA203-0 | 980 | 29.5 | 33 | 1120 | 410 |
1100 | 35 | 1240 |
2BEA253-0 | 660 | 45 | 33 | 2100 | 890 |
740 | 54 | 2400 |
2BEA303-0 | 472 | 50 | 33 | 2560 | 1400 |
530 | 57.5 | 2850 |
590 | 65 | 3200 |
660 | 79 | 3600 |
740 | 99 | 4000 |
2BEA353-0 | 420 | 74 | 33 | 3700 | 2000 |
472 | 84 | 4200 |
500 | 90 | 4480 |
530 | 100 | 4720 |
590 | 120 | 5300 |
2BEA403-0 | 372 | 110 | 33 | 5680 | 3300 |
420 | 130 | 6280 |
472 | 160 | 7350 |
530 | 203 | 8120 |
2BEA405-1 | 330 | 100 | 160 | 5950 | 3400 |
372 | 118 | 6750 |
420 | 140 | 7550 |
472 | 170 | 8300 |
2BEA505-1 | 298 | 150 | 160 | 8800 | 5100 |
330 | 172 | 9750 |
372 | 205 | 10750 |
420 | 250 | 11820 |
2BEA605-1 | 236 | 188 | 160 | 11500 | 7900 |
266 | 220 | 13000 |
298 | 262 | 14900 |
330 | 310 | 15700 |
2BEA705-1 | 210 | 285 | 160 | 17500 | 11500 |
236 | 335 | 19700 |
266 | 405 | 21750 |
298 | 490 | 23850 |
- Q: Why does the centrifugal pump close the pressure to start?
- The flow is zero (i.e. off dead) minimum, the highest lift power; with the outlet valve opening increases, flow increases, the lift, power and efficiency are increased, the maximum value (usually in the vicinity of the highest rated flow point)
- Q: What is a water pump coupling device?
- The automatic coupling device of the water pump coupling device has compact structure and small occupation area. The sump pump works because it is submergedThe utility model can be directly installed in a sewage pool, and no special pump house is needed to install a pump and a machine, thereby saving large amounts of land and infrastructure expenses
- Q: What is the name of the day pump and ground pump? Specific introduction
- PumpGround pumps are used very frequently in many large basements, because they have no boom, so they need to be taken over manually. In addition to the site, for those days to pump the high-rise buildings, such as 200 meters or 200 meters altitude, can also take over to transport concrete by pump, but the premise is to have enough power to pump concrete will hit above the height and the length of nozzle can reach the height of the floor.Thus, the day pump and ground pump have their respective advantages. The pump is easy to use, but the ground pump can make up for the height that the pump can not reach. At the same time, the price is relatively cheap, so users can choose the corresponding concrete pump when they are in use.
- Q: How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
- For example: water storage is relatively small, it needs to reduce the temperature of the heat exchanger. If the tank is relatively large, it does not need cooling water circulation pump again when the temperature is very low, there is no need to heat exchanger. So you need to ask how much water this is not OK.In a soda separator problem:
- Q: What's the pump? Where can I use it?
- Pump can usually be divided into three types of displacement pumps, power pumps and other types of pumps according to the principle of operation. In addition to classification according to the working principle, it can be classified and named according to other methods.
- Q: How to install, operate and maintain the pipeline booster pump?
- When the pump leaks, check it immediately to prevent leakage. If it leaks with the motor connection, replace the mechanical seal. Check that the power is connected. Is the supply voltage consistent with the operating voltage of the pump?. If the above a and B are normal, please remove the pump, open the pump cover, remove the foreign body in the pump, and then pump the lid on, and then tighten it to normal.No water pump, pump installed in the tap water pipeline, such as tap water level in the pump impeller on the plane (horizontal installation) or center line (vertical) below, you should turn off the power supply, to tap water level rise more than the impeller plane or the center line, connected to the power supply, to avoid mechanical damage (automatic no need to turn off the electric type). When the pump used in pumping wells, please check whether the water inlet pipe leak; pump cavity storage is not enough, should be filled with water, whether the suction process is too high, proper adjustment. Check whether the inlet and outlet diameter is too small or blocked. Automatic type after a period of time, there may be automatic failure phenomenon, mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging, can be re used.
- Q: Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
- 3. efficiencyVolume efficiency, for hydraulic pumps, is the ratio of actual flow to theoretical flow. A hydraulic motor is the ratio of its theoretical flow to its actual flow.Mechanical efficiency, for hydraulic pumps, refers to the ratio of theoretical torque to actual input torque. The actual output torque of the hydraulic motor is theoretical torque to overcome the torque after friction, so the mechanical efficiency is the ratio of the actual output torque to the theoretical torque.
- Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
- The operation rules of centrifugal pump strictly required to close the outlet valve before the shutdown, boot and then slowly open the outlet valve, regulating pipeline pressure and current range. The reason is: the centrifugal pump in the startup process in order to avoid large starting current caused by electrical faults, such as circuit breaker tripping,
- Q: The working principle of magnetic pump
- Control of cooling fluid flowThe pump is running, you must use a small amount of liquid in the magnetic separation between the rotor and the casing annulus area and sliding friction bearings for flushing cooling. The cooling liquid flow pump design flow is usually 2%-3%, the annular area between the magnetic rotor and sleeve of eddy current generated because of high heat. When the cooling and lubrication the liquid is not enough or poor flushing holes to plug, will result in permanent magnet medium temperature is higher than the operating temperature of the inner magnetic rotor gradually loses magnetism, the magnetic actuator failure. When the medium is water or water-based liquid, can make the annulus area temperature maintained at 3-5 DEG C; when the medium or hydrocarbon oil that can make the annulus area temperature maintained at 5-8 degrees.
- Q: Filter backwash pump for what use, what is the principle of work ah?
- Regeneration of the filter medium is required to regain the filtration capacity of the medium. The regeneration process is mainly accomplished by the backwashing pump (the backwash pump is not a special pump, referring to the pump for the completion of the process). The working principle is through the cleaning liquid from the downstream of the filter into the backwash pump (alkali, acid and water), reverse flushing filter medium, cleaning liquid discharged from the upstream, this process can be attached to the dielectric surface and internal impurities washed away.