Product overview
Fourth generation KQL, KQW series single-stage single-suction centrifugal pump, is my company USES the best hydraulic model, and according to the working condition of all types of users under different conditions of use carefully designed. This series of products, compact structure, reasonable, stable and reliable operation; Configuration of special machine sealing structure, improve the operating environment, extend the service life; High efficiency and energy saving, low operating cost, saving management costs; Cover an area of an area small, save construction investment, favored by the market.
Application field
The central heating system of circulating water; Refrigeration, cooling circulating water of air conditioning system
Water treatment, sanitary water; Indoor living water supply, domestic hot water system
Water supply, water irrigation system; Flushing system with water
Product features
1, the pump and motor directly connected, pump shaft completely concentric, small vibration noise is low; Special structural configuration of bearing, impeller cantilever short, operation is stable and reliable
2, the use of forced circulation should not be restricted to the special structure of configuration of mechanical seal, improve its running environment, prolong service life
3, advanced pump chamber and the impeller design, make the pump has the superiority of hydraulic characteristics, ensure the pump efficiency and energy saving, low running cost, cut down the cost of operation management by 50% to 70%
4, unique installation structure greatly narrowed the pump cover an area of an area small, save construction investment from 40% to 60%
5, stainless steel shaft, never rust, guarantee the mating part tear open outfit is simple, reliable mechanical seal bellows seal, maintenance-free, easy to maintain。
The working conditions
Traffic: 1.8 ~ 2000m3 / h head: 127 m or less
Transfer rate: 2900 r/min, 1480 r/min, 980 r/min
Medium temperature: - 10 ~ 80 ℃ ambient temperature: maximum + 40 ℃
Maximum working pressure (pressure) :
125 diameter (2 extreme speed) and below 125 diameter: 1.6 Mpa
125 diameter (4 pole speed) and 150 ~ 200 diameter: 1.2 Mpa
250 caliber and more than 250 diameter: 1.0 Mpa
- Q: How can the submersible pump level meter be connected?
- The company actively introduce international advanced production equipment and production technology, with its strong technical force, perfect equipment conditions and rich manufacturing practice, constantly development and improvement of pump products, according to the needs of users of innovative products, stable performance, excellent quality, many products export part countries and regions
- Q: Variable flow pumps are variable pumps
- Variable input speed, the pump out of the flow is variable, it can not be said that it is variable pump.In a word。 A variable pump is a variable displacement pump.
- Q: What are the causes of pump shock?
- Troubleshooting cause1. bearing damage, replace new bearings2., coupling pin, bolt damage, rubber column or metal bolt wear, change
- Q: The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
- High speed rotating impeller blade drives the liquid to rotate, and the liquid is thrown out so as to achieve the purpose of conveying. There are many medium for transportation, such as oil, water, chemicals and so on. The pump shaft and the motor shaft are of the same shaft, the pump and the motor are made into an integral body and immersed in water. The medium of transportation is water.
- Q: Concrete pump 125 pipe wall thickness
- Currently mainly divided into gate valve, concrete pump and S valve concrete pump. Another is a pump consisting of a pump body mounted on an automobile chassis and fitted with retractable or bent cloth poles
- Q: I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
- (8) check the suitability of the foundation and whether the size of the foundation corresponds to the size of the pump.(9) find the position of positive pump and motor, pump set and anchor bolt and the inlet and outlet flanges, to ensure that the flange torque of the pump conforms to the standard. Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition. It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
- Q: Is the centrifugal pump large or small?
- Centrifugal pump, the smaller the better the cavitation.1, centrifugal pump cavitation less, anti cavitation performance is better, the pump cavitation is called the necessary cavitation margin or pump inlet dynamic pressure drop, the smaller the better. Generally speaking, the pump cavitation is the need for cavitation, the pump inlet pipe said effective cavitation margin, that is, the device cavitation margin. For a given pump, at a given speed and flow rate required NPSH is called pump necessary NPSH, also called NPSH, is required to achieve the performance parameters of the pump cavitation, the internal flow and the centrifugal pump is composed of pump head itself, its physical meaning is that liquid drop in pump inlet pressure part degree, is to guarantee the pump cavitation does not occur, with surplus energy exceeds the vaporization pressure head at the inlet of the pump unit weight of liquid. The cavitation must be independent of the device parameters. It is only related to the parameters of the inlet of the pump. These parameters are determined by the geometric parameters at a given speed and flow.
- Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
- What is straight pump and non direct pump? Direct coupled pump shaft and the motor shaft is directly coupled with the coupling and non direct coupled pump: pump shaft and motor shaft through the belt pulley, V-belt connection or other forms of transmission. What is the difference in the structure: the direct coupled pump has the advantages of compact structure, simple installation, but the relatively small power; non direct coupled pump: pump and motor is independent, the two transfer torque through the belt, the structure is relatively large, complex installation, general power is relatively large.
- Q: What is the distance between the pump and the wall?
- What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.
- Q: What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
- Centrifuges are generally used to classify liquids of different densities in liquids.