1. Product Introduction for WQ series Designed Sewage Centrifugal Submersible Pumps
WQ series submersible sewage pump is mainly used for municipal work, industrial building, hotels, hospitals, civil air defense, mines, etc. It can be widely used in transfer waste water, rainwater and living water etc. which contains solid grains and various long fibers CNBM WQ series sewage submersible pump have many advantages, such as, hi-efficiency, circumvolution proof, blockage free, auto-coupling, hi-reliability and auto-control, etc.
2. Technical Performance of WQ series Designed Sewage Centrifugal Submersible Pumps
Discharge diameter: 50~600 mm
Capacity: 10~8000m³/h
Head: 5~60m
Power: 1.5~315kw
Diameter of pass solids: 20~145mm
3. Operation Condition of WQ series Designed Sewage Centrifugal Submersible Pumps
1). Rated Voltage: 380V(660V), Frequency: 50Hz, 3-phase AC.
2). Temperature of medium under 40ºC.
3). PH value: 4~10.
4). Volume ratio of solid in medium below 2%.
5). Density of medium should be lower than 12000kg/m³.
4. Structure Characteristic for WQ series Designed Sewage Centrifugal Submersible Pumps
WQ series submersible sewage pump is equipped with status indicator and protection device to ensure for pump safe and reliable operating.
1). The unique cable airproof is adopted, avoid leakage of cable.
2). Heat protector in stator assure of operating life of the motor.
3). The pump adopts outer recycling cooling design with motor power more than 18.5kw, which can keep the pump operating safely under the lowest water level.
4). A floating switch is installed at the bottom of motor chamber to protect the mechanical seal in the motor side.
5). The oil-water probe is installed at the up end of the oil chamber between pump and motor that can protect the mechanical seal in the side. If leakage occurs, the system will signalize and start protection.
6). Adopt perfect mechanical seal, the sealing material adopt tungsten carbide, silicon carbide and hard metal alloy, which can prevent the water from entering into the motor, and keep the operating reliable and safety.
7). The auxiliary impeller can balance the pressure outside of the mechanical seal, prevent the water entering into the oil chamber and prolong the life of the motor.
8). Unique impeller design, wide passage allow large solid and long fiber passing through freely, it features non-clog, convolve-proof and good passing ability.
9). The changeable wearing ring is installed between the impeller and the volute to keep the optimum operation conditions.
5. Impeller Design Characteristics for WQ series Designed Sewage Centrifugal Submersible Pumps
For the feculence pass freely, it must be widen the flowing passage of impeller, for the big pump, can used for double-vane, or three-vane, for the small pump, it used for single(double) flowing passage, like a bent pipe has same section, it has a good passing characteristic, avoid stop, convolve caused by slowing current possibly. The especially flowing passage of impeller, cooperate with logical volute, made the paper, soft goods, garbage bag and other material in sewage can passing freely and the pump have no vibration in the course of running-in and load through the impeller balance between dynamic and static state.
6. FAQ of CNBM Pumps
1). How long is your warranty?
Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.
2) How can I get trained on CNBM products?
Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.
3) Are your pumps cheaper than those of your competitors?
CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.
4) Do you have self-priming pumps?
Yes, our product portfolio also includes two ranges of self-priming pumps: self-priming electric pumps and self-priming side channel pumps.
5) Is it really necessary to fit a bleed valve for the boxes?
It is always best to have a bleed valve as the gas produced by the fermenting sewage is potentially hazardous.
6) If I increase the power of the motor, must I also increase the power of the inverter?
You must select the size of converter that allows maximum absorption of the electric motor.
- Q: I do pump sales ~ only to enter the line soon ~ often asked how many levels of motor? I can't recognize myself! So ask for advice here
- You can also use the motor speed divided by 50, equal to the motor series.
- Q: What is the function of open circulating water pump and shutdown in thermal power plant?
- According to the water quality difference, the purpose is to provide the corresponding cooling water, for the system oil cooler, machine seal and other cooling. Open water directly from the circulating water pipe to use, the pump is delivered to the host, the small machine oil cooler, water quality is not very high, the circulating water drainage to the back pipe, water through the water filter filter impurities. The closed water takes the self closing water tank, which is used for removing salt water. General supply pumps, water pumps, sealing cooling water, condensate pumps, sealing water, generator, hydrogen cooler and other requirements of good water quality system, closed water self circulation, and through the cooler and open water circulating water heat exchange.Thermal power plant is referred to as the thermal power plant, is the use of coal, oil and natural gas as a fuel production power plant, it is the basic production process: fuel combustion in the boiler heating water into steam, fuel chemical energy into heat energy, steam pressure and steam turbine rotation, converts heat energy into mechanical energy and steam turbine rotate the generator, the mechanical energy into electrical energy.
- Q: How many lift pumps should be used for 100 meters tall buildings?
- 35m lift around. HVAC pump lift is generally between 5~50m, the selection of the head is mainly to see the difference between water pressure. As head of 35m as an example, if the inlet height of 60m, so the theory of height =60+35=95m, if all pipe closed air conditioning water system, and resistance of the equipment for water is equal to the pressure difference is equal to the pump head to choose your height, and out of the water is the same, the resistance loss of lift all into the water. The calculated resistance loss is needed to pump lift. The resistance component (1) chiller resistance at 60-100kpa (2) water collector resistance in 120-200kpa (3) 20-50kpa (4) air terminal equipment body resistance is generally not less than 40kpa so 100m building the resistance calculation of estimated value = (1) 80kp+ (2) chiller resistance pipe, the collector resistance (140kpa+ 3) air terminal equipment 40kpa+ (4) body resistance 50kp=310kpa safety factor of 10% 320x1.1=341kpa H= P/ (head of pressure water density * acceleration of gravity g =352000/ (10m) X9.8 =34.8m fand) so we head for 35 meters
- Q: can you give me some information?
- Water pumps come in all sizes from less than one gallon per hour to over 50,000 gallons per minute. They also produce pressures on the discharge from a few inches of water to thousands of pounds per square inch. They pump water with all kinds of contaminates and chemicals dissolved in the water. Finally they can have all kinds of service conditions from a few minutes at a time once a day to continuous operation. All of these factors enter into what you need to have a good quality pump.
- Q: vw tells me the pump is defective, bad water circulation. i noticed the fans did not turn on when it began to overheat. is that irrelevant with the pump being defective? i even drop the car cold(i started the engine and drove) within 10mins it began to overheat, but the fans did not turn on. is it just the pump? the fan switch is new, no fuses are blown. the radiator and fans are less than 2 yrs old. 2000 jetta
- take the car to another mechanic as it sounds like the VW dealership doesn't know what there talking about.
- Q: 300M head of 11 stage centrifugal pump with 22KW motor, empty (not water) current of 13A, the water into the pump, current up to 44A, open the outlet valve of the current rising to 100A, immediately shut the gate current is up to 170A, the motor stop. Without any problems, not on the impeller pump shaft is not clean the shell the balance sheet, no wear, bearing normal.
- (1) the influence of the basic installation on the equipment.The quality of equipment foundation installation has great influence on the quality of equipment operation. Iron pad placed properly, causing around the foot bolt hanging device, in alignment and fastening process for iron pad hanging, tighten anchor bolts will cause deformation of crosshead slide in the crankcase, the cross head is blocked in the operation of reciprocating load increases when the chute.W5 type reciprocating vacuum pump in the structural design of the cylinder body is cylinder, and the piston, intake and exhaust valve after the heavy weight in the foundation design without considering the cylinder support or hanger, the cylinder will be in a suspended state, because the weight of the crankcase cylinder will cause deformation of the cylinder and slide and slide the concentric degree of difference, so that the cross head is blocked in the slideway and the piston reciprocating operation is blocked during the reciprocating motion in the cylinder caused by the increase of the load.According to the above analysis, inspection found that the vacuum pump end of the cylinder body is slightly lower than the end of the crankcase, cylinder pad iron is low, deformation of crosshead guide foot bolts, the cross head caused by load increases in the slideway and the piston in the cylinder reciprocating operation is blocked, this is one of the reasons causing motor overheating.(2) cylinder and valve coking;The influence of process, cylinder and valve of reciprocating pump is easy to coke, Coke will cause the piston cylinder and piston in reciprocating cylinder operation when the load increases the valve is blocked; coking will cause poor exhaust, the valve closed lax, increasing load, low vacuum degree; clearance at the cylinder piston striking the cylinder will cause coke it will increase the load of cylinder, valve has found the phenomenon of coking, which is mainly caused by the low degree of vacuum.
- Q: I have a 1997 ford ranger, during last week i noticed that the temperature started to go up, i noticed that the coolant recovery tank was empty so i added coolant and it fixed the problem, but a day later i noticed that the tank was empty again since it started to overheat again. This time i let the engine cool off and checked the radiator water levels and noticed it was dry with no water, so i added water and noticed that i was leaking from what it seems the water pump (im guessing its the water pump because is behind the engine fan, behind the belts, its hard to see), Does anyone have a possible explanation or suggestion of what i should do? Thank you i would really appreciate it.
- it sounds to me like the weep hole on the bottom of the water pump is leaking. This is what it is supposed to do when the water pump bearing gets some play. You should be able to look from under the engine and see the bottom of the water pump, it will probably look all clean as water has been running out of it. This is how you tell your water pump needs to be replaced. Generally speaking it is best to buy a NEW WATER PUMP, NOT A REMANUFACTURED OR REBUILT. The reason for this is a new water pump will last a lifetime of a vehicle generally speaking, so you only want to do this once because its a pain in the butt. and this is the time to inspect heater hoses, radiator hoses and chang the thermostat . This should solve any issues with the pump leaking, so get the front end of the truck safely up in the air, and make sure there is not a hose leaking or something simple, A shop would do a pressure test of the system and this would show them where your leak is. As a temporary measure you can leave the radiator cap loose so pressure does not build up this will keep the fluid in the vehicle, and not blow it all out the weep hole, just don't leave the cap so loose it blows off on the road somewhere, as long as water stays in, and the radiator is full you can use it.
- Q: 2 pumps in parallel, lift the same, the pump head is not stacked; 2 pumps in series, the same flow, pump head is not superimposed?.
- 2 pumps parallel, lift the same, pump head is not stacked?;Answer: the head can not be superimposed, that is, a lift and a pump, but the pumping speed (flow) is two times a taiwan.2 pumps in series, the same flow, pump head is not stacked?.Answer: the head can be superimposed, that is, the pump head is two times as much as a pump, but the pump speed is the same as that of a pump.
- Q: 1998 BMW 328i : to replace water pump, thermostat and gaskets, brake flush, fuel system cleaning with tune up,drive belt for 90k serivce; totally how much bucks?thx a lot !
- At okorder to prevent mechanics from trying to rip you on the parts.... and they might not be trying to... but their prices are higher than bav's. PS... the 90K mile service is A LOT... I have never paid anyone to do it. Look in the back of your owners manual, it tells you everything they check. I check it all myself. If you change your own oil scope things out while your under the car. It's easy to spot stuff that is wearing out. You can reset the service light yourself too. :P If you don't know anything about cars however.... don't try doing it yourself.... in other words... if you are scared of doing it, don't... if you feel confident... go for it. Also... the first time you do things it might take an hour... second time will take 30 mins... 3rd time you do something it will take 10-15 mins. Most of the projects I have done have been like that. From rebuilding the internal door mechanisms to working on the engine... that's how it's been for me. Key is to not let yourself get frustrated.
- Q: Im replacing the water pump in my 1992 toyota celica, and i cant get the pully off! i have been working hard for like an hour, i took the belts off. all i have is good old fashoned sockets and crescent wrenches. do i need to get the pully off? and is it lefty loosey and righty tighty or righty loosy lefty tighty?? because sometimes i hear they reverse it. thanks- jordan
- I think the water pump for this car is timing belt driven, and the pulley is part of the pump. Don't you have the new pump to look at? If it's not driven by the timing belt, then you remove the 4 bolts counter-clockwise, then the pulley should slide off.
Send your message to us
WQ series Designed Sewage Centrifugal Submersible Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 200 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords