The second-generation YW(P) series under-liquid sewage pump is a new and patented product latest developed by our company,specially for transporting various sewages under harsh working conditions and made by way of, on the basis of the existing firstgeneration product, absorbing the advanced know-how both at home and abroad and usingWQ series submersible sewage pump's hydraulic model of the most excellent performance at present.
YW series under-liquid sewage pump not only has the all superior performances of theWQ series submersible sewage pump but also greatly opens out the applocable working conditions and fields of use of the latter due to its unique form of installation.
Suitable for steel works, power plant, coal works, mine, hospital,municipal works, chemical industry, medicine, building,hotel, sea-water suction and drainage etc. trades to transport the
industrial sewage with grains and fibres, the city's lovong sewageor rain water and pure water, and also for some flow processesof chemical industry.
The medium temperature not over 50℃ ;
The medium density less than1.2 10 kg/m; need a notice at
order for over than 1.2 10 kg/m ;
The medium's PH valve between 5-11.
- Q: Troubleshooting of diaphragm pump
- The troubleshooting guide for diaphragm pumps, when encountered in one or more of the following situations, this information can be used as a guide to help you develop maintenance measures.As shown below, some of the abnormal operating conditions described in this guide are: A) fast circulation / low flow B) no cycle / slow cycle / irregular cycle C) leakage D) noise E) component rupture
- Q: What are the functions of a disposable infusion pump?
- When the transfusion is too slow, the dosage may not be enough, or the infusion time is prolonged unnecessarily, the treatment is affected, and unnecessary burden is added to the patient and the nursing work. In routine clinical infusion, the infusion of hanging bottle is generally used, and the speed of infusion is controlled by the use of a manual clamp. The speed of infusion is not easy to be controlled accurately, and the workload is great.Treatment of cancer patients with chemotherapy and critically ill patients need to make drug infusion rates constant, by adjusting the input speed and duration of chemotherapy drugs is continuously injected into the uniform, not only to achieve the best effect of chemotherapy, and to minimize the side effects of chemotherapy drugs.People suffering from diabetes need to inject a certain amount of insulin at a certain speed. The previous approach is basically a large dose of insulin injection, which not only caused a huge waste, and the effect of time is relatively short, so for a conveying device of flow and velocity control, to carry a small amount of drugs and precisely control the conveying speed and flow.Some special drug delivery to the elderly, children and physical weak, such as drugs, antihypertensive drugs, sodium nitroprusside (three TPN codehydrogenase) when the infusion rate and dosage should seriously control accurately, otherwise it will have serious consequences.
- Q: How to select metering pump head?
- In metering fluoride, we recommend the use of Viton, sealed PVC pump head. For most chlorination applications, it is better to use EPDM sealed NP (plexiglass) pump head. For hydrogen peroxide mixtures, only PTFE sealed PTFE pump head or stainless steel pump head can be used
- Q: The distance from the pump button to the ground
- After confirming that the fire pump has started running, issue a command signal to the hydrant button to light the green answer light.
- Q: I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
- The pressure loss is borne by the valve. Constant pressure pumps generally do not export direct load, unless you need this load response is very fast, then the maximum displacement of the pump work, so as to ensure the rapid response of the load.
- Q: Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
- The line between the fire pump buttons should be NHBVR-4*1.5 lines. 2 start, 2 answer. Some manufacturers reported that the 3 lines can also, this need to see which is the specific equipment. In addition, we need to introduce 2 warning buses.The above lines are individually distributed
- Q: Brief description of centrifugal pump on / off operation
- Two, centrifugal pump start(1) the pump entrance valve fully open, start motor, outlet valve fully closed, fully check operation of pump.(2) when the pump outlet pressure is higher than the operation pressure, the outlet valve is gradually opened to control the flow and pressure of the pump.(3) check whether the motor current is within the rated value, such as the pump in the rated flow operation, and the motor overload should stop the pump inspection.
- Q: Does the reservoir water heater press the booster pump (high marks)?
- If insufficient pressure really, adding an automatic booster pump in the water inlet, is feasible. Home booster pump, a basic model, to sell the place to ask the next to know, generally 200 yuan or so, traffic 0.3-1.8, 90~150 watts on it. Do not buy too large, too much power, the water will also be too large, but the water heater will not be used.
- Q: Operating procedures for measuring pumps
- First, preparation and inspection before starting1. Check to make sure that the drain line is equipped with a safety valve with the correct set pressure.2. Check the screws for the liquid end parts.
- Q: How many square cables does the submersible pump for 7.5KW need?
- 7.5KW's submersible pump requires 2.5 square aluminum cables.Calculate the current value of submersible pump first: