Based on SK series, is designed specially for the use of plastics industry. Therefore, many problems have been solved, for instance: incapability to work continuously, in case of sufficient wafter to be draw-out, dirts is resulted from sewage, impossibility to restart work after long pause. It is widely used in Tubing and Molding machinery.Items:SK-0.15A、SK-0.3A、SK-0.5A、SK-0.8A、SK-1.2A、SK-2A、SK-3A,Motor power:0.55~5.5KW,extract capacity :0.15~3(m3/min),Limit vacuum:-0.095MPa。
■List of size performance
Type | electric machine power (kw) | off-gas quickresult (m3/min) | limit vacuum (Mpa) | caliber entering or excludinggas (inch) | weight (kg) | size(L×W×H) (mm) |
SK-0.15A | 0.55 | 0.15 | -0.095 | G3/4" | 14 | 380×170×220 |
SK-0.3A | 1.1 | 0.3 | -0.095 | G1" | 33 | 460×180×235 |
SK-0.5A | 1.5 | 0.5 | -0.095 | G1" | 34 | 485×180×235 |
SK-0.8A | 2.2 | 0.8 | -0.095 | G1" | 37 | 480×185×235 |
SK-1.2A | 3.0 | 1.2 | -0.095 | G1 1/2" | 51.5 | 530×220×260 |
SK-2A | 4.0 | 2.0 | -0.095 | G1 1/2" | 63 | 560×220×285 |
SK-3A | 5.5 | 3.0 | -0.095 | G2" | 105 | 645×310×325 |
■List of installation
Type | L | L1 | L2 | A | B | B2 | B3 | H | H2 | 2-d | 4-Φ | s |
SK-0.15A | 381 | 157 | 100 | 90 | 170 | 125 | 160 | 175 | 217 | G3/4" | 10 | G1/2" |
SK-0.3A | 460 | 205 | 125 | 110 | 180 | 140 | 177 | 194 | 235 | G1" | 10 | |
SK-0.5A | 485 | 228 | 125 | 110 | 180 | 140 | 177 | 194 | 235 | G1" | 10 | |
SK-0.8A | 480 | 223 | 125 | 80 | 185 | 140 | 177 | 194 | 235 | G1" | 10 | |
SK-1.2A | 528 | 240 | 140 | 110 | 218 | 160 | 197 | 213 | 260 | G1 1/2" | 12 | |
SK-2A | 560 | 265 | 140 | 110 | 220 | 190 | 234 | 234 | 286 | G1 1/2" | 12 | |
SK-3A | 645 | 305 | 140 | 150 | 310 | 216 | 272 | 327 | 323 | G2" | 12 |
- Q: Fire hydrant pump button, under what circumstances do not need to install?
- There are four things to do:Fire hydrant button to meet the requirements of national standards.In addition to pumping, it can show the location of fire.
- Q: 5 floor water pressure is too low, what kind of water pump is better?
- Installed pump flow, lift did not meet the requirements, this will need to re type selection, calculation;
- Q: There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
- Spray pump in addition to remote direct Kai, there are modules to start function, that is, on the cabinet to add control module, bus linkage pump, in addition to the pressure switch, directly pumping function, a total of three functions.
- Q: The distance from the pump button to the ground
- A button is arranged on the surface of the fire hydrant button, and when the fire hydrant is started, the press button can be pressed directly, and the red starting indicator light of the fire hydrant button is on
- Q: How to install, operate and maintain the pipeline booster pump?
- Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
- Q: What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
- The working principle of submersible pumpBefore the pump is opened, the suction pipe and pump must be filled with liquid. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet, the outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuously from the outflow discharge tube.
- Q: What is the working pressure of the hydraulic pump in the hydraulic transmission system?
- Generally speaking, for the fixed size, not limited equipment, the pressure can be selected lower, walking machinery heavy equipment pressure should be selected higher.If the load is selected, the working pressure is as follows:Load <5kN, working pressure <0.8~1MPa;Load 5~10kN, working pressure 1.5~2MPa;Load 10~20kN, working pressure 2.5~3MPa;Load 20~30kN, working pressure 3~4MPa;Load 30~50kN, working pressure 4~5MPa;Load 50kN, working pressure =5MPa;For example, the system work pressure of various machines is as follows:Grinder 0.8~2MPaModular machine tool 3~5MPaLongmen planer 2~8MPaBroaching machine 8~10MPa agricultural machinery, small construction machinery, construction machinery, hydraulic drilling machine 10~18MPa hydraulic machine, large and medium-sized excavators, heavy machinery, lifting transportation machinery 20~32MPa.
- Q: Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
- (1) the pellet dose in the safety standard of the infusion pump refers to the amount of liquid that is transported to the patient in a short period of time(two) pill dose limit is mainly to control the risk of accidental pill dosage. Especially after the mandatory requirements of pipe blockage in the elastic pipe storage liquid limit amount of agglomeration and the limitation of these methods to release pill dose.
- Q: Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
- Generally slightly lower than 0.4MPa, Zai 0.35Mpa or so, if the outlet is blocked, the outlet pressure will equal 0.4MPa
- Q: What are the failures and causes of the replacement of the fuel pump assembly?
- Gasoline pump is the gasoline from the gasoline tank suction and the gasoline tank has a certain pressure, thereby, it overcome the resistance of the pipeline, pipeline and fuel filter into the carburetor float chamber or electronically controlled injection engine in the guide frame.
Send your message to us
SK-A water ring vacuum pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords