Design |
Overview of technical data
Type of impeller | Axial; Open;Propeller |
Type of installation | Close- coupled |
Maximum drive rating | 700 kW |
Impeller material (EN standard) | 1. 4517;AL-BRONZE |
Type of bearing | Rolling element bearings |
Drive frequency | 50 Hz / 60 Hz |
Maximum speed of rotation | 1. 750 1/min |
Maximum flow rate | 25. 200 m³/h |
Casing material (EN standard) | JL 1030 |
No. of impeller entries | Single entry |
Casing material | Cast iron |
Minimum flow rate | 360 m³/h |
Suction characteristics | Non- priming |
Drive voltage | Low voltage |
eClass assignment | 36410101; 36410106 |
Pump set location | 00 |
Explosion protection | ATEX II 2G T3 |
Max. permissible fluid temperature | 40 ****** |
Free passage | 255 mm |
Main applications | Energy; Mining / Dredges;Water;Waste water / sewage |
Type of installation | Stationary |
Type of casing | Tubular casing |
Type of lubrication | Grease lubrication |
Type of drive | Electric motor |
Installation position | Vertical |
Shaft material (EN standard) | 1. 4057.05;1.4021.05 |
Type of coupling | None |
Shaft seal type | Mechanical seal |
Drive | Electric motor |
Maximum head | 12, 00 m |
Minimum head | 0, 80 m |
Nozzle position | In- line |
Casing partition | Radially split |
Connection to power supply | 380 V, 400 V, 690 V, 3~ |
- Q:What are the constant pressure pumps?
- CatalogBooster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principlefunctionMechanical installationMechanical selection of booster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principle
- Q:Household automatic booster pump, how much pressure to work automatically, the water pressure and how many kilograms?
- Start the pump. Water pressure depends on how large you buy the pump, generally small, mostly 10-15 meters hydraulic pressure, about 200 of the price.
- Q:Why should I pump the pump before starting the centrifugal pump?
- 1., if it is backward flow, it is not pumping;2., if the pump is installed underwater (such as submersible sewage pump), it is not pumping;3. pump is for installation in the form of suction. If no diversion irrigation pump, then the pump is full of air quality, air density is less than water, the pump will not be inside the gas out, the pump pressure will not be far less than the atmospheric pressure, the water will not be pressed into the pump to pump through irrigation formed inside the closed environment, the pump will start water out will cause local vacuum, entrance external water pressure into the pump is in inside and outside differential pressure, complete water movement. (vacuum water diversion is directly through the vacuum pump pumping the air in the pump, resulting in internal and external pressure difference, the external water pressure in the internal and external pressure is press into the inlet of the pump. The principle is the same as the pump. A standard atmosphere of =10m water column.)
- Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- Such as a large pressure of about 10m or about 0.1MPa} because the most unfavorable point fire hydrant requires more than 0.07MPa (7m) and 0.5MPa (50m) is not greater than the pressure, so unless the pump is located in the 50m Valley is still lower than the garage, or add to the valve (or the use of fire hydrant decompression) otherwise, it is 120m lift pump
- Q:What is the difference between the ground pump and the pump in the commercial concrete?
- What you should say here is the concrete pump.Ground pump: the pump will be placed in a position on the site, the pipeline will be sent to the construction of concrete surface,
- Q:What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
- The 2BV vacuum pump belongs to the machine pump coaxial type direct connection design. It saves space and is easy to install;The use of mechanical seals as standard configuration eliminates leakage and easy maintenance;Smooth running, low noise to 62 decibels;
- Q:What does electromechanical vector pump mean?
- It is a close set of mechanical and microelectronic technology. It adopts dual control center mode to control, and has a new water pump with logic control center and IPC control center.
- Q:I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
- The pressure loss is borne by the valve. Constant pressure pumps generally do not export direct load, unless you need this load response is very fast, then the maximum displacement of the pump work, so as to ensure the rapid response of the load.
- Q:Is the flow meter in front of the pump or after the pump?
- After the pump, the reasons are as follows, before the pump, you pump fluid through the pump will produce negative pressure in front of the pump, negative pressure on the flow of the life of the impact, the pump will not, Suzhou first Chi meter
- Q:Working principle and diagram of axial piston pump with pressure compensation variable
- Adjust the flow characteristics, the first limit screw to the top, according to the flow and pressure changes in the required range, adjusting the spring set, the initial flow pressure began to change to meet the requirements, then the limit screw to the ultimate pressure when the flow is no longer changed, the relationship between flow and pressure the changes are determined by the pump itself.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Submersible motor pump Amacan P
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 1 pc/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
New products
Hot products
Hot Searches
Related keywords